Whilst all efforts are made to provide accurate and timely information from the relevant source/documentation, please be aware that the information supplied may not be the most current version. The accuracy of the detail has not been confirmed by the Department and therefore should not be relied upon without first confirming the contents.
Provide engineering solutions for problems in complex multiple path circuits
Provide engineering solutions for problems in complex multiple path circuits
Unit of competency
National Code
UEECD0036
UEECD0036
State Code
OCA94
OCA94
TGA Status
Current
Current
DTWD Status
Approved
Approved
State Implementation and Classification
Approved Date
12/07/2021
Field of Education
031313 - Electrical Fitting, Electrical Mechanics
Original Release Date
12/07/2021
Nominal Hours
54
Description
This unit involves the skills and knowledge required to provide engineering solutions for problems in complex multiple path circuits.It includes preparing tools, equipment and materials; and providing solutions for complex multiple path circuits. It also includes completing work and documentation.No licensing, legislative or certification requirements apply to this unit at the time of publication.
Notes
Elements and Performance Criteria
1 Prepare tools, equipment and materials for problem solving
- 1.1 Work health and safety (WHS)/occupational health and safety (OHS) processes and workplace procedures for a given work area are identified, obtained and applied
- 1.2 WHS/OHS risk control work preparation measures and workplace procedures are followed
- 1.3 Scope of circuit/s problems are obtained from documentation and/or work instructions to determine the work
- 1.4 Advice is sought from the work supervisor to ensure the work is coordinated with others
- 1.5 Materials required for work are identified and accessed in accordance with workplace procedures
- 1.6 Tools, equipment and testing devices required for work are obtained and checked for correct operation and safety
2 Provide solutions for complex multiple path circuits
- 2.1 WHS/OHS risk control work measures and workplace procedures are followed
- 2.2 Inspect and test live work is conducted in accordance with WHS/OHS requirements and workplace procedures
- 2.3 Circuits are checked and isolated as required in accordance with WHS/OHS requirements and workplace procedures
- 2.4 Methods used to solve circuit problems are used from measured and calculated values as they apply to complex multiple path circuits
- 2.5 Unplanned situations are dealt with in accordance with WHS/OHS and approval of a relevant person
- 2.6 Problems are solved without damage to apparatus, circuits, the surrounding environment and/or services using sustainable energy practices
3 Complete work and documentation
- 3.1 WHS/OHS work completion risk control measures and workplace procedures are followed
- 3.2 Worksite is cleaned and made safe in accordance with workplace procedures
- 3.3 Justification for solutions used to solve circuit problems is documented
- 3.4 Work completion is documented and relevant person/s notified in accordance with workplace procedures
No information
No information
Replaces
| State Code | National Code | Title | Type |
|---|---|---|---|
| S7312 | UEENEEE125A | Provide engineering solutions for problems in complex multiple path circuits | Unit of competency |