Whilst all efforts are made to provide accurate and timely information from the relevant source/documentation, please be aware that the information supplied may not be the most current version. The accuracy of the detail has not been confirmed by the Department and therefore should not be relied upon without first confirming the contents.

Perform rescue from a live low voltage panel

Perform rescue from a live low voltage panel

Unit of competency
National Code
UETDRMP007
State Code
BHA06
TGA Status
Replaced
DTWD Status
Transition (Replaced)
Current Release Number
1.00
Current Release Date
14/10/2022
State Implementation and Classification
Approved Date
Field of Education
061301 - Occupational Health And Safety
Original Release Date
Nominal Hours
Description
This unit involves the skills and knowledge required to perform a rescue from live low voltage (LV) electrical apparatus in an electricity supply industry (ESI) environment. This does not include overhead lines and underground cables.It includes the organisational workplace requirements for the inspection and use of live LV panel rescue equipment, and how it applies to ESI workers to meet work health and safety (WHS)/occupational health and safety (OHS), mobility and mutual aid requirements.Note: Those holding an existing ESI or Electrotechnology qualification or equivalent meet the prerequisite unit requirements.Refer to the UET Transmission, Distribution and Rail Sector Training PackageCompanion Volume Implementation Guide for equivalency definition.The application of the skills and knowledge described in this unit may require a licence/registration to practice in the workplace.Other conditions may also apply under state and territory legislative and regulatory licensing requirements which must be confirmed prior to commencing this unit.
Notes
Elements and Performance Criteria
1 Prepare to perform rescue procedures from live LV panel
  • 1.1 Workplace requirements for the rescue are identified and confirmed
  • 1.2 Electricity isolation point is identified
  • 1.3 Rescue equipment including personal protective equipment (PPE) is obtained and inspected in accordance with workplace requirements
2 Carry out rescue from live LV panel
  • 2.1 Situation is assessed, and rescue response is activated in accordance with workplace requirements
  • 2.2 Casualty is removed from the live LV panel in accordance with workplace requirements
3 Complete the LV panel rescue procedure
  • 3.1 Casualty is assessed in accordance with workplace requirements
  • 3.2 Incident site is secured and entry controlled in accordance with workplace requirements
  • 3.3 Incident is reported in accordance with workplace requirements
No information
No information
Replaces
State Code National Code Title Type
ODM51 UETDRRF004 Perform rescue from a live LV panel Unit of competency
Replaced By
State Code National Code Title Type
OFH09 UETDRMP018 Perform rescue from a live low voltage panel Unit of competency