Unit of competency Outline

Date retreived
22/07/2026 4:45 PM AWST

Whilst all efforts are made to provide accurate and timely information from the relevant source/documentation, please be aware that the information supplied may not be the most current version. The accuracy of the detail has not been confirmed by the Department and therefore should not be relied upon without first confirming the contents.

Monitor and control drainage operations

Monitor and control drainage operations

Unit of competency
National Code
NWP332B
State Code
D1910
TGA Status
Replaced
DTWD Status
Replaced
Current Release Number
2.00
Current Release Date
30/04/2012
State Implementation and Classification
Approved Date
14/01/2009
Field of Education
030907 - Water And Sanitary Engineering
Original Release Date
14/01/2009
Nominal Hours
30
Description
This unit of competency describes the outcomes required to monitor, operate and control drainage systems. The ability to identify faults, gather data, interpret technical information and operate technical equipment are essential to performance.
Notes
Elements and Performance Criteria
1Inspect drainage systems.
  • 1.1 Schedule and conduct routine inspections of drainage systems and monitor fault reports according to organisational and statutory requirements.
  • 1.2 Collect, analyse and report data on drainage system performance and usage according to organisational and statutory requirements.
  • 1.3 Control water sample collecting and recording according to organisational procedures.
  • 1.4 Monitor and maintain water according to organisational requirements.
  • 1.5 Correctly select, fit and use required safety equipment, including personal protective equipment.
2Regulate flows.
  • 2.1 Inspect flow regulating systems and apply adjustments necessary to achieve discharge requirements.
  • 2.2 Monitor discharge flows and apply diversions required to facilitate repair or emergency.
3Control and operate processes.
  • 3.1 Control processes to maintain parameters of operation.
  • 3.2 Identify, address and report problems and operational conditions of the drainage network according to organisational requirements.
  • 3.3 Integrate processes to improve drainage network performance according to organisational requirements.
4. Compile process records.
  • 4.1 Maintain workplace records according to organisational and statutory requirements.
The range statement relates to the unit of competency as a whole. It allows for different work environments and situations that may affect performance. Bold italicised wording, if used in the Performance Criteria, is detailed below. Add any essential operating conditions that may be present with training and assessment depending on the work situation, needs if the candidate, accessibility of the item, and local industry and regional contexts.
Drainage systems may include:
urban and rural locations
pumping stations
discharge outlets
drainage inlets
open channel and canal systems
Organisational and statutory requirements may include:
by-laws and organisational policies
standard operating procedures
environment protection
equal employment opportunity
occupational health and safety, including use of personal protective equipment
electrical and mechanical procedures
dangerous goods
World Health Organisation and National Health and Medical Research Council (NHMRC) guidelines
Flow regulating systems may include:
pumping systems
valving systems
gravity systems
emergency overflow and diversion systems
metered pits
flow chambers
control systems
The evidence guide provides advice on assessment and must be read in conjunction with the Performance Criteria, Required Skills and Knowledge, the Range Statement and the Assessment Guidelines for the Training Package.
Critical aspects for assessment and evidence required to demonstrate competency in this unit
The candidate should demonstrate the ability to monitor, operate and control drainage systems including:
monitoring fault reports
scheduling and conducting inspections
collecting performance and usage data
collecting samples
monitoring water quality
inspecting and adjusting flow regulating systems
monitoring discharge flows
applying diversions as required
controlling and integrating processes
identifying and addressing problems
completing required documentation
Context of and specific resources for assessment
Access to the workplace and resources including:
documentation that should normally be available in a water industry organisation
relevant codes, standards, and government regulations
Where applicable, physical resources should include equipment modified for people with disabilities.
Access must be provided to appropriate learning and/or assessment support when required.
Assessment processes and techniques must be culturally appropriate, and appropriate to the language and literacy capacity of the candidate and the work being performed.
Validity and sufficiency of evidence requires that:
competency will need to be demonstrated over a period of time reflecting the scope of the role and the practical requirements of the workplace
where the assessment is part of a structured learning experience the evidence collected must relate to a number of performances assessed at different points in time and separated by further learning and practice
a decision of competence only taken at the point when the assessor has complete confidence in the person's competence over time and in various contexts
all assessment that is part of a structured learning experience must include a combination of direct, indirect and supplementary evidence
where assessment is for the purpose of recognition (RCC/RPL), the evidence provided will need to be authenticated and show that it represents competency demonstrated over a period of time
assessment can be through simulated project-based activity and must include evidence relating to each of the elements in this unit
In all cases where practical assessment is used it will be combined with targeted questioning to assess the underpinning knowledge. Questioning will be undertaken in a manner appropriate to the skill levels of the operator, any cultural issues that may affect responses to the questions, and reflecting the requirements of the competency and the work being performed.
Replaces
State Code National Code Title Type
M1914 NWP332A Monitor and control drainage operations Unit of competency
Replaced By
State Code National Code Title Type
AVZ00 NWPIRR031 Monitor and control drainage operations Unit of competency
State Code National Code Title Type
D245 NWP30107 Certificate III in Water Operations Qualification