Unit of competency Outline
Date retreived
22/07/2026 10:29 AM AWST
22/07/2026 10:29 AM AWST
Whilst all efforts are made to provide accurate and timely information from the relevant source/documentation, please be aware that the information supplied may not be the most current version. The accuracy of the detail has not been confirmed by the Department and therefore should not be relied upon without first confirming the contents.
Install and adjust water service controls and devices
Install and adjust water service controls and devices
Unit of competency
National Code
CPCPWT3012A
CPCPWT3012A
State Code
D7500
D7500
TGA Status
Replaced
Replaced
DTWD Status
Replaced
Replaced
State Implementation and Classification
Approved Date
11/10/2011
Field of Education
040327 - Plumbing
Original Release Date
11/10/2011
Nominal Hours
12
Description
This unit of competency specifies the outcomes required to install water service controls and mixing devices used to manually control water mix and flow. It includes the basic adjustment and maintenance of correct flow operation for flushing devices, control valves, temperature control devices pumps and appliances, and excludes the commissioning and adjustment of backflow prevention devices and thermostatic mixing valves.
Notes
Elements and Performance Criteria
1. Prepare for work.
- 1.1. Drawings, plans and specifications are obtained.
- 1.2. Safety (OHS) requirements associated with installing and adjusting water service controls and devices, and workplace environmental requirements, are adhered to throughout the work.
- 1.3. Quality assurance requirements are identified and adhered to in accordance with workplace requirements.
- 1.4. Tasks are planned and sequenced in conjunction with others involved in or affected by the work and statutory and regulatory authority requirements.
- 1.5. Tools and equipment for installing and adjusting water service controls and mixing devices, including personal protective equipment, are selected and checked for serviceability.
- 1.6. Work area is prepared to support efficient installing and adjusting of water service controls and devices.
2. Identify installation requirements.
- 2.1. Service design requirements are identified from job specifications and in accordance with relevant Australian standards using relevant information.
- 2.2. Service controls and mixing devices are selected in accordance with relevant Australian standards, authorities' requirements and job specifications.
- 2.3. Available pressure and number of fixtures are determined from job specifications.
- 2.4. Valve size is selected in accordance with regulations, job specifications, manufacturer recommendations and design data.
- 2.5. Materials and equipment are identified, ordered and collected in accordance with workplace procedures.
- 2.6. Materials and equipment are checked for compliance with relevant Australian standards, docket and order form, and for acceptable condition.
- 2.7. Sustainability principles and concepts are applied to work preparation and application.
3. Install and adjust devices.
- 3.1. Devices and mixing valves are positioned and installed in accordance with relevant Australian standards, job specifications, manufacturer recommendations and authorities' requirements.
- 3.2. Pipework is flushed.
- 3.3. Devices are commissioned and maintained to ensure correct flow operation in accordance with relevant Australian standards, and manufacturer and job specifications.
- 3.4. Customer is advised of correct operation of flushing devices, control valves, appliances and pumps.
4. Clean up.
- 4.1. Work area is cleared and materials disposed of, reused or recycled according to legislation, regulations, codes of practice and job specification.
- 4.2. Tools and equipment are cleaned, checked, maintained and stored in accordance with manufacturer recommendations and workplace procedures.
- 4.3. Documentation is completed in accordance with workplace requirements.
RANGE STATEMENT
The range statement relates to the unit of competency as a whole. It allows for different work environments and situations that may affect performance. Bold italicised wording, if used in the performance criteria, is detailed below. Essential operating conditions that may be present with training and assessment (depending on the work situation, needs of the candidate, accessibility of the item, and local industry and regional contexts) may also be included.
Safety (OHS) is to be in accordance with commonwealth, state and territory legislation and regulations and may include:
handling of materials
hazard control
personal protective clothing and equipment prescribed under legislation, regulations and workplace policies and practices
safe operating procedures, including recognising and preventing hazards associated with:
electricity
hazardous materials and substances
other machines
surrounding structure and facilities
trip hazards
underground services
use of tools and equipment
work site visitors and the public
working at heights
working in confined spaces
working in proximity to others
use of firefighting equipment
use of first aid equipment
workplace environment and safety.
Environmental requirements cover water quality management and may include:
clean-up protection
stormwater protection
waste management.
Quality assurance requirements may include:
Environment Protection Authority (EPA)
environment policy
internal company quality assurance policy and risk management strategy
International Standards Organisation
site safety plan
workplace operations and procedures.
Statutory and regulatory authorities include:
commonwealth, state and local authorities administering applicable Acts, regulations and codes of practice.
Tools and equipment may include:
elevated work platforms
hand and power tools
ladders.
Water service controls and mixing devices:
include:
back flow prevention devices (install only)
isolating valves
line strainers
metal bodied taps
pressure limiting valves
temperature control devices
thermostatic mixing valves (install only)
types of appliances include:
automatic
domestic
industrial
manual
programmed.
Information may include:
charts and hand drawings
diagrams or sketches
instructions issued by authorised organisational or external personnel
job drawings
manufacturer specifications and instructions
material safety data sheets (MSDS)
memos
organisation work specifications and requirements
regulatory and legislative requirements, particularly those pertaining to:
building codes
OHS and environmental requirements
plumbing regulations
relevant Australian standards
safe work procedures relating to the installation and basic adjustment of water service controls and devices
signage
verbal, written and graphical instructions
work bulletins
work schedules, plans and specifications.
Materials may include:
water flushing devices
control valves
pumps
domestic and industrial appliances.
Sustainability principles and concepts:
cover the current and future social, economic and environmental use of resources
may include:
appropriate component selection that has minimal environmental impact
heat retention
efficient energy and water use
efficient use and recycling of material
disposal of waste material to ensure minimal environmental impact.
Flushing devices may include:
cisterns (manual, automatic and programmed on demand)
flushometers (flush valves).
Control valves may include:
automatic
flow control
isolation
manual
programmed
safety.
Pumps may include:
centrifugal and positive displacement.
The range statement relates to the unit of competency as a whole. It allows for different work environments and situations that may affect performance. Bold italicised wording, if used in the performance criteria, is detailed below. Essential operating conditions that may be present with training and assessment (depending on the work situation, needs of the candidate, accessibility of the item, and local industry and regional contexts) may also be included.
Safety (OHS) is to be in accordance with commonwealth, state and territory legislation and regulations and may include:
handling of materials
hazard control
personal protective clothing and equipment prescribed under legislation, regulations and workplace policies and practices
safe operating procedures, including recognising and preventing hazards associated with:
electricity
hazardous materials and substances
other machines
surrounding structure and facilities
trip hazards
underground services
use of tools and equipment
work site visitors and the public
working at heights
working in confined spaces
working in proximity to others
use of firefighting equipment
use of first aid equipment
workplace environment and safety.
Environmental requirements cover water quality management and may include:
clean-up protection
stormwater protection
waste management.
Quality assurance requirements may include:
Environment Protection Authority (EPA)
environment policy
internal company quality assurance policy and risk management strategy
International Standards Organisation
site safety plan
workplace operations and procedures.
Statutory and regulatory authorities include:
commonwealth, state and local authorities administering applicable Acts, regulations and codes of practice.
Tools and equipment may include:
elevated work platforms
hand and power tools
ladders.
Water service controls and mixing devices:
include:
back flow prevention devices (install only)
isolating valves
line strainers
metal bodied taps
pressure limiting valves
temperature control devices
thermostatic mixing valves (install only)
types of appliances include:
automatic
domestic
industrial
manual
programmed.
Information may include:
charts and hand drawings
diagrams or sketches
instructions issued by authorised organisational or external personnel
job drawings
manufacturer specifications and instructions
material safety data sheets (MSDS)
memos
organisation work specifications and requirements
regulatory and legislative requirements, particularly those pertaining to:
building codes
OHS and environmental requirements
plumbing regulations
relevant Australian standards
safe work procedures relating to the installation and basic adjustment of water service controls and devices
signage
verbal, written and graphical instructions
work bulletins
work schedules, plans and specifications.
Materials may include:
water flushing devices
control valves
pumps
domestic and industrial appliances.
Sustainability principles and concepts:
cover the current and future social, economic and environmental use of resources
may include:
appropriate component selection that has minimal environmental impact
heat retention
efficient energy and water use
efficient use and recycling of material
disposal of waste material to ensure minimal environmental impact.
Flushing devices may include:
cisterns (manual, automatic and programmed on demand)
flushometers (flush valves).
Control valves may include:
automatic
flow control
isolation
manual
programmed
safety.
Pumps may include:
centrifugal and positive displacement.
EVIDENCE GUIDE
The evidence guide provides advice on assessment and must be read in conjunction with the performance criteria, required skills and knowledge, range statement and the Assessment Guidelines for the Training Package.
Overview of assessment
This unit of competency could be assessed in the workplace or a close simulation of the workplace environment providing that simulated or project-based assessment techniques fully replicate plumbing and services workplace conditions, materials, activities, responsibilities and procedures.
Critical aspects for assessment and evidence required to demonstrate competency in this unit
A person who demonstrates competency in this unit must be able to provide evidence of:
locating, interpreting and applying relevant information, Australian standards and specifications to install and adjust water service controls and devices
applying safety requirements throughout the work sequence, including electrical requirements and the use of personal protective clothing and equipment
as a minimum the ability to, given the plans and specifications, install and provide basic adjustment for a cold water service incorporating both manual and programmed flushing devices and a heated/tempered water service consisting of mixing and tempering valves, ensuring:
correct identification of location, design and details of proposed installations
correct selection and use of appropriate processes, tools and equipment
completing all work to specification
compliance with regulations, relevant Australian standards and organisational quality procedures and processes
application of sustainability principles and concepts
communicating and working effectively and safely with others.
Context of and specific resources for assessment
This competency is to be assessed using standard and authorised work practices, safety requirements and environmental constraints.
Assessment of essential underpinning knowledge will usually be conducted in an off-site context.
Assessment is to comply with relevant regulatory or Australian standards' requirements.
Resource implications for assessment include:
an induction procedure and requirement
realistic tasks or simulated tasks covering the minimum task requirements
relevant specifications and work instructions
tools and equipment appropriate to applying safe work practices
support materials appropriate to activity
workplace instructions relating to safe working practices and addressing hazards and emergencies
material safety data sheets
research resources, including industry related systems information.
Reasonable adjustments for people with disabilities must be made to assessment processes where required. This could include access to modified equipment and other physical resources, and the provision of appropriate assessment support.
Method of assessment
Assessment methods must:
satisfy the endorsed Assessment Guidelines of the Construction, Plumbing and Services Training Package
include direct observation of tasks in real or simulated work conditions, with questioning to confirm the ability to consistently identify and correctly interpret the essential underpinning knowledge required for practical application
reinforce the integration of employability skills with workplace tasks and job roles
confirm that competency is verified and able to be transferred to other circumstances and environments.
Validity and sufficiency of evidence requires that:
competency will need to be demonstrated over a period of time reflecting the scope of the role and the practical requirements of the workplace
where the assessment is part of a structured learning experience the evidence collected must relate to a number of performances assessed at different points in time and separated by further learning and practice, with a decision on competency only taken at the point when the assessor has complete confidence in the person's demonstrated ability and applied knowledge
all assessment that is part of a structured learning experience must include a combination of direct, indirect and supplementary evidence.
Assessment processes and techniques should as far as is practical take into account the language, literacy and numeracy capacity of the candidate in relation to the competency being assessed.
Supplementary evidence of competency may be obtained from relevant authenticated documentation from third parties, such as existing supervisors, team leaders or specialist training staff.
The evidence guide provides advice on assessment and must be read in conjunction with the performance criteria, required skills and knowledge, range statement and the Assessment Guidelines for the Training Package.
Overview of assessment
This unit of competency could be assessed in the workplace or a close simulation of the workplace environment providing that simulated or project-based assessment techniques fully replicate plumbing and services workplace conditions, materials, activities, responsibilities and procedures.
Critical aspects for assessment and evidence required to demonstrate competency in this unit
A person who demonstrates competency in this unit must be able to provide evidence of:
locating, interpreting and applying relevant information, Australian standards and specifications to install and adjust water service controls and devices
applying safety requirements throughout the work sequence, including electrical requirements and the use of personal protective clothing and equipment
as a minimum the ability to, given the plans and specifications, install and provide basic adjustment for a cold water service incorporating both manual and programmed flushing devices and a heated/tempered water service consisting of mixing and tempering valves, ensuring:
correct identification of location, design and details of proposed installations
correct selection and use of appropriate processes, tools and equipment
completing all work to specification
compliance with regulations, relevant Australian standards and organisational quality procedures and processes
application of sustainability principles and concepts
communicating and working effectively and safely with others.
Context of and specific resources for assessment
This competency is to be assessed using standard and authorised work practices, safety requirements and environmental constraints.
Assessment of essential underpinning knowledge will usually be conducted in an off-site context.
Assessment is to comply with relevant regulatory or Australian standards' requirements.
Resource implications for assessment include:
an induction procedure and requirement
realistic tasks or simulated tasks covering the minimum task requirements
relevant specifications and work instructions
tools and equipment appropriate to applying safe work practices
support materials appropriate to activity
workplace instructions relating to safe working practices and addressing hazards and emergencies
material safety data sheets
research resources, including industry related systems information.
Reasonable adjustments for people with disabilities must be made to assessment processes where required. This could include access to modified equipment and other physical resources, and the provision of appropriate assessment support.
Method of assessment
Assessment methods must:
satisfy the endorsed Assessment Guidelines of the Construction, Plumbing and Services Training Package
include direct observation of tasks in real or simulated work conditions, with questioning to confirm the ability to consistently identify and correctly interpret the essential underpinning knowledge required for practical application
reinforce the integration of employability skills with workplace tasks and job roles
confirm that competency is verified and able to be transferred to other circumstances and environments.
Validity and sufficiency of evidence requires that:
competency will need to be demonstrated over a period of time reflecting the scope of the role and the practical requirements of the workplace
where the assessment is part of a structured learning experience the evidence collected must relate to a number of performances assessed at different points in time and separated by further learning and practice, with a decision on competency only taken at the point when the assessor has complete confidence in the person's demonstrated ability and applied knowledge
all assessment that is part of a structured learning experience must include a combination of direct, indirect and supplementary evidence.
Assessment processes and techniques should as far as is practical take into account the language, literacy and numeracy capacity of the candidate in relation to the competency being assessed.
Supplementary evidence of competency may be obtained from relevant authenticated documentation from third parties, such as existing supervisors, team leaders or specialist training staff.
Replaces
| State Code | National Code | Title | Type |
|---|---|---|---|
| W9759 | CPCPWT3002A | Install and adjust water service controls and devices | Unit of competency |
Replaced By
| State Code | National Code | Title | Type |
|---|---|---|---|
| WF966 | CPCPWT3022A | Install and adjust water service controls and devices | Unit of competency |
| State Code | National Code | Title | Type |
|---|---|---|---|
| D411 | CPC32411 | Certificate III in Plumbing | Qualification |