Whilst all efforts are made to provide accurate and timely information from the relevant source/documentation, please be aware that the information supplied may not be the most current version. The accuracy of the detail has not been confirmed by the Department and therefore should not be relied upon without first confirming the contents.
Carry out operational checks on in-service electrical plant
Carry out operational checks on in-service electrical plant
Unit of competency
National Code
UEPOPS371
UEPOPS371
State Code
OAG65
OAG65
TGA Status
Replaced
Replaced
DTWD Status
Replaced
Replaced
State Implementation and Classification
Approved Date
15/05/2019
Field of Education
080399 - Business And Management, N.e.c.
Original Release Date
15/05/2019
Nominal Hours
36
Description
This unit involves the skills and knowledge required to conduct operational checks on in-service electrical plant. Operational maintenance checks need to be undertaken regularly to ensure the smooth and efficient operation of all in-service electrical plant in the power generation facility.Competency in this unit requires the ability to plan, carry out in-service electrical checks on electrical plant and completion of work. Individuals will, in general, work under supervision, in a power generation facility as an operator. Power generation plant operators are typically trained and authorised to isolate, prepare plant and issue permits to work.No licensing, legislative or certification requirements apply to this unit at the time of publication.Note: Workplace practiceThe application of the skills and knowledge described in this unit may require a licence or training permit to practice in the workplace where work is carried out on gas and electrical installations. Additional conditions may apply under state and territory legislative and regulatory licensing requirements.
Notes
Elements and Performance Criteria
1 Plan for electricalplant in-service checks
- 1.1 Safety issues are identified, in accordance with Work, Health and Safety (WHS)/Occupational Health and Safety (OHS) legislative requirements, industry standards and workplace procedures
- 1.2 Work, electrical plant and resource requirements are identified from relevant work orders and documentation, in accordance with workplace procedures
- 1.3 Electrical plant status and work requirements are confirmed with appropriate personnel or by site inspection, in accordance with workplace procedures
- 1.4 Equipment is checked for correct calibration and operation in accordance with workplace procedures
- 1.5 Correct size, type and quantity of materials and components are obtained and inspected for compliance with job specification, in accordance with workplace procedures
- 1.6 Potential hazards are identified and risk control measures are implemented in accordance with the workplace procedures,
- 1.7 Pre-access checks are carried out, in accordance with workplace procedures
2 Carry out in-service electrical checks
- 2.1 Electrical plant is operated, in accordance with workplace procedures and manufacturers' recommendations
- 2.2 Electrical plant checks are monitored, in accordance with workplace procedures, to detect deviations from normal operation
- 2.3 Electrical plant integrity and personnel safety are maintained, in accordance with workplace procedures, and through consultation with appropriate personnel and technical and operational documentation
3 Complete work
- 3.1 Electrical plant control measures are returned to required operational status on completion of checks, in accordance with workplace procedures
- 3.2 Appropriate personnel are notified of completion of work, in accordance with workplace procedures
- 3.3 Electrical plant problems or abnormalities are reported in accordance with workplace procedures
- 3.4 Operational check results are documented, in accordance with workplace procedures
No information
No information
Replaces
| State Code | National Code | Title | Type |
|---|---|---|---|
| WE386 | UEPOPS371A | Carry out operational checks on in-service electrical plant | Unit of competency |
Replaced By
| State Code | National Code | Title | Type |
|---|---|---|---|
| ODZ25 | UEPOPS004 | Carry out operational checks on in-service electrical plant | Unit of competency |
| State Code | National Code | Title | Type |
|---|---|---|---|
| BEB6 | UEP40218 | Certificate IV in ESI Generation - Operations | Qualification |
| BEC3 | UEP50218 | Diploma of ESI Generation - Operations | Qualification |
| BEB1 | UEP30218 | Certificate III in ESI Generation - Operations | Qualification |
| BEC2 | UEP30118 | Certificate III in ESI Generation - Systems Operations | Qualification |
| BEC0 | UEP40118 | Certificate IV in ESI Generation - Systems Operations | Qualification |
| BEB7 | UEP50118 | Diploma of ESI Generation - Systems Operations | Qualification |
| BEB0 | UEP50418 | Diploma of ESI Generation Maintenance - Electrical Electronic | Qualification |
| BEB4 | UEP40318 | Certificate IV in ESI Generation Maintenance - Electrical Electronics | Qualification |