Whilst all efforts are made to provide accurate and timely information from the relevant source/documentation, please be aware that the information supplied may not be the most current version. The accuracy of the detail has not been confirmed by the Department and therefore should not be relied upon without first confirming the contents.
Install ancillary electronic control unit systems and components
Install ancillary electronic control unit systems and components
Unit of competency
National Code
AURETR3027
AURETR3027
State Code
WF109
WF109
TGA Status
Replaced
Replaced
DTWD Status
Replaced
Replaced
State Implementation and Classification
Approved Date
16/07/2013
Field of Education
030505 - Automotive Electrics And Electronics
Original Release Date
16/07/2013
Nominal Hours
35
Description
This unit describes the performance outcomes required to install ancillary electrical equipment systems and components in electronic control units (ECUs).The unit may require service programming code to connect and interface components to the vehicle computer area network databus (CAN-bus) network.The unit includes identifying and confirming work requirements, preparing for work, and completing work finalisation processes, including clean-up and documentation.Licensing, legislative, regulatory or certification requirements may apply to this unit in some jurisdictions. Users are advised to check with the relevant regulatory authority.
Notes
Elements and Performance Criteria
1. Prepare for work
- 1.1. Workplace instructions are used to determine job requirements
- 1.2. Workplace health and safety (WHS) requirements are observed throughout the work
- 1.3. Procedures and information are sourced and interpreted
- 1.4. Installation options are analysed and those most appropriate to the circumstances are selected and prepared
- 1.5. Tools and equipment are identified for effective installation and testing procedures
2. Install and program ancillary electronic components
- 2.1. Basic ancillary electrical equipment is installed according to manufacturer and component supplier specifications
- 2.2. Programming code is sought from original equipment manufacturer (OEM) to enable installed equipment to communicate with vehicle electrical system
- 2.3. Testing is carried out using tools and diagnostic techniques without causing damage to components or systems as a result of inappropriate testing procedures
- 2.4. Faults are identified and preferred repair action is determined and carried out
- 2.5. Post-repair testing is carried out according to workplace procedures and relevant legislation
3. Prepare vehicle and equipment for delivery to customer
- 3.1. Final inspection is made to ensure work is to workplace expectations
- 3.2. Vehicle is cleaned to workplace expectations and presented ready for use
- 3.3. Workplace documentation is processed according to workplace procedures
4. Clean up work area and maintain equipment
- 4.1. Material that can be reused is collected and stored
- 4.2. Waste and scrap are removed following workplace procedures
- 4.3. Equipment and work area are cleaned and inspected for serviceable condition according to workplace procedures
- 4.4. Faulty equipment is identified, tagged and isolated according to workplace procedures
- 4.5. Operator maintenance is completed according to manufacturer and component supplier specifications and site procedures
- 4.6. Tools and equipment are maintained according to workplace procedures
RANGE STATEMENT
The range statement relates to the unit of competency as a whole. It allows for different work environments and situations that may affect performance. Bold italicised wording, in the performance criteria, is detailed below. Essential operating conditions that may be present with training and assessment (depending on the work situation, needs of the candidate, accessibility of the item, and local industry and regional contexts) may also be included.
Workplace instructions may include:
electronic or hard copy instructions
verbal instructions
written instructions.
Job requirements may include:
diagnosis and repair methods, processes and equipment.
Workplace health and safety requirements may include:
personal protective clothing and equipment
hazards associated with high voltage ignition systems
safe use of tools and equipment
safe handling of material
use of fire-fighting equipment
workplace safety policies and procedures
workplace first aid equipment
hazard control, including control of hazardous materials and toxic substances.
Procedures and information may include:
verbal, written and graphical instructions
signage
work schedules, plans and specifications
work bulletins and memos
material safety data sheets (MSDS)
diagrams and sketches
regulatory and legislative requirements relating to automotive industry
Australian Design Rules
engineer's design specifications and instructions
workplace work specifications and requirements
instructions issued by authorised workplace or external persons
Australian standards
vehicle service requirements and repair manuals.
Installation options may include:
OEM and workplace instructions
equipment manufacturer and supplier instructions
aftermarket accessory instructions
SPS procedures and OEM intellectual property (IP) code
visual inspection and evaluation of components.
Tools and equipment may include:
hand tools
testing equipment, including multimeters and ohmmeters
insulation testers
crimping tools
soldering iron
heat-gun or blower
wire and cabling of various colours and sizes
heat shrink sleeving and flexible conduit
terminals and connectors
electrical tape.
Electronic ancillary electrical equipment may include:
driver ignition immobiliser interlocks
security alarm and immobiliser systems
infotainment - audio systems
vehicle engine and powertrain performance enhancements
mobile phone interface kits
speed alert and traffic warning systems
integrated navigation systems.
Programming code may include:
service programming system
OEM-specific code
ECU flash code or program.
Inappropriate testing proceduresmay include:
intrusive testing (which must not be performed as it is not a recommended test and repair method), which includes:
back probing terminals and connectors and fuse holders with inappropriate test probes
probing terminal and connectors with inappropriate test probes
pushing sharp probes and objects into wiring insulation.
Faults may include:
open circuits
short circuits
damaged insulation
frayed wires
connector damage
terminal damage
diagnosis trouble codes (DTC) being set.
Repair options may include:
pre- and post-repair testing
identifying and testing components
diagnosing and determining faults
component repair procedures, including:
removal, replacement and adjustment procedures
dismantle, repair, re-assembly and adjustment procedures
electrical measurements
visual and functional assessments, including for damage and wear.
Post-repair testing may include:
validating effectiveness of the repair action
confirming that reported fault has been rectified
confirming that no other faults are present as a result of the repair action.
The range statement relates to the unit of competency as a whole. It allows for different work environments and situations that may affect performance. Bold italicised wording, in the performance criteria, is detailed below. Essential operating conditions that may be present with training and assessment (depending on the work situation, needs of the candidate, accessibility of the item, and local industry and regional contexts) may also be included.
Workplace instructions may include:
electronic or hard copy instructions
verbal instructions
written instructions.
Job requirements may include:
diagnosis and repair methods, processes and equipment.
Workplace health and safety requirements may include:
personal protective clothing and equipment
hazards associated with high voltage ignition systems
safe use of tools and equipment
safe handling of material
use of fire-fighting equipment
workplace safety policies and procedures
workplace first aid equipment
hazard control, including control of hazardous materials and toxic substances.
Procedures and information may include:
verbal, written and graphical instructions
signage
work schedules, plans and specifications
work bulletins and memos
material safety data sheets (MSDS)
diagrams and sketches
regulatory and legislative requirements relating to automotive industry
Australian Design Rules
engineer's design specifications and instructions
workplace work specifications and requirements
instructions issued by authorised workplace or external persons
Australian standards
vehicle service requirements and repair manuals.
Installation options may include:
OEM and workplace instructions
equipment manufacturer and supplier instructions
aftermarket accessory instructions
SPS procedures and OEM intellectual property (IP) code
visual inspection and evaluation of components.
Tools and equipment may include:
hand tools
testing equipment, including multimeters and ohmmeters
insulation testers
crimping tools
soldering iron
heat-gun or blower
wire and cabling of various colours and sizes
heat shrink sleeving and flexible conduit
terminals and connectors
electrical tape.
Electronic ancillary electrical equipment may include:
driver ignition immobiliser interlocks
security alarm and immobiliser systems
infotainment - audio systems
vehicle engine and powertrain performance enhancements
mobile phone interface kits
speed alert and traffic warning systems
integrated navigation systems.
Programming code may include:
service programming system
OEM-specific code
ECU flash code or program.
Inappropriate testing proceduresmay include:
intrusive testing (which must not be performed as it is not a recommended test and repair method), which includes:
back probing terminals and connectors and fuse holders with inappropriate test probes
probing terminal and connectors with inappropriate test probes
pushing sharp probes and objects into wiring insulation.
Faults may include:
open circuits
short circuits
damaged insulation
frayed wires
connector damage
terminal damage
diagnosis trouble codes (DTC) being set.
Repair options may include:
pre- and post-repair testing
identifying and testing components
diagnosing and determining faults
component repair procedures, including:
removal, replacement and adjustment procedures
dismantle, repair, re-assembly and adjustment procedures
electrical measurements
visual and functional assessments, including for damage and wear.
Post-repair testing may include:
validating effectiveness of the repair action
confirming that reported fault has been rectified
confirming that no other faults are present as a result of the repair action.
EVIDENCE GUIDE
The evidence guide provides advice on assessment and must be read in conjunction with the Performance Criteria, required Skills and Knowledge, the Range Statement and the Assessment Guidelines for the Training Package.
Overview of assessment
Critical aspects for assessment and evidence required to demonstrate competency in this unit
The evidence required to demonstrate competency in this unit must be relevant to workplace operations and satisfy all of the requirements of the performance criteria and required skills and knowledge.
A person who demonstrates competency in this unit must be able to:
observe safety procedures and requirements
select methods and techniques appropriate to the circumstances
complete preparatory activity in a systematic manner
read and interpret vehicle wiring diagrams
install electronic ancillary electrical components to specification
apply programming code processes to enable communication between ancillary component and vehicle system
test electrical wiring harness and looms to locate possible faults
conduct installation according to workplace, manufacturer and component supplier requirements
accurately interpret test results
present vehicle and equipment in a condition that complies with workplace requirements.
Context of, and specific resources for assessment
Competency is to be assessed in the workplace or a simulated workplace environment that accurately reflects performance in a real workplace setting.
Assessment is to occur:
using standard workplace practices and procedures
following safety requirements
applying environmental constraints.
Assessment is to comply with relevant:
regulatory requirements
Australian standards
industry codes of practice.
The following resources must be made available for the assessment of this unit:
workplace location or simulated workplace
materials relevant to the installation of electronic ancillary electrical components that could be fitted to a range of vehicles relevant to the qualification being sought
equipment, and hand and power tools appropriate to installing basic ancillary electrical components
specifications and work instructions.
Method of assessment
Assessment must satisfy the endorsed Assessment Guidelines of this Training Package.
Assessment methods must confirm consistency and accuracy of performance (over time and in a range of workplace relevant contexts) together with the application of required skills and knowledge.
Assessment methods must be by direct observation of tasks and include questioning on required skills and knowledge to ensure correct interpretation and application.
Competence in this unit may be assessed in conjunction with other units which together form part of a holistic work role.
Where applicable, reasonable adjustment must be made to work environments and training situations to accommodate the needs of diverse clients.
Assessment processes and techniques must be culturally sensitive and appropriate to the language, literacy and numeracy capacity of the candidate and the work being performed.
The evidence guide provides advice on assessment and must be read in conjunction with the Performance Criteria, required Skills and Knowledge, the Range Statement and the Assessment Guidelines for the Training Package.
Overview of assessment
Critical aspects for assessment and evidence required to demonstrate competency in this unit
The evidence required to demonstrate competency in this unit must be relevant to workplace operations and satisfy all of the requirements of the performance criteria and required skills and knowledge.
A person who demonstrates competency in this unit must be able to:
observe safety procedures and requirements
select methods and techniques appropriate to the circumstances
complete preparatory activity in a systematic manner
read and interpret vehicle wiring diagrams
install electronic ancillary electrical components to specification
apply programming code processes to enable communication between ancillary component and vehicle system
test electrical wiring harness and looms to locate possible faults
conduct installation according to workplace, manufacturer and component supplier requirements
accurately interpret test results
present vehicle and equipment in a condition that complies with workplace requirements.
Context of, and specific resources for assessment
Competency is to be assessed in the workplace or a simulated workplace environment that accurately reflects performance in a real workplace setting.
Assessment is to occur:
using standard workplace practices and procedures
following safety requirements
applying environmental constraints.
Assessment is to comply with relevant:
regulatory requirements
Australian standards
industry codes of practice.
The following resources must be made available for the assessment of this unit:
workplace location or simulated workplace
materials relevant to the installation of electronic ancillary electrical components that could be fitted to a range of vehicles relevant to the qualification being sought
equipment, and hand and power tools appropriate to installing basic ancillary electrical components
specifications and work instructions.
Method of assessment
Assessment must satisfy the endorsed Assessment Guidelines of this Training Package.
Assessment methods must confirm consistency and accuracy of performance (over time and in a range of workplace relevant contexts) together with the application of required skills and knowledge.
Assessment methods must be by direct observation of tasks and include questioning on required skills and knowledge to ensure correct interpretation and application.
Competence in this unit may be assessed in conjunction with other units which together form part of a holistic work role.
Where applicable, reasonable adjustment must be made to work environments and training situations to accommodate the needs of diverse clients.
Assessment processes and techniques must be culturally sensitive and appropriate to the language, literacy and numeracy capacity of the candidate and the work being performed.
Replaced By
| State Code | National Code | Title | Type |
|---|---|---|---|
| AXD76 | AURETR027 | Install ancillary electronic systems and components | Unit of competency |
| State Code | National Code | Title | Type |
|---|---|---|---|
| J391 | AUR30312 | Certificate III in Automotive Electrical Technology | Qualification |