Unit of competency Outline
Date retreived
22/07/2026 9:03 AM AWST
22/07/2026 9:03 AM AWST
Whilst all efforts are made to provide accurate and timely information from the relevant source/documentation, please be aware that the information supplied may not be the most current version. The accuracy of the detail has not been confirmed by the Department and therefore should not be relied upon without first confirming the contents.
Conduct field refuelling operations from a bulk fuel installation
Conduct field refuelling operations from a bulk fuel installation
Unit of competency
National Code
DEFPE001A
DEFPE001A
State Code
AVV56
AVV56
TGA Status
Replaced
Replaced
DTWD Status
Replaced
Replaced
State Implementation and Classification
Approved Date
Field of Education
030717 - Plant And Machine Operations
Original Release Date
Nominal Hours
0
Description
This unit covers the competency required to conduct refuelling of vehicles and plant from a bulk fuel installation in a field environment to transfer fuel products between storage mediums within the installation.
Notes
Elements and Performance Criteria
1. Prepare for refuelling operations
- 1.1 Refuelling tasks are received and confirmed with supervisor
- 1.2 Refuelling equipment is inspected and prepared for operation in accordance with workplace procedures
- 1.3 Personal protective equipment is selected and worn during refuelling operations
- 1.4 Fuel is tested for product contamination.
- 1.5 Contaminated product is quarantined and reported to supervisor
- 1.6 Work health and safety (WHS) requirements and recognised safety precautions are applied throughout the operation in accordance with standard procedures
- 1.7 Environmentally sustainable work practices are identified, assessed and implemented where feasible
2. Perform field refuelling and fuel transfer operations
- 2.1 Vehicles and plant are earthed to prevent discharge of static electricity prior to commencement of refuelling
- 2.2 Refuelling equipment is operated in accordance with manufacturers' instructions
- 2.3 Refuelling operations are conducted in accordance with workplace procedures
- 2.4 Fuel transfer process is monitored and faults are rectified or reported in accordance with workplace procedures
- 2.5 Emergencies/incidents are responded to in accordance with emergency response plans
- 2.6 Fuel transfer process is shut down in accordance with workplace procedures
- 2.7 Documentation is completed in accordance with workplace procedures
3. Cease refuelling operations
- 3.1 Bulk fuel installation is decommissioned in accordance with workplace procedures
- 3.2 Fuel transfer equipment is recovered in accordance with workplace procedures
- 3.3 Fuel transfer equipment is inspected and maintained in accordance with manufacturers' instructions
- 3.4 Maintenance documentation is completed in accordance with workplace procedures
- 3.5 Installation site is refurbished in accordance with organisational environmental policies and procedures
The Range Statement relates to the Unit of Competency as a whole. It allows for different work environments and situations that may affect performance. Bold italicised wording in the Performance Criteria is detailed below.
Refuelling equipment may include:
50 mm/100 mm fuel equipment including:
fittings
pipelines and hoses
pumps
valves, vessels and tanks
Measurement instruments including:
hydrometers
tapes
thermometers
Workplace procedures may include:
Australian Standards
Briefs
Duty statements
Legislative requirements
Manufacturers' handbooks, industry specifications and technical instructions
WHS regulations
Organisational policies and procedures
Procedure manuals
Relevant state/territory or federal legislation
Standard Operating Procedures
Technical procedures
Written or verbal instructions
Personal protective equipment may include:
Eye protection
Gloves
Hearing protection
High visibility clothing
Mask or respirator
Safety headwear and footwear
Testing fuel for product contamination must include:
Appearance
Particulate
Water
Emergencies/incidents may include:
Explosions
Fires
Fuel spills
Inhalation and/or skin contact with vapours and gases
Emergency response plans may include:
Fire plan
First aid plan
Spill/environmental plan
Decommissioning may include:
Deconstructing the system
Pigging the pipelines
Refuelling equipment may include:
50 mm/100 mm fuel equipment including:
fittings
pipelines and hoses
pumps
valves, vessels and tanks
Measurement instruments including:
hydrometers
tapes
thermometers
Workplace procedures may include:
Australian Standards
Briefs
Duty statements
Legislative requirements
Manufacturers' handbooks, industry specifications and technical instructions
WHS regulations
Organisational policies and procedures
Procedure manuals
Relevant state/territory or federal legislation
Standard Operating Procedures
Technical procedures
Written or verbal instructions
Personal protective equipment may include:
Eye protection
Gloves
Hearing protection
High visibility clothing
Mask or respirator
Safety headwear and footwear
Testing fuel for product contamination must include:
Appearance
Particulate
Water
Emergencies/incidents may include:
Explosions
Fires
Fuel spills
Inhalation and/or skin contact with vapours and gases
Emergency response plans may include:
Fire plan
First aid plan
Spill/environmental plan
Decommissioning may include:
Deconstructing the system
Pigging the pipelines
Critical aspects for assessment and evidence required to demonstrate competency in this unit
Assessment must confirm the ability to refuel vehicles and refuel plant.
Consistency in performance
Competency should be demonstrated over time to ensure the candidate is assessed across a wide variety of situations within the workplace.
Context of and specific resources for assessment
Context of assessment
Competency should be assessed in the workplace or a simulated environment.
Specific resources for assessment
Access is required to:
workplace refuelling equipment and fuel products
safety equipment and personal protective equipment
specific workplace operating procedures and publications
Assessment must confirm the ability to refuel vehicles and refuel plant.
Consistency in performance
Competency should be demonstrated over time to ensure the candidate is assessed across a wide variety of situations within the workplace.
Context of and specific resources for assessment
Context of assessment
Competency should be assessed in the workplace or a simulated environment.
Specific resources for assessment
Access is required to:
workplace refuelling equipment and fuel products
safety equipment and personal protective equipment
specific workplace operating procedures and publications
Replaced By
| State Code | National Code | Title | Type |
|---|---|---|---|
| BBB75 | DEFPET001 | Conduct field refuelling operations from a bulk fuel installation | Unit of competency |