Whilst all efforts are made to provide accurate and timely information from the relevant source/documentation, please be aware that the information supplied may not be the most current version. The accuracy of the detail has not been confirmed by the Department and therefore should not be relied upon without first confirming the contents.
Survey waterproofing systems
Survey waterproofing systems
Unit of competency
National Code
CPCCWP5006
CPCCWP5006
State Code
OEK94
OEK94
TGA Status
Current
Current
DTWD Status
Approved
Approved
State Implementation and Classification
Approved Date
06/04/2023
Field of Education
040305 - Building Surveying
Original Release Date
06/04/2023
Nominal Hours
70
Description
This unit of competency specifies the skills and knowledge required to conduct a survey of waterproofing systems and remedial recommendations for buildings. The unit applies to Class 1 and 10 Buildings, and Class 2 to 9 Buildings.The unit covers planning and preparing to conduct a survey of waterproofing systems, carrying out the survey of waterproofing systems, analysing report findings and making recommendations, and evaluating and communicating survey findings. The unit is suitable for builders, building supervisors, building surveyors, building designers, architects, waterproofing design specialists, waterproofing supervisors, and consultants, engineers or other design specialists. Licensing, legislative, regulatory or certification requirements may apply to this unit. Relevant work health and safety (WHS) state and territory regulatory authorities should be consulted to confirm jurisdictional requirements.
Notes
Elements and Performance Criteria
1. Plan and prepare.
- 1.1 Determine scope of survey in consultation with stakeholders, reports and project brief, building works or structural specifications.
- 1.2 Gather and review design specifications and data sheets, manufacturers’ information, drawings and waterproofing contractors’ scopes of work.
- 1.3 Assess site environmental conditions according to approved plans, including surface and sub-surface drainage.
- 1.4 Confirm design complies with National Construction Code (NCC) performance requirements and Australian Standards.
- 1.5 Determine tools, equipment and relevant technologies required for the survey according to site conditions.
- 1.6 Develop the scope for the survey, including installation stages and compliance review.
2. Carry out survey.
- 2.1 Establish stage inspection protocols and benchmarks for compliance with design and manufacturers’ specifications.
- 2.2 Communicate survey procedures and timeframe in consultation with stakeholders.
- 2.3 Conduct quality assurance inspections of the waterproofing systems, including substrate assessment for suitability, component installation and compliance with manufacturers’ specifications.
- 2.4 Identify latent conditions outside of the waterproofing system design.
- 2.5 Determine if installation complies with design requirements and manufacturers’ specifications.
- 2.6 Record observations of survey of waterproofing systems for analysis.
3. Analyse survey report findings and make recommendations.
- 3.1 Review report findings and confirm installation complies with manufacturer’s specifications, Australian Standards and NCC performance requirements.
- 3.2 Identify and document any non-compliance regarding installation and deviation from design.
- 3.3 Develop recommendations for remediation of non-compliances and any defects.
- 3.4 Develop recommendations to remediate the latent conditions to assist with the remediation advice.
- 3.5 Develop a report summary and quality control recommendations for stakeholders.
4. Evaluate survey findings and communicate recommendations.
- 4.1 Review survey findings against waterproofing systems design.
- 4.2 Review and confirm remediation of non-compliances and defects, including latent conditions.
- 4.3 Review survey results to accommodate use of area at the highest risk level.
- 4.4 Communicate survey findings and any recommendations to stakeholders.
No information
No information
No information
| State Code | National Code | Title | Type |
|---|---|---|---|
| BIJ4 | CPC50722 | Diploma of Construction Waterproofing Design and Survey | Qualification |
| AF020 | CPCSS00011 | Design and Survey Waterproofing Skill Set | Skill set |