Unit of competency Outline
Date retreived
23/07/2026 6:58 AM AWST
23/07/2026 6:58 AM AWST
Whilst all efforts are made to provide accurate and timely information from the relevant source/documentation, please be aware that the information supplied may not be the most current version. The accuracy of the detail has not been confirmed by the Department and therefore should not be relied upon without first confirming the contents.
Fabricate and install residential windows and doors
Fabricate and install residential windows and doors
Unit of competency
National Code
LMFGG3016B
LMFGG3016B
State Code
W8690
W8690
TGA Status
Deleted
Deleted
DTWD Status
Deleted
Deleted
State Implementation and Classification
Approved Date
11/06/2010
Field of Education
040323 - Glazing
Original Release Date
11/06/2010
Nominal Hours
40
Description
This unit addresses the knowledge and skills required to plan, fabricate and install residential windows and doors.
Notes
Elements and Performance Criteria
1. Plan for work
- 1.1. Work requirements in the form of type of window or door to be fabricated and installed are identified from work instructions. This includes the identification of its pattern or plan
- 1.2. Workplace health and safety requirements for fabrication and installation of windows and doors including personal protection needs, are observed throughout the work
- 1.3. The process for fabricating and installing windows and doors is identified
- 1.4. Types and quantities of materials required are calculated from plans or work instructions or by measuring the fixture opening in accordance with Australian Standards and industry practice
- 1.5. Cutting lists are prepared from plans, work instructions or measurements of opening to suit the window or door to be installed
- 1.6. Fittings, fixings and joining devices or materials are selected in line with specifications or type of materials to be joined or fixed and Australian standards
- 1.7. Tools and equipment appropriate to the fixing method are identified
2. Prepare for work
- 2.1. Work sequence is determined in a logical order to suit the job
- 2.2. Tools, equipment and materials are selected and checked prior to use to ensure that they are appropriate for the work, serviceable and in a safe condition
- 2.3. Components of the window or door are checked against specifications or job order for: size, quantity, finish and profile
3. Fabricate and install window or door
- 3.1. Materials are measured and marked to cutting list requirements and most economical use of materials
- 3.2. Materials are cut to cutting list requirements in accordance with workplace procedures or industry practice
- 3.3. Components of window or door are assembled in accordance with recognised industry standards
- 3.4. Fittings are installed to window or door in accordance with workplace procedures or industry practice
- 3.5. Window or door is installed in opening using appropriate fixing method in accordance with recognised industry standard
4. Complete work
- 4.1. Installed window or door is inspected for quality of work and repaired, re-fabricated or re-installed as required in accordance with workplace procedures
- 4.2. Material which can be re-used is collected and stored
- 4.3. Waste and scrap material is removed for disposal or recycling as required
- 4.4. Work area is cleaned and rubbish disposed of as appropriate
- 4.5. Tools, equipment and unused materials are cleaned and removed and stored appropriately
- 4.6. Workplace documentation is completed in accordance with workplace requirements
RANGE STATEMENT
The range statement relates to the unit of competency as a whole. It allows for different work environments and situations that may affect performance. Bold italicised wording, if used in the performance criteria, is detailed below. Essential operating conditions that may be present with training and assessment (depending on the work situation, needs of the candidate, accessibility of the item, and local industry and regional contexts) may also be included.
Unit context
Work requires individuals to demonstrate discretion, judgement and problem solving skills in the fabrication and installation process
Work is carried out in accordance with statutory requirements, environment legislation, manual handling procedures and relevant regulations, Australian standards, building codes and organisation insurance requirements
OHS requirements may include legislation, Australian standards, building codes, material safety management systems and local safe operating procedures
Work is generally performed individually, with general supervision and may be part of a production process
Residential windows may include:
aluminium sliding
double hung
casement and awning windows
louvre windows and double glazed windows
Residential doors may include:
aluminium sliding
hinged and bi-fold doors
Tools and equipment may include:
assembly benches
drop and up-cut saws
pneumatic
hydraulic and manual presses
frame and sash tooling
copy routers
end millers
crimpers
electric and pneumatic powered drills and screwdrivers
pop rivet guns
glue guns and general hand tools
Materials are to include but are not limited to:
aluminium alloys and steel
hardware
fasteners
plastics
sealants
tapes
vinyl
gaskets
timber reveals and flashings
Glass includes:
annealed glass
safety glass
patterned glass
tinted
heat reflective and insulated glass units
Hardware includes:
locks
wheels
stays
hinges
springs and balances and any component required for the operation of residential windows
Personal protective equipment
Personal protective equipment is to include that prescribed under legislation, regulations and enterprise practices and procedures. It may include:
gauntlets
gloves
safety glasses
hard hats
safety footwear
aprons and overalls
Information and procedures
Workplace procedures relating to the fabrication and installation of windows and doors
Equipment or tool manufacturer specifications and operational procedures
Work instructions, including job sheets, plans, drawings and designs
Safety standards include personal protective equipment, OHS regulations and enterprise requirements
Australian standards:
AS2047 Windows in buildings, selection and installation
AS1288 Glass in buildings, selection and installation
AS4667 Quality requirements for cut to size and processed glass
AS4666 Insulating glass units
WERS - The Window Energy Rating System
The range statement relates to the unit of competency as a whole. It allows for different work environments and situations that may affect performance. Bold italicised wording, if used in the performance criteria, is detailed below. Essential operating conditions that may be present with training and assessment (depending on the work situation, needs of the candidate, accessibility of the item, and local industry and regional contexts) may also be included.
Unit context
Work requires individuals to demonstrate discretion, judgement and problem solving skills in the fabrication and installation process
Work is carried out in accordance with statutory requirements, environment legislation, manual handling procedures and relevant regulations, Australian standards, building codes and organisation insurance requirements
OHS requirements may include legislation, Australian standards, building codes, material safety management systems and local safe operating procedures
Work is generally performed individually, with general supervision and may be part of a production process
Residential windows may include:
aluminium sliding
double hung
casement and awning windows
louvre windows and double glazed windows
Residential doors may include:
aluminium sliding
hinged and bi-fold doors
Tools and equipment may include:
assembly benches
drop and up-cut saws
pneumatic
hydraulic and manual presses
frame and sash tooling
copy routers
end millers
crimpers
electric and pneumatic powered drills and screwdrivers
pop rivet guns
glue guns and general hand tools
Materials are to include but are not limited to:
aluminium alloys and steel
hardware
fasteners
plastics
sealants
tapes
vinyl
gaskets
timber reveals and flashings
Glass includes:
annealed glass
safety glass
patterned glass
tinted
heat reflective and insulated glass units
Hardware includes:
locks
wheels
stays
hinges
springs and balances and any component required for the operation of residential windows
Personal protective equipment
Personal protective equipment is to include that prescribed under legislation, regulations and enterprise practices and procedures. It may include:
gauntlets
gloves
safety glasses
hard hats
safety footwear
aprons and overalls
Information and procedures
Workplace procedures relating to the fabrication and installation of windows and doors
Equipment or tool manufacturer specifications and operational procedures
Work instructions, including job sheets, plans, drawings and designs
Safety standards include personal protective equipment, OHS regulations and enterprise requirements
Australian standards:
AS2047 Windows in buildings, selection and installation
AS1288 Glass in buildings, selection and installation
AS4667 Quality requirements for cut to size and processed glass
AS4666 Insulating glass units
WERS - The Window Energy Rating System
EVIDENCE GUIDE
The Evidence Guide provides advice on assessment and must be read in conjunction with the performance criteria, required skills and knowledge, range statement and the Assessment Guidelines for the Training Package.
Critical aspects of evidence
Plan the fabrication and installation of windows and doors
Interpret work order/job instruction and locate and apply relevant information to fabricate and install windows and doors
Apply safe handling requirements for equipment, products and materials, including use of personal protective equipment
Follow work instructions, operating procedures and inspection practices to:
minimise the risk of injury to self and others
prevent damage to goods, equipment and products
maintain required production output and product quality
As a minimum, demonstrate the ability to:
measure for the installation of windows and doors
work from product specification data sheets and specifier software programs
identify and select product materials, including selection of mullions and transoms in relation to wind loading.
fabricate frame and sash components including cutting, tooling, routing, milling, drilling and crimping
identify, select and install component hardware, including weather seals, wheels, stays, hinges, guides and locks
apply the window energy rating system (WERS)
select and cut glass in accordance with AS1288 and AS4667
assemble frames, including glass, gaskets, tapes, sealants, adhesives, fasteners, reveal linings and flashings in accordance with AS2047, section 6
label and certify frames in accordance with AS2047, section 8
install residential windows and doors
calculate cost of residential windows and doors
Work effectively with others
Modify activities to cater for variations in workplace contexts and environment
Resource implications
Aluminium framing material, timber framing material, door or window glass, fittings, fixing/fasteners, workplace operating procedures, personal protective equipment and an appropriate work area.
Method of assessment
Assessment methods must confirm consistency of performance over time and in a range of workplace relevant contexts.
Assessment should be by direct observation of tasks and questioning on underpinning knowledge.
Assessment may be in conjunction with assessment of other relevant units of competency.
Context of assessment
Assessment may occur on the job or in a workplace simulated facility with relevant fabrication and installation equipment, materials, work instructions and deadlines.
The Evidence Guide provides advice on assessment and must be read in conjunction with the performance criteria, required skills and knowledge, range statement and the Assessment Guidelines for the Training Package.
Critical aspects of evidence
Plan the fabrication and installation of windows and doors
Interpret work order/job instruction and locate and apply relevant information to fabricate and install windows and doors
Apply safe handling requirements for equipment, products and materials, including use of personal protective equipment
Follow work instructions, operating procedures and inspection practices to:
minimise the risk of injury to self and others
prevent damage to goods, equipment and products
maintain required production output and product quality
As a minimum, demonstrate the ability to:
measure for the installation of windows and doors
work from product specification data sheets and specifier software programs
identify and select product materials, including selection of mullions and transoms in relation to wind loading.
fabricate frame and sash components including cutting, tooling, routing, milling, drilling and crimping
identify, select and install component hardware, including weather seals, wheels, stays, hinges, guides and locks
apply the window energy rating system (WERS)
select and cut glass in accordance with AS1288 and AS4667
assemble frames, including glass, gaskets, tapes, sealants, adhesives, fasteners, reveal linings and flashings in accordance with AS2047, section 6
label and certify frames in accordance with AS2047, section 8
install residential windows and doors
calculate cost of residential windows and doors
Work effectively with others
Modify activities to cater for variations in workplace contexts and environment
Resource implications
Aluminium framing material, timber framing material, door or window glass, fittings, fixing/fasteners, workplace operating procedures, personal protective equipment and an appropriate work area.
Method of assessment
Assessment methods must confirm consistency of performance over time and in a range of workplace relevant contexts.
Assessment should be by direct observation of tasks and questioning on underpinning knowledge.
Assessment may be in conjunction with assessment of other relevant units of competency.
Context of assessment
Assessment may occur on the job or in a workplace simulated facility with relevant fabrication and installation equipment, materials, work instructions and deadlines.
Replaces
| State Code | National Code | Title | Type |
|---|---|---|---|
| W0337 | LMFGG3016A | Fabricate and install residential windows and doors | Unit of competency |
Replaced By
| State Code | National Code | Title | Type |
|---|---|---|---|
| S7832 | LMFGG3016C | Fabricate and install residential windows and doors | Unit of competency |
| State Code | National Code | Title | Type |
|---|---|---|---|
| W034 | LMF30602 | Certificate III in Glass and Glazing | Qualification |
| 1478 | 52263 | Certificate II in Glass Glazing (Aluminium Windows and Frames) | Accredited course |