Unit of competency Outline

Date retreived
22/07/2026 11:11 AM AWST

Whilst all efforts are made to provide accurate and timely information from the relevant source/documentation, please be aware that the information supplied may not be the most current version. The accuracy of the detail has not been confirmed by the Department and therefore should not be relied upon without first confirming the contents.

Plan and coordinate boiler operations

Plan and coordinate boiler operations

Unit of competency
National Code
FWPCOT4206
State Code
AXK91
TGA Status
Replaced
DTWD Status
Replaced
Current Release Number
1.00
Current Release Date
13/05/2016
State Implementation and Classification
Approved Date
05/10/2016
Field of Education
030717 - Plant And Machine Operations
Original Release Date
05/10/2016
Nominal Hours
60
Description
This unit of competency describes the outcomes required to plan the operation of a steam generated boiler and to coordinate boiler operating personnel to startup, operate, shutdown, clean and store the boiler. The unit applies to boiler plant operators in a timber treatment plant setting and also involves monitoring and adjusting boiler performance.No licensing, legislative, regulatory, or certification requirements apply to this unit at the time of publication.
Notes
Elements and Performance Criteria
1. Plan boiler operation
  • 1.1 Interpret requirements for the allocated process to calculate steam generation levels.
  • 1.2 Plan and document operational orders and schedules to meet production requirements.
  • 1.3 Plan boiler startup, operation and shutdown in line with production requirements.
  • 1.4 Communicate all information to operators in line with organisational procedures.
2. Coordinate boiler startup and operation
  • 2.1 Check boiler house chemicals for correct labelling to ensure compliance with safety, and regulatory requirements.
  • 2.2 Direct operator processes for completing pre-operational safety and pre start-up checks.
  • 2.3 Monitor boiler startup for correct running conditions and sign on.
  • 2.4 Routinely check continued operation and condition of boiler with operators and assist them to evaluate boiler data and performance.
  • 2.5 Modify generation levels to ensure optimum performance and communicate changes to operators.
  • 2.6 Diagnose problematic boiler operations, calculate required adjustments and communicate to operators.
  • 2.7 Monitor and evaluate boiler operations and output to determine process improvements.
  • 2.8 Direct emergency shutdown processes in cases of fire.
3. Coordinate boiler shutdown, storage and records
  • 3.1 Direct operator processes for shutting down equipment and ensure compliance with organisational safety procedures.
  • 3.2 Check removal of valves and fittings and inspect boiler.
  • 3.3 Assess boiler condition, direct operator cleaning processes and ensure compliance with environmental protection practices.
  • 3.4 Select storage mode and direct operators to store boiler in line with organisational procedures.
  • 3.5 Obtain operating logs and fuel efficiency records from operators and complete operating calculations.
  • 3.6 Document and report operational records, equipment faults and process improvement recommendations to appropriate personnel.
No information
No information
Replaces
State Code National Code Title Type
D5968 FPICOT4206B Plan and coordinate boiler operations Unit of competency
Replaced By
State Code National Code Title Type
OFD20 FWPCOT3334 Conduct steam boiler operations Unit of competency
State Code National Code Title Type
BAL4 FWP50116 Diploma of Forest and Forest Products Qualification
BAL9 FWP40216 Certificate IV in Timber Processing Qualification