Unit of competency Outline

Date retreived
22/07/2026 8:37 AM AWST

Whilst all efforts are made to provide accurate and timely information from the relevant source/documentation, please be aware that the information supplied may not be the most current version. The accuracy of the detail has not been confirmed by the Department and therefore should not be relied upon without first confirming the contents.

Collect and store roof water

Collect and store roof water

Unit of competency
National Code
CPCPRF2023A
State Code
WF948
TGA Status
Replaced
DTWD Status
Replaced
Current Release Number
1.00
Current Release Date
07/02/2013
State Implementation and Classification
Approved Date
20/06/2014
Field of Education
040327 - Plumbing
Original Release Date
20/06/2014
Nominal Hours
24
Description
This unit of competency specifies the outcomes required to determine storage requirements and to plan, prepare and install storage tanks and related piping for the collection and storage of roof water.The unit requires the installation of water storage tanks of at least 1000 litres capacity.
Notes
Elements and Performance Criteria
1 Identify water storage system requirements.
  • 1.1 Plans, specifications and any special instructions are obtained.
  • 1.2 Work health and safety (WHS) and environmental requirements associated with collecting and storing roof water are adhered to throughout the work.
  • 1.3 Quality assurance requirements for company operations are identified and adhered to.
  • 1.4 Site's annual rainfall is determined from meteorological or other relevant data.
  • 1.5 Roof catchment area is determined from plans or site inspection.
  • 1.6 Water consumption requirements for the installation are determined.
  • 1.7 Total water storage requirements for the installation are determined.
  • 1.8 Criteria for storage tanks, gutters, downpipes and other system components are determined according to relevant Australian standard and other information.
2 Plan and prepare for installation.
  • 2.1 Required materials are identified, ordered and collected according to workplace procedures.
  • 2.2 Work is planned in conjunction with others involved in or affected by the work.
  • 2.3 Materialsare checked for compliance with docket and order form and for acceptable condition, and faults are reported.
  • 2.4 Work area and materials are prepared to support efficient installation.
  • 2.5 Sustainability principles and concepts are observed when preparing for and undertaking work process.
3 Install storage system.
  • 3.1 Set out complies with design drawings or instructions.
  • 3.2 Preparatory work, including installation of tank stand or standing, is carried out to specification without damage to surrounding structures or existing services.
  • 3.3 System is installed according to job specification and statutory and regulatory authorities’ requirements.
4 Clean up.
  • 4.1 Work area is cleared and materials disposed of, reused or recycled according to legislation, regulations, codes of practice and job specification.
  • 4.2 Tools and equipmentare cleaned, checked, maintained and stored according to manufacturer recommendations and workplace procedures.
  • 4.3 Documentation is completed according to workplace requirements.
The range statement relates to the unit of competency as a whole. It allows for different work environments and situations that may affect performance. Bold italicised wording, if used in the performance criteria, is detailed below. Essential operating conditions that may be present with training and assessment (depending on the work situation, needs of the candidate, accessibility of the item, and local industry and regional contexts) may also be included.
Work health and safety is to be according to commonwealth, state and territory legislation and regulations and may include:
handling of materials
hazard control
personal protective clothing and equipment prescribed under legislation, regulations and workplace policies and practices
safe operating procedures, including recognising and preventing hazards associated with:
electricity
hazardous materials and substances
service lines
surrounding structures and facilities
trip hazards
use of tools and equipment
work site visitors and the public
working at heights
working in proximity to others
use of firefighting equipment
use of first aid equipment
workplace environment and safety.

Environmental requirements cover water quality management and may include:
clean-up protection
stormwater protection
waste management.

Roof water collected and stored may be for:
drinking or non-drinking purposes.

Quality assurance requirements may include:
environment policy
Environment Protection Authority (EPA)
internal company quality assurance policy and risk management strategy
International Standards Organisation
site safety plan
workplace operations and procedures.

Storage tanks may be of:
any authorised material.

Information may include:
charts and hand drawings
instructions issued by authorised organisational or external personnel
manufacturer specifications and instructions
material safety data sheets (MSDS)
memos
organisation work specifications and requirements
plans and sketches
regulatory and legislative requirements, particularly those pertaining to:
building codes
WHS and environmental requirements
plumbing regulations
relevant Australian standards
safe work procedures relating to determining, preparing and installing collection and storage systems for roof water
signage
verbal, written and graphical instructions
work bulletins
work schedules, plans and specifications.

Materials for installing storage tanks are to include:
water storage tanks, and components of authorised materials that comply with local authorities’ requirements, such as:
coated steel materials
metal guttering
PVC
sealants
tank stand.

Fault reporting:
may be written or verbal
is to be according to company's workplace procedures.

Sustainability principles and concepts:
cover the current and future social, economic and environmental use of resources
may include:
efficient energy use
rainwater harvesting
efficient use and recycling of material
disposing of waste material to ensure minimal environmental impact
selecting appropriate components to ensure minimal environmental impact.

Installation covers:
both gravity and pump retrieval systems.

Statutory and regulatory authorities include:
commonwealth, state or territory, and local authorities administering applicable Acts, regulations and codes of practice.

Tools and equipment may include:
hand and power tools
ladders
levelling equipment
lifting and load shifting equipment, including:
chain blocks
excavation equipment
forklifts
hand trolleys
hoists and jacks
rollers
measuring equipment.
The evidence guide provides advice on assessment and must be read in conjunction with the performance criteria, required skills and knowledge, range statement and the Assessment Guidelines for the Training Package.
Overview of assessment
This unit of competency could be assessed in the workplace or a close simulation of the workplace environment providing that simulated or project-based assessment techniques fully replicate plumbing and services workplace conditions, materials, activities, responsibilities and procedures.

Critical aspects for assessment and evidence required to demonstrate competency in this unit
A person who demonstrates competency in this unit must be able to provide evidence of:
locating, interpreting and applying relevant information, relevant Australian standards and specifications for determining requirements, planning and installing storage tanks for drinking water
applying safety requirements throughout the work sequence, including electrical safety requirements and the use of personal protective clothing and equipment
given the plans and specifications, completing the following in respect of roof water collection and storage systems:
calculate the water catchment area of a roof, the gutter and downpipe materials required and the amount of water storage required for a given job
determine system requirements from plans and specifications according to local authorities’ requirements
planning the layout and installation of a storage tank of not less than 1000 litres capacity, incorporating an inlet connection and a first flush device from a roof catchment area, and an overflow to be connected to an approved stormwater point of discharge, ensuring:
application of sustainability principles and concepts
correct identification of location, design and details of proposed storage
correct selection and use of appropriate processes, tools and equipment
completing all work to specification
compliance with regulations, relevant Australian standards and organisational quality procedures and processes
communicating and working effectively and safely with others.

Context of and specific resources for assessment
This competency is to be assessed using standard and authorised work practices, safety requirements and environmental constraints.
Assessment of essential underpinning knowledge will usually be conducted in an off-site context.
Assessment is to comply with relevant regulatory or Australian standards’ requirements.
Resource implications for assessment include:
an induction procedure and requirement
realistic tasks or simulated tasks covering the minimum task requirements
relevant specifications and work instructions
tools and equipment appropriate to applying safe work practices
support materials appropriate to activity
workplace instructions relating to safe working practices and addressing hazards and emergencies
material safety data sheets
research resources, including industry-related systems information.
Reasonable adjustments for people with disabilities must be made to assessment processes where required. This could include access to modified equipment and other physical resources, and the provision of appropriate assessment support.

Method of assessment
Assessment methods must:
satisfy the endorsed Assessment Guidelines of the Construction, Plumbing and Services Training Package
include direct observation of tasks in real or simulated work conditions, with questioning to confirm the ability to consistently identify and correctly interpret the essential underpinning knowledge required for practical application
reinforce the integration of employability skills with workplace tasks and job roles
confirm that competency is verified and able to be transferred to other circumstances and environments.
Validity and sufficiency of evidence requires that:
competency will need to be demonstrated over a period of time reflecting the scope of the role and the practical requirements of the workplace
where the assessment is part of a structured learning experience the evidence collected must relate to a number of performances assessed at different points in time and separated by further learning and practice, with a decision on competency only taken at the point when the assessor has complete confidence in the person's demonstrated ability and applied knowledge
all assessment that is part of a structured learning experience must include a combination of direct, indirect and supplementary evidence.
Assessment processes and techniques should as far as is practical take into account the language, literacy and numeracy capacity of the candidate in relation to the competency being assessed.
Supplementary evidence of competency may be obtained from relevant authenticated documentation from third parties, such as existing supervisors, team leaders or specialist training staff.
Replaces
State Code National Code Title Type
D7482 CPCPRF2013A Collect and store roof water Unit of competency
Replaced By
State Code National Code Title Type
OCN06 CPCPRF2023 Collect and store roof water Unit of competency