Whilst all efforts are made to provide accurate and timely information from the relevant source/documentation, please be aware that the information supplied may not be the most current version. The accuracy of the detail has not been confirmed by the Department and therefore should not be relied upon without first confirming the contents.

Install water pump sets

Install water pump sets

Unit of competency
National Code
CPCPWT3015A
State Code
D7503
TGA Status
Replaced
DTWD Status
Replaced
Current Release Number
1.00
Current Release Date
19/05/2011
State Implementation and Classification
Approved Date
10/07/2012
Field of Education
040327 - Plumbing
Original Release Date
10/07/2012
Nominal Hours
8
Description
This unit of competency specifies the outcomes required to install and test water pumps.
Notes
Elements and Performance Criteria
1. Prepare for work.
  • 1.1. Drawings and specifications are obtained.
  • 1.2. Safety (OHS) requirements associated with installing water pump sets, and workplace environmental requirements, are adhered to throughout the work.
  • 1.3. Quality assurance requirements are identified and adhered to in accordance with workplace requirements.
  • 1.4. Tasks are planned and sequenced in conjunction with others involved in or affected by the work and statutory and regulatory authority requirements.
  • 1.5. Tools and equipment for installing water pump sets, including personal protective equipment, are selected and checked for serviceability.
  • 1.6. Work area is prepared to support efficient installation of water pump sets.
2. Identify installation requirements.
  • 2.1. Location of pump is determined following site inspection.
  • 2.2. Pump base requirements are identified from drawings and specifications using relevant information.
  • 2.3. Required materials and equipment are identified, ordered and collected in accordance with workplace procedures.
  • 2.4. Materials and equipment are checked for compliance with relevant Australian standards, docket and order form, and for acceptable condition.
  • 2.5. Sustainability principles and concepts are applied to work preparation and application.
3. Install water pump sets.
  • 3.1. Pump base is set out to comply with drawings and specifications.
  • 3.2. Pump base is constructed in accordance with drawings and specifications.
  • 3.3. Pump and pump controls are installed in accordance with relevant Australian standards, drawings, specifications and manufacturer instructions.
  • 3.4. Fuel tank fitting, alignment of shafts and couplings, and the use of mechanical joints comply with relevant specifications and manufacturer instructions.
  • 3.5. Pressure testing of piping system is conducted in accordance with specifications.
  • 3.6. Pump set is tested in accordance with specifications and test data is recorded in required format.
4. Clean up.
  • 4.1. Work area is cleared and materials disposed of, reused or recycled according to legislation, regulations, codes of practice and job specification.
  • 4.2. Tools and equipment are cleaned, checked, maintained and stored in accordance with manufacturer recommendations and workplace procedures.
  • 4.3. Documentation is completed in accordance with workplace requirements.
RANGE STATEMENT
The range statement relates to the unit of competency as a whole. It allows for different work environments and situations that may affect performance. Bold italicised wording, if used in the performance criteria, is detailed below. Essential operating conditions that may be present with training and assessment (depending on the work situation, needs of the candidate, accessibility of the item, and local industry and regional contexts) may also be included.
Safety (OHS) is to be in accordance with commonwealth, state and territory legislation and regulations and may include:
handling of materials
hazard control
personal protective clothing and equipment prescribed under legislation, regulations and workplace policies and practices
safe operating procedures, including recognising and preventing hazards associated with:
electricity
hazardous materials and substances
other machines
surrounding structure and facilities
trip hazards
underground services
use of tools and equipment
work site visitors and the public
working at heights
working in confined spaces
working in proximity to others
use of firefighting equipment
use of first aid equipment
workplace environment and safety.
Environmental requirements cover water quality management and may include:
clean-up protection
stormwater protection
waste management.
Quality assurance requirements may include:
Environment Protection Authority (EPA)
environment policy
internal company quality assurance policy and risk management strategy
International Standards Organisation
site safety plan
workplace operations and procedures.
Statutory and regulatory authorities include:
commonwealth, state and local authorities administering applicable Acts, regulations and codes of practice..
Tools and equipment may include:
chain blocks
concreting tools
forklifts
hand and power tools
hand trolleys
hoists and jacks
lifting and load shifting equipment
measuring and alignment tools
rollers.
Water pump sets:
may include:
multi-stage turbine
positive displacement
submersible and electric and compression ignition driven pumps
may be:
belt driven by an electric or petrol and diesel motor
close coupled
long coupled with mechanical joints.
Information may include:
charts and hand drawings
diagrams or sketches
instructions issued by authorised organisational or external personnel
job drawings
manufacturer specifications and instructions
material safety data sheets (MSDS)
memos
organisation work specifications and requirements
regulatory and legislative requirements, particularly those pertaining to:
building codes
OHS and environmental requirements
plumbing regulations
relevant Australian standards
safe work procedures relating to installing water pump sets
signage
verbal, written and graphical instructions
work bulletins
work schedules, plans and specifications.
Materials may include:
circulating
hydropneumatic pumping systems and fittings
spa baths
water pump sets.
Sustainability principles and concepts:
cover the current and future social, economic and environmental use of resources
may include:
appropriate material selection that has minimal environmental impact
efficient use and recycling of material
efficient energy and water use
disposal of waste material to ensure minimal environmental impact.
Pump controls may be:
automatic controls, which may be float, level or flow switches
manual.
EVIDENCE GUIDE
The evidence guide provides advice on assessment and must be read in conjunction with the performance criteria, required skills and knowledge, range statement and the Assessment Guidelines for the Training Package.
Overview of assessment
This unit of competency could be assessed in the workplace or a close simulation of the workplace environment providing that simulated or project-based assessment techniques fully replicate plumbing and services workplace conditions, materials, activities, responsibilities and procedures.
Critical aspects for assessment and evidence required to demonstrate competency in this unit
A person who demonstrates competency in this unit must be able to provide evidence of:
locating, interpreting and applying relevant information, Australian standards and specifications to install water pump sets
applying safety requirements throughout the work sequence, including electrical requirements and the use of personal protective clothing and equipment
as a minimum the ability to, given the plans and specifications, plan the layout, and then install and test a centrifugal pump, ensuring:
correct identification of location, design and details of proposed installations
correct selection and use of appropriate processes, tools and equipment
completing all work to specification
compliance with regulations, relevant Australian standards and organisational quality procedures and processes
application of sustainability principles and concepts
communicating and working effectively and safely with others.
Context of and specific resources for assessment
This competency is to be assessed using standard and authorised work practices, safety requirements and environmental constraints.
Assessment of essential underpinning knowledge will usually be conducted in an off-site context.
Assessment is to comply with relevant regulatory or Australian standards' requirements.
Resource implications for assessment include:
an induction procedure and requirement
realistic tasks or simulated tasks covering the minimum task requirements
relevant specifications and work instructions
tools and equipment appropriate to applying safe work practices
support materials appropriate to activity
workplace instructions relating to safe working practices and addressing hazards and emergencies
material safety data sheets
research resources, including industry related systems information.
Reasonable adjustments for people with disabilities must be made to assessment processes where required. This could include access to modified equipment and other physical resources, and the provision of appropriate assessment support.
Method of assessment
Assessment methods must:
satisfy the endorsed Assessment Guidelines of the Construction, Plumbing and Services Training Package
include direct observation of tasks in real or simulated work conditions, with questioning to confirm the ability to consistently identify and correctly interpret the essential underpinning knowledge required for practical application
reinforce the integration of employability skills with workplace tasks and job roles
confirm that competency is verified and able to be transferred to other circumstances and environments.
Validity and sufficiency of evidence requires that:
competency will need to be demonstrated over a period of time reflecting the scope of the role and the practical requirements of the workplace
where the assessment is part of a structured learning experience the evidence collected must relate to a number of performances assessed at different points in time and separated by further learning and practice, with a decision on competency only taken at the point when the assessor has complete confidence in the person's demonstrated ability and applied knowledge
all assessment that is part of a structured learning experience must include a combination of direct, indirect and supplementary evidence.
Assessment processes and techniques should as far as is practical take into account the language, literacy and numeracy capacity of the candidate in relation to the competency being assessed.
Supplementary evidence of competency may be obtained from relevant authenticated documentation from third parties, such as existing supervisors, team leaders or specialist training staff.
Replaces
State Code National Code Title Type
W9762 CPCPWT3005A Install water pump sets Unit of competency
Replaced By
State Code National Code Title Type
WF969 CPCPWT3025A Install water pumpsets Unit of competency
State Code National Code Title Type
D415 CPC32811 Certificate III in Fire Protection Qualification
D411 CPC32411 Certificate III in Plumbing Qualification
D389 CPC20911 Certificate II in Urban Irrigation Qualification