Unit of competency Outline

Date retreived
23/07/2026 8:08 AM AWST

Whilst all efforts are made to provide accurate and timely information from the relevant source/documentation, please be aware that the information supplied may not be the most current version. The accuracy of the detail has not been confirmed by the Department and therefore should not be relied upon without first confirming the contents.

Operate a semi automatic defibrillator in an emergency

Operate a semi automatic defibrillator in an emergency

Unit of competency
National Code
PUAOPE010B
State Code
D3765
TGA Status
Replaced
DTWD Status
Replaced
Current Release Number
1.00
Current Release Date
09/02/2011
State Implementation and Classification
Approved Date
15/10/2010
Field of Education
069905 - Paramedical Studies
Original Release Date
15/10/2010
Nominal Hours
8
Description
Notes
Elements and Performance Criteria
No information
Casualties may include
Adults
Children over 8 years old/40kg

Hazards include
Contact with patient during defibrillation
Conductive surfaces (water, fluids, metal)
Explosive environments (oxygen, gases, fumes)
Unstable environment

Signs and symptoms may include
Casualty history
Details of incident
Medical history
Physical appearance
Vital signs

Equipment may include
Gauze wipes
Gloves
Razors
Resuscitation masks
SAED equipment used for delivery of external defibrillation
Shears
Spare battery

Pre-use check may include
Environmental factors that affect operation
Existence of suitable prominent warnings about precautions to be observed
For damage or malfunctions
To replenish and/or restore

Regulatory requirements may include
Australian Resuscitation Council requirements
Relevant State and Territory regulatory requirements

Reporting/recording faults and damage may include
Filling out and processing standard forms
Verbal communication

Critical aspects for assessment and evidence required to demonstrate competency in this unit
Assessment must confirm the ability to apply safe work practices while using the semi automatic defibrillator.
Assessment must also confirm that the individual has managed the situation in a calm and orderly manner and has taken every action to ensure the safety and comfort of the casualty.
Consistency in performance
Competency should be demonstrated over time across a range of emergency situations.

Context of and specific resources for assessment
Context of assessment
Competence should be assessed in a simulated emergency situation.
Simulation should recreate realistic emergency situations in which the individual is exposed to the full range of hazards and is placed under the same pressures and timelines associated with operating a semi automatic defibrillator in an emergency situation
Specific resources for assessment

Access to:

defibrillation equipment/kit
appropriate resuscitation manikin
suitable site or training area to simulate an emergency situation.

Guidance information for assessment
Information that will assist or guide assessment will be written during Phase II of the Review of the PUA00 Public Safety Training Package.

Replaced By
State Code National Code Title Type
D5499 PUAOPE010C Operate an automated external defibrillator in an emergency Unit of competency
No information