Whilst all efforts are made to provide accurate and timely information from the relevant source/documentation, please be aware that the information supplied may not be the most current version. The accuracy of the detail has not been confirmed by the Department and therefore should not be relied upon without first confirming the contents.
Diagnose and rectify faults in electronic display circuits
Diagnose and rectify faults in electronic display circuits
Unit of competency
National Code
UEEEC0024
UEEEC0024
State Code
OBX41
OBX41
TGA Status
Current
Current
DTWD Status
Approved
Approved
State Implementation and Classification
Approved Date
12/07/2021
Field of Education
031317 - Electronic Equipment Servicing
Original Release Date
12/07/2021
Nominal Hours
54
Description
This unit involves the skills and knowledge required to diagnose and rectify faults in electronic display circuits.It includes fault finding and repair of faults in cathode ray tubes, liquid crystal and plasma display circuits. It also includes working safely, applying logical diagnostic methods and rectifying faults, safety and functional testing, and completing the necessary service documentation.Permits may be required for some work environments, such as confined spaces, working aloft, near live electrical apparatus and site rehabilitation.No licensing, legislative or certification requirements apply to this unit at the time of publication.
Notes
Elements and Performance Criteria
1 Prepare to diagnose and rectify electronic display circuit faults
- 1.1 Work health and safety (WHS)/occupational health and safety (OHS) requirements and workplace procedures for a given work area are identified and applied
- 1.2 WHS/OHS risk control measures and workplace procedures are followed in preparation for the work
- 1.3 Safety hazards which have not previously been identified are risk assessed, documented and risk control measures devised and implemented in consultation with appropriate person/s
- 1.4 Extent of faults is determined from reports, documentation and discussions with appropriate person/s
- 1.5 Appropriate person/s is consulted to ensure the work is coordinated effectively with others involved on the worksite
- 1.6 Tools, equipment and testing devices needed to diagnose faults are obtained in accordance with workplace procedures and checked for correct operation and safety
2 Diagnose and rectify electronic display circuit faults
- 2.1 WHS/OHS risk control measures and workplace procedures for carrying out electronic display circuit work are followed
- 2.2 Need to test and measure live work is determined in accordance with WHS/OHS requirements and, as required, conducted in accordance with workplace safety procedures
- 2.3 Circuits/machines/plant are checked and isolated in accordance with WHS/OHS requirements and workplace procedures
- 2.4 Logical diagnostic methods are applied to diagnose display circuits faults, employing measurements of circuit operating parameters referenced to display operating specifications
- 2.5 Suspected fault scenarios are tested as being the source of display circuit problems
- 2.6 Faults in the electronic components of the display circuits are rectified to display circuits operation and industry standards
- 2.7 Circuits are tested to verify that the display operates as intended in accordance with industry standards and to specified requirements
- 2.8 Unplanned situations are responded to in accordance with workplace procedures, discussions with appropriate person/s and consistent with job specifications and requirements in a manner that minimises risk to personnel and equipment
- 2.9 Diagnosis and rectification activities are carried out efficiently without waste of materials or damage to apparatus, the surrounding environment or services using sustainable energy practices
3 Complete and report fault diagnosis and rectification activities
- 3.1 WHS/OHS work completion risk control measures and workplace procedures are followed
- 3.2 Worksite is made safe in accordance with workplace safety procedures
- 3.3 Rectification of faults is documented in accordance with workplace procedures
- 3.4 Appropriate person/s is notified in accordance with workplace procedures that display circuit faults have been rectified
No information
No information
Replaces
| State Code | National Code | Title | Type |
|---|---|---|---|
| WC601 | UEENEEH176A | Diagnose and rectify faults in electronic display circuits | Unit of competency |
| State Code | National Code | Title | Type |
|---|---|---|---|
| BFP4 | UEE40720 | Certificate IV in Electronics and Communications | Qualification |
| BFQ2 | UEE60220 | Advanced Diploma of Electronics and Communications Engineering | Qualification |
| BFP5 | UEE50520 | Diploma of Electronics and Communications Engineering | Qualification |
| BFJ6 | UEE61720 | Advanced Diploma of Engineering Technology - Electronics | Qualification |
| BFO3 | UEE41720 | Certificate IV in Rail - Communications and Network Systems | Qualification |
| BFN7 | UEE41520 | Certificate IV in Video and Audio Systems | Qualification |