Unit of competency Outline

Date retreived
22/07/2026 8:34 AM AWST

Whilst all efforts are made to provide accurate and timely information from the relevant source/documentation, please be aware that the information supplied may not be the most current version. The accuracy of the detail has not been confirmed by the Department and therefore should not be relied upon without first confirming the contents.

Maintain and fit oxygen masks

Maintain and fit oxygen masks

Unit of competency
National Code
MEA504A
State Code
D4500
TGA Status
Replaced
DTWD Status
Replaced
Current Release Number
2.00
Current Release Date
23/01/2012
State Implementation and Classification
Approved Date
17/06/2014
Field of Education
061301 - Occupational Health And Safety
Original Release Date
17/06/2014
Nominal Hours
30
Description
This unit of competency is part of the Aeroskills Life Support and Furnishing Certificate III and IV training pathways. It covers the competencies required to maintain and fit oxygen masks worn by aviation aircrew. Maintenance involves inspecting, testing, isolating faults, replacing parts, cleaning and testing prior to placing the item back in service. Fitting an oxygen mask includes adjusting the mask to fit the individual (oxygen masks are not an off-the-shelf issue). This unit is used in workplaces that operate under the airworthiness regulatory systems of the ADF and CASA.This unit is equivalent to PUADEFLS004B Maintain and fit oxygen masks.
Notes
Elements and Performance Criteria
1. Maintain oxygen mask
  • 1.1. Oxygen mask is inspected for serviceability in accordance with standard procedures
  • 1.2. Oxygen mask is tested for serviceability in accordance with standard procedures and manufacturer's specifications
  • 1.3. Identified faults beyond own authority to rectify are reported to supervisor and faulty oxygen mask is quarantined
  • 1.4. Unserviceable parts of the oxygen mask are replaced in accordance with standards procedures
  • 1.5. Communication system components are tested in accordance with standard procedures
  • 1.6. Oxygen mask is cleaned in accordance with standard procedures
  • 1.7. Oxygen mask is presented for inspection by supervisor in accordance with standard procedures
  • 1.8. Maintenance documentation is completed and processed in accordance with standard enterprise procedures
2. Fit oxygen mask
  • 2.1. Fitting process is explained to the participant so that optimal fit can be achieved through relevant feedback
  • 2.2. Participant is measured to select an appropriate size oxygen mask
  • 2.3. Components of oxygen mask are adjusted to optimise fit
  • 2.4. Integration of the oxygen mask and helmet is confirmed for correct function during operations
  • 2.5. Oxygen mask fit is verified through participant feedback and by the supervisor
  • 2.6. Relevant documentation is completed and processed in accordance with standard enterprise procedures
The range statement relates to the unit of competency as a whole. It allows for different work environments and situations that may affect performance. Bold italicised wording, if used in the performance criteria, is detailed below. Essential operating conditions that may be present with training and assessment (depending on the work situation, needs of the candidate, accessibility of the item, and local industry and regional contexts) may also be included.
Standard procedures
Standard procedures may be found in any or all of:
state/territory/Commonwealth OHS legislation, regulations and codes
Australian Standards
equipment manufacturers' specifications and procedures
industry practices
safety manual
maintenance schedules
work instructions
maintenance organisation manual
MSDS
Defence regulations and instructions
standing instructions
Faults
Faults may include:
contamination
corrosion
cracks
excessive wearing
fraying
incorrect manufacture
intermittent communication
leaks
perishing
Parts of the oxygen mask
Parts of the oxygen mask may include:
communication system (e.g. microphone)
delivery tube
exo-skeleton (e.g. outer shell)
face piece (e.g. may include trimming)
retention system (e.g. strap)
valves
Communication system components
Communication system components may include:
microphone
electric cables
switches
Adjustable components
Components may include:
retention system (e.g. strap)
seals
Application
Application of this unit may relate to:
scheduled or unscheduled maintenance activities
individual or team-related activities
The Evidence Guide provides advice on assessment and must be read in conjunction with the performance criteria, required skills and knowledge, range statement and the Assessment Guidelines for the Training Package.
Overview of assessment
A person who demonstrates competency in this unit must be able to maintain and fit oxygen masks while observing all relevant safety precautions, especially those relating to oxygen.
Critical aspects for assessment and evidence required to demonstrate competency in this unit
The underlying skills inherent in this unit should be transferable across a range of aircraft life support equipment maintenance activities. It is essential that oxygen mask testing and inspection procedures, cleanliness requirements and safety precautions are fully observed, understood and complied with. Ability to interpret maintenance and fitting procedures and apply them in practice is critical.
Evidence of transferability of skills and knowledge related to oxygen mask maintenance and fitting is essential. This is to be demonstrated through demonstration of the ability to recognise faults and damage and perform appropriate repairs that are within the bounds of the individual's authority, and through the demonstration of correct fitting procedures. The work plan should take account of applicable safety and quality requirements in accordance with the industry and regulatory standards.
A person cannot be assessed as competent until it can be demonstrated to the satisfaction of the workplace assessor that the relevant elements of the unit of competency are being achieved under routine supervision on at least three (3) unserviceable oxygen masks providing a representative range of maintenance tasks and on the correct fitting of oxygen masks to at least three individuals. This shall be established via the records in the Log of Industrial Experience and Achievement or, where appropriate, an equivalent Industry Evidence Guide.
Context of and specific resources for assessment
Competency should be assessed in the workplace or simulated workplace using materials, tools and equipment specified in the maintenance manuals and applicable procedures. It is also expected that general and special purpose tools and ground support equipment would be used where appropriate.
Method of assessment

Guidance information for assessment
Replaced By
State Code National Code Title Type
AUE14 MEA504 Maintain and fit oxygen masks Unit of competency