Unit of competency Outline
Date retreived
22/07/2026 10:35 PM AWST
22/07/2026 10:35 PM AWST
Whilst all efforts are made to provide accurate and timely information from the relevant source/documentation, please be aware that the information supplied may not be the most current version. The accuracy of the detail has not been confirmed by the Department and therefore should not be relied upon without first confirming the contents.
Service Type A gas appliances
Service Type A gas appliances
Unit of competency
National Code
CPCPGS4002A
CPCPGS4002A
State Code
W9702
W9702
TGA Status
Replaced
Replaced
DTWD Status
Replaced
Replaced
State Implementation and Classification
Approved Date
18/08/2009
Field of Education
040327 - Plumbing
Original Release Date
18/08/2009
Nominal Hours
150
Description
Notes
Elements and Performance Criteria
No information
handling of materials
hazard control
personal protective clothing and equipment prescribed under legislation, regulations and workplace policies and practices
safe operating procedures, including recognising and preventing hazards associated with:
electrical components and safety
gas fires and explosions
hazardous materials and substances
service lines
surrounding structures and facilities
trip hazards
use of tools and equipment
work site visitors and the public
working at heights
working in proximity to others
use of firefighting equipment
use of first aid equipment
workplace environment and safety.
are badged appliances of less than 500 megajoules (MJ) for which an Australian Gas Authority (AGA) and Australian Liquefied Petroleum Gas Association (ALPGA) approval scheme exists
include:
decorative heaters
ducted heating systems
gas stoves and hot plates
hot water storage
instant hot water heaters
space heaters
mechanical components and gas appliance systems, including:
combustion chambers
heat exchangers
primary flues.
air pollution
clean-up protection
waste management.
AGA requirements
Environment Protection Authority (EPA)
internal company quality assurance policy and risk management strategy
International Standards Organisation
maintenance of Type A gas appliances complying with appropriate Australian standards
site safety plan
workplace operations and procedures.
lifting and load shifting equipment, including:
chain blocks
forklifts
hand trolleys
hoists and jacks
rollers
measuring equipment
test equipment and instruments, including:
dual probe voltage tester
manometers
multi-meters
megohmmeter
hand and power tools
spanners
wrenches.
may include:
piping materials
regulators and meters
Type A gas appliances
other approved materials
are to comply with appropriate standards for the maintenance of Type A gas appliances.
statutory electrical authority
statutory gasfitting authority
statutory plumbing authority
other relevant state or territory and local statutory authorities.
de-energised and energised tests are to include:
capacitors
electric motors
heat activated switches
ignition systems (basic, ignition and re-ignition, flame safeguard systems, hot surface ignition)
printed circuit boards
relay time delay and conventional
solenoid coils
thermistors
thermostats, direct and indirect wired
time clocks, mechanical and electronic
transformers.
dip switches
fan limit controls
fan speed settings
heat anticipators
thermostats.
burners
combination controls
fans
pilots
rail cocks, thermostats and associated components
solenoid valve regulators
thermocouples.
charts and hand drawings
diagrams or sketches and graphics
instructions issued by authorised organisational or external personnel
job drawings
manufacturer specifications and instructions
maps
material safety data sheets (MSDS)
memos
organisation work specifications and requirements
regulatory and legislative requirements, particularly those pertaining to:
building codes
OHS and environmental requirements
plumbing and gasfitting authority regulations
relevant Australian standards, including AS/NZS3000 Electrical installations, AS/NZS4836 Safe working on low-voltage electrical installations, AS5601 (AG601) Gas installations
safe work procedures relating maintaining Type A gas appliances
signage
verbal, written and graphical instructions
work bulletins
work schedules, plans and specifications.
hazard control
personal protective clothing and equipment prescribed under legislation, regulations and workplace policies and practices
safe operating procedures, including recognising and preventing hazards associated with:
electrical components and safety
gas fires and explosions
hazardous materials and substances
service lines
surrounding structures and facilities
trip hazards
use of tools and equipment
work site visitors and the public
working at heights
working in proximity to others
use of firefighting equipment
use of first aid equipment
workplace environment and safety.
are badged appliances of less than 500 megajoules (MJ) for which an Australian Gas Authority (AGA) and Australian Liquefied Petroleum Gas Association (ALPGA) approval scheme exists
include:
decorative heaters
ducted heating systems
gas stoves and hot plates
hot water storage
instant hot water heaters
space heaters
mechanical components and gas appliance systems, including:
combustion chambers
heat exchangers
primary flues.
air pollution
clean-up protection
waste management.
AGA requirements
Environment Protection Authority (EPA)
internal company quality assurance policy and risk management strategy
International Standards Organisation
maintenance of Type A gas appliances complying with appropriate Australian standards
site safety plan
workplace operations and procedures.
lifting and load shifting equipment, including:
chain blocks
forklifts
hand trolleys
hoists and jacks
rollers
measuring equipment
test equipment and instruments, including:
dual probe voltage tester
manometers
multi-meters
megohmmeter
hand and power tools
spanners
wrenches.
may include:
piping materials
regulators and meters
Type A gas appliances
other approved materials
are to comply with appropriate standards for the maintenance of Type A gas appliances.
statutory electrical authority
statutory gasfitting authority
statutory plumbing authority
other relevant state or territory and local statutory authorities.
de-energised and energised tests are to include:
capacitors
electric motors
heat activated switches
ignition systems (basic, ignition and re-ignition, flame safeguard systems, hot surface ignition)
printed circuit boards
relay time delay and conventional
solenoid coils
thermistors
thermostats, direct and indirect wired
time clocks, mechanical and electronic
transformers.
dip switches
fan limit controls
fan speed settings
heat anticipators
thermostats.
burners
combination controls
fans
pilots
rail cocks, thermostats and associated components
solenoid valve regulators
thermocouples.
charts and hand drawings
diagrams or sketches and graphics
instructions issued by authorised organisational or external personnel
job drawings
manufacturer specifications and instructions
maps
material safety data sheets (MSDS)
memos
organisation work specifications and requirements
regulatory and legislative requirements, particularly those pertaining to:
building codes
OHS and environmental requirements
plumbing and gasfitting authority regulations
relevant Australian standards, including AS/NZS3000 Electrical installations, AS/NZS4836 Safe working on low-voltage electrical installations, AS5601 (AG601) Gas installations
safe work procedures relating maintaining Type A gas appliances
signage
verbal, written and graphical instructions
work bulletins
work schedules, plans and specifications.
Overview of assessment
This unit of competency could be assessed in the workplace or a close simulation of the workplace environment providing that simulated or project-based assessment techniques fully replicate plumbing and services workplace conditions, materials, activities, responsibilities and procedures.
Critical aspects for assessment and evidence required to demonstrate competency in this unit
A person who demonstrates competency in this unit must be able to provide evidence of:
locating, interpreting and applying relevant information, standards and specifications to determine requirements and maintain Type A gas appliances
applying safety requirements throughout the work sequence, including the use of personal protective clothing and equipment, and isolation of appliances from gas and electrical services
as a minimum, the ability to perform the following servicing activities and functions:
disassembly, reassembly, testing and recommissioning of a minimum of two different Type A gas appliances
conduct evaluative tests on electrical and electronic components, including central processing units, printed circuit boards and associated parts, in order to diagnose and remedy faults and malfunctions
conduct evaluative tests on gas systems to diagnose and remedy faults and malfunctions on the mandatory components listed in the range statement
convert a Type A gas appliance to operate on another gas type, in accordance with AS5601, any local utility's requirements and manufacturer specifications
servicing activities and function should ensure:
correct selection and use of appropriate processes, tools and equipment
completion of all work to specification
compliance with regulations, standards and organisational quality procedures and processes
communicating and working effectively and safely with others.
Context of and specific resources for assessment
This competency is to be assessed using standard and authorised work practices, safety requirements and environmental constraints.
Assessment of essential underpinning knowledge will usually be conducted in an off-site context.
Assessment is to comply with relevant regulatory or Australian standards' requirements.
Resource implications for assessment include:
an induction procedure and requirement
realistic tasks or simulated tasks covering the mandatory task requirements
relevant specifications and work instructions
tools and equipment appropriate to applying safe work practices
support materials appropriate to activity
workplace instructions relating to safe working practices and addressing hazards and emergencies
material safety data sheets
research resources, including industry related systems information.
Reasonable adjustments for people with disabilities must be made to assessment processes where required. This could include access to modified equipment and other physical resources, and the provision of appropriate assessment support.
Method of assessment
Assessment methods must:
satisfy the endorsed Assessment Guidelines of the Construction, Plumbing and Services Integrated Framework Training Package
include direct observation of tasks in real or simulated work conditions, with questioning to confirm the ability to consistently identify and correctly interpret the essential underpinning knowledge required for practical application
reinforce the integration of employability skills with workplace tasks and job roles
confirm that competency is verified and able to be transferred to other circumstances and environments.
Validity and sufficiency of evidence requires that:
competency will need to be demonstrated over a period of time reflecting the scope of the role and the practical requirements of the workplace
where the assessment is part of a structured learning experience the evidence collected must relate to a number of performances assessed at different points in time and separated by further learning and practice, with a decision on competency only taken at the point when the assessor has complete confidence in the person's demonstrated ability and applied knowledge
all assessment that is part of a structured learning experience must include a combination of direct, indirect and supplementary evidence.
Assessment processes and techniques should as far as is practical take into account the language, literacy and numeracy capacity of the candidate in relation to the competency being assessed.
Supplementary evidence of competency may be obtained from relevant authenticated documentation from third parties, such as existing supervisors, team leaders or specialist training staff.
This unit of competency could be assessed in the workplace or a close simulation of the workplace environment providing that simulated or project-based assessment techniques fully replicate plumbing and services workplace conditions, materials, activities, responsibilities and procedures.
Critical aspects for assessment and evidence required to demonstrate competency in this unit
A person who demonstrates competency in this unit must be able to provide evidence of:
locating, interpreting and applying relevant information, standards and specifications to determine requirements and maintain Type A gas appliances
applying safety requirements throughout the work sequence, including the use of personal protective clothing and equipment, and isolation of appliances from gas and electrical services
as a minimum, the ability to perform the following servicing activities and functions:
disassembly, reassembly, testing and recommissioning of a minimum of two different Type A gas appliances
conduct evaluative tests on electrical and electronic components, including central processing units, printed circuit boards and associated parts, in order to diagnose and remedy faults and malfunctions
conduct evaluative tests on gas systems to diagnose and remedy faults and malfunctions on the mandatory components listed in the range statement
convert a Type A gas appliance to operate on another gas type, in accordance with AS5601, any local utility's requirements and manufacturer specifications
servicing activities and function should ensure:
correct selection and use of appropriate processes, tools and equipment
completion of all work to specification
compliance with regulations, standards and organisational quality procedures and processes
communicating and working effectively and safely with others.
Context of and specific resources for assessment
This competency is to be assessed using standard and authorised work practices, safety requirements and environmental constraints.
Assessment of essential underpinning knowledge will usually be conducted in an off-site context.
Assessment is to comply with relevant regulatory or Australian standards' requirements.
Resource implications for assessment include:
an induction procedure and requirement
realistic tasks or simulated tasks covering the mandatory task requirements
relevant specifications and work instructions
tools and equipment appropriate to applying safe work practices
support materials appropriate to activity
workplace instructions relating to safe working practices and addressing hazards and emergencies
material safety data sheets
research resources, including industry related systems information.
Reasonable adjustments for people with disabilities must be made to assessment processes where required. This could include access to modified equipment and other physical resources, and the provision of appropriate assessment support.
Method of assessment
Assessment methods must:
satisfy the endorsed Assessment Guidelines of the Construction, Plumbing and Services Integrated Framework Training Package
include direct observation of tasks in real or simulated work conditions, with questioning to confirm the ability to consistently identify and correctly interpret the essential underpinning knowledge required for practical application
reinforce the integration of employability skills with workplace tasks and job roles
confirm that competency is verified and able to be transferred to other circumstances and environments.
Validity and sufficiency of evidence requires that:
competency will need to be demonstrated over a period of time reflecting the scope of the role and the practical requirements of the workplace
where the assessment is part of a structured learning experience the evidence collected must relate to a number of performances assessed at different points in time and separated by further learning and practice, with a decision on competency only taken at the point when the assessor has complete confidence in the person's demonstrated ability and applied knowledge
all assessment that is part of a structured learning experience must include a combination of direct, indirect and supplementary evidence.
Assessment processes and techniques should as far as is practical take into account the language, literacy and numeracy capacity of the candidate in relation to the competency being assessed.
Supplementary evidence of competency may be obtained from relevant authenticated documentation from third parties, such as existing supervisors, team leaders or specialist training staff.
Replaces
| State Code | National Code | Title | Type |
|---|---|---|---|
| W2792 | BCPGS4002A | Service Type A gas appliances | Unit of competency |
Replaced By
| State Code | National Code | Title | Type |
|---|---|---|---|
| D7464 | CPCPGS4012A | Service Type A gas appliances | Unit of competency |
| State Code | National Code | Title | Type |
|---|---|---|---|
| W603 | CPC32708 | Certificate III in Gas Fitting | Qualification |