Whilst all efforts are made to provide accurate and timely information from the relevant source/documentation, please be aware that the information supplied may not be the most current version. The accuracy of the detail has not been confirmed by the Department and therefore should not be relied upon without first confirming the contents.

Install gas piping systems

Install gas piping systems

Unit of competency
National Code
CPCPGS3011A
State Code
W9696
TGA Status
Deleted
DTWD Status
Deleted
Current Release Number
1.00
Current Release Date
19/05/2011
State Implementation and Classification
Approved Date
04/09/2009
Field of Education
040327 - Plumbing
Original Release Date
04/09/2009
Nominal Hours
6
Description
This unit of competency specifies the outcomes required to select, install and test gas consumer piping carrying natural gas (NG), liquefied petroleum gas (LPG), or tempered liquefied petroleum gas (TLPG) up to 200kPa.
Notes
Elements and Performance Criteria
1. Identify gas piping system requirements.
  • 1.1. Building plans and specifications and any special instructions are obtained.
  • 1.2. Safety (OHS) requirements associated with the installation of gas piping systems, and workplace environmental requirements, are adhered to throughout the work.
  • 1.3. Quality assurance requirements for company operations are identified and adhered to.
  • 1.4. Gas load and design requirements are determined from design drawing or given information.
  • 1.5. Size of piping is calculated in accordance with relevant Australian standards, authorities' and workplace requirements.
  • 1.6. Set out of piping systems is in accordance with design drawing or instruction and complies with relevant Australian standards, authorities' and workplace requirements.
  • 1.7. Quantity and type of materials to conform to appropriate relevant Australian standards are estimated from design drawings or on-site dimensions.
2. Prepare for installation.
  • 2.1. Materials and equipment are ordered and checked for compliance with docket and order form, and for acceptable condition.
  • 2.2. Appropriate tools and equipment for piping system installation, including personal protective equipment, are identified, selected and checked for serviceability.
  • 2.3. Appropriate testing equipment is selected.
  • 2.4. Work is planned in conjunction with others involved in or affected by the work.
  • 2.5. Work area and materials are prepared to support efficient installation of the system.
3. Install and test piping system.
  • 3.1. Support system and installation method, including fixings, are selected to comply with manufacturer instructions, relevant Australian standards and workplace requirements.
  • 3.2. Pipe system is installed and jointed in accordance with design drawing or instruction and complies with relevant Australian standards and workplace requirements.
  • 3.3. System is tested in accordance with job requirements, relevant Australian standards and workplace requirements.
  • 3.4. Leaks are located and repaired and system is retested.
  • 3.5. Sustainability principles and concepts are applied throughout the installation.
  • 3.6. System is purged of air in accordance with relevant Australian standards.
  • 3.7. Test data is recorded in format required by regulating authority and workplace requirements.
4. Clean up.
  • 4.1. Work area is cleared and materials disposed of, reused or recycled in accordance with legislation, regulations, codes of practice and job specifications.
  • 4.2. Tools and equipment are cleaned, checked, maintained and stored in accordance with manufacturer recommendations and workplace procedures.
  • 4.3. Information is accessed and documentation completed in accordance with regulatory and workplace requirements.
RANGE STATEMENT
The range statement relates to the unit of competency as a whole. It allows for different work environments and situations that may affect performance. Bold italicised wording, if used in the performance criteria, is detailed below. Essential operating conditions that may be present with training and assessment (depending on the work situation, needs of the candidate, accessibility of the item, and local industry and regional contexts) may also be included.
Safety (OHS) is to be in accordance with commonwealth, state and territory legislation and regulations and may include:
handling of materials
hazard control
identification and testing for electrical hazards
personal protective clothing and equipment prescribed under legislation, regulations and workplace policies and practices
safe operating procedures, including recognising and preventing hazards associated with:
electricity
hazardous materials and substances
service lines
surrounding structures and facilities
trip hazards
use of installation tools and equipment
work site visitors and the public
working at heights
working in proximity to others
use of firefighting equipment
use of first aid equipment
workplace environment and safety.
Environmental requirements may include:
clean-up protection
waste management.
Quality assurance requirements may include:
Australian standards
Environment Protection Authority (EPA)
environment policy
internal company quality assurance policy and risk management strategy
International Standards Organisation
site safety plan
workplace operations and procedures.
Materials may include:
acceptable fittings and joints
copper
corrosion control materials
mechanical jointed steel
polyethylene (PE) and composite pipes
unplasticised polyvinyl chloride (PVC-U)
other approved materials.
Tools and equipment may include:
chain blocks
crimpers
flaring tools and silver brazing equipment
hacksaws
hand and power tools
hand trolleys
hoists and jacks
lifting and load shifting equipment and ladders
measuring equipment
oxy and arc welding equipment
pipe benders
rollers
spanners
test instruments
testing equipment
threading equipment
wrenches.
Sustainability principles and concepts:
Cover the current and future social, economic and environmental use of resources
may include:
appropriate component selection that has minimal environmental impact
choice of energy and water efficient appliances
efficient use and recycling of material
correct handling of hazardous materials
disposal of waste material to ensure minimal environmental impact.
Information may include:
charts and hand drawings
diagrams or sketches
instructions issued by authorised organisational or external personnel
job drawings
manufacturer specifications and instructions
material safety data sheets (MSDS)
memos
organisation work specifications and requirements
recognised formulas or tables accepted by the regulatory authority
regulatory and legislative requirements, particularly those pertaining to:
building codes
OHS and environmental requirements
plumbing and gasfitting authority regulations
relevant Australian standards
safe work procedures relating to installing and testing gas piping systems
signage
verbal, written and graphical instructions
work bulletins
work schedules, plans and specifications.
EVIDENCE GUIDE
The evidence guide provides advice on assessment and must be read in conjunction with the performance criteria, required skills and knowledge, range statement and the Assessment Guidelines for the Training Package.
Overview of assessment
This unit of competency could be assessed in the workplace or a close simulation of the workplace environment providing that simulated or project-based assessment techniques fully replicate plumbing and services workplace conditions, materials, activities, responsibilities and procedures.
Critical aspects for assessment and evidence required to demonstrate competency in this unit
A person who demonstrates competency in this unit must be able to provide evidence of:
locating, interpreting and applying relevant information, Australian standards and specifications to determine requirements, and installing and testing consumer gas piping systems
applying safety requirements throughout the work sequence, including electrical requirements and the use of personal protective clothing and equipment
as a minimum the ability to, given the plans and specifications, determine the requirements, install and test two gas piping systems, each comprising at least two materials and serving two Type A gas appliances; one being an NG pipeline from the outlet of a meter and the other being an LPG pipeline from a storage cylinder or tank, ensuring:
application of sustainability principles and concepts throughout
correct identification of design and details of proposed piping system
correct selection and use of appropriate processes, tools and equipment
completing all work to specification
compliance with regulations, relevant Australian standards and organisational quality procedures and processes
communicating and working effectively and safely with others.
Context of and specific resources for assessment
This competency is to be assessed using standard and authorised work practices, safety requirements and environmental constraints.
Assessment of essential underpinning knowledge will usually be conducted in an off-site context.
Assessment is to comply with relevant regulatory or Australian standards' requirements.
Resource implications for assessment include:
an induction procedure and requirement
realistic tasks or simulated tasks covering the minimum task requirements
relevant specifications and work instructions
tools and equipment appropriate to applying safe work practices
support materials appropriate to activity
workplace instructions relating to safe working practices and addressing hazards and emergencies
material safety data sheets
research resources, including industry related systems information.
Reasonable adjustments for people with disabilities must be made to assessment processes where required. This could include access to modified equipment and other physical resources, and the provision of appropriate assessment support.
Method of assessment
Assessment methods must:
satisfy the endorsed Assessment Guidelines of the Construction, Plumbing and Services Training Package
include direct observation of tasks in real or simulated work conditions, with questioning to confirm the ability to consistently identify and correctly interpret the essential underpinning knowledge required for practical application
reinforce the integration of employability skills with workplace tasks and job roles
confirm that competency is verified and able to be transferred to other circumstances and environments.
Validity and sufficiency of evidence requires that:
competency will need to be demonstrated over a period of time reflecting the scope of the role and the practical requirements of the workplace
where the assessment is part of a structured learning experience the evidence collected must relate to a number of performances assessed at different points in time and separated by further learning and practice, with a decision on competency only taken at the point when the assessor has complete confidence in the person's demonstrated ability and applied knowledge
all assessment that is part of a structured learning experience must include a combination of direct, indirect and supplementary evidence.
Assessment processes and techniques should as far as is practical take into account the language, literacy and numeracy capacity of the candidate in relation to the competency being assessed.
Supplementary evidence of competency may be obtained from relevant authenticated documentation from third parties, such as existing supervisors, team leaders or specialist training staff.
Replaces
State Code National Code Title Type
W2751 BCPGS3011A Purge consumer piping Unit of competency
Replaced By
State Code National Code Title Type
D7458 CPCPGS3021A Purge consumer piping Unit of competency
State Code National Code Title Type
W603 CPC32708 Certificate III in Gas Fitting Qualification
W600 CPC32408 Certificate III in Plumbing Qualification