Whilst all efforts are made to provide accurate and timely information from the relevant source/documentation, please be aware that the information supplied may not be the most current version. The accuracy of the detail has not been confirmed by the Department and therefore should not be relied upon without first confirming the contents.
Install LPG storage of aggregate storage capacity up to 500 litres
Install LPG storage of aggregate storage capacity up to 500 litres
Unit of competency
National Code
CPCPGS3014A
CPCPGS3014A
State Code
W9699
W9699
TGA Status
Deleted
Deleted
DTWD Status
Deleted
Deleted
State Implementation and Classification
Approved Date
04/09/2009
Field of Education
040327 - Plumbing
Original Release Date
04/09/2009
Nominal Hours
10
Description
This unit of competency specifies the outcomes required to install liquefied petroleum gas (LPG) storage facilities with a storage capacity up to 500 litres for consumer piping systems.The unit requires the selection, location and installation of LPG storage facilities with a storage capacity of up to 500 litres, either single tank or multiple cylinder installations and the testing of the associated piping system. The storage is connected to consumer piping systems with operating pressures less than 200kPa. The design requirements of this unit are limited to the application of the design to layout and installation.
Notes
Elements and Performance Criteria
1. Identify LPG storage requirements.
- 1.1. Design, drawings, specifications and any special instructions are obtained.
- 1.2. Safety (OHS) requirements associated with the installation of LPG storage facilities, and workplace environmental requirements, are adhered to throughout the work.
- 1.3. Quality assurance requirements for company operations are identified and adhered to.
- 1.4. Gas load and design requirements are determined from plans, specifications, and job drawing or workplace instructions.
- 1.5. Storage capacity is calculated in compliance with regulatory authority and workplace requirements.
- 1.6. Type of storage is determined in accordance with job and workplace requirements.
- 1.7. Containers and type of system (one or two stage) are selected in accordance with standards, job and workplace requirements.
- 1.8. Appropriate regulators are determined to meet capacity and load of the system in accordance with workplace requirements.
- 1.9. Appropriateness of selected location to provide the required service is established in conformance to standards and workplace requirements.
- 1.10. Quantity of materials required is calculated from design, drawings and specifications in conformance to workplace requirements.
2. Prepare for installation.
- 2.1. Materials and equipment are ordered and checked for compliance with docket and order form, and for acceptable condition.
- 2.2. Appropriate tools and equipment for storage facility installation, including personal protective equipment, are identified, selected and checked for serviceability.
- 2.3. Appropriate testing apparatus is selected.
- 2.4. Work is planned in conjunction with others involved in or affected by the work.
- 2.5. Work area and materials are prepared to support efficient installation of the system.
3. Install and test LPG storage system.
- 3.1. Container supports and base, piping, fittings and components are selected in conformance to standards and workplace requirements.
- 3.2. Size and method of connection are selected in conformance to standards and workplace requirements.
- 3.3. Tank is purged in accordance with standards.
- 3.4. System from cylinder outlet is tested, purged and regulator adjusted to be gas-tight, in conformance to regulatory authority and workplace requirements.
- 3.5. Test data is recorded in format required by regulatory authority and workplace requirements.
4. Clean up.
- 4.1. Work area is cleared and materials disposed of or recycled in accordance with state or territory statutory and regulatory authority legislation and workplace procedures.
- 4.2. Tools and equipment are cleaned, checked, maintained and stored in accordance with manufacturer recommendations and workplace procedures.
- 4.3. Information is accessed and documentation completed in accordance with workplace requirements.
RANGE STATEMENT
The range statement relates to the unit of competency as a whole. It allows for different work environments and situations that may affect performance. Bold italicised wording, if used in the performance criteria, is detailed below. Essential operating conditions that may be present with training and assessment (depending on the work situation, needs of the candidate, accessibility of the item, and local industry and regional contexts) may also be included.
Safety (OHS) is to be in accordance with commonwealth, state and territory legislation and regulations and may include:
handling of materials
hazard control
personal protective clothing and equipment prescribed under legislation, regulations and workplace policies and practices
safe operating procedures, including recognising and preventing hazards associated with:
hazardous materials and substances
service lines
surrounding structures and facilities
trip hazards
use of tools and equipment
work site visitors and the public
working at heights
working in proximity to others
use of firefighting equipment
use of first aid equipment
workplace environment and safety.
Environmental requirements include:
clean-up protection
waste management.
Quality assurance requirements may include:
Australian standards
Environment Protection Authority (EPA)
internal company quality assurance policy and risk management strategy
International Standards Organisation
site safety plan
workplace operations and procedures.
Materials for installing LPG storage facilities:
may include:
container supports and bases
copper tubing
fitting and fixing materials
gas cylinders and storage tanks
gas regulators
non-metallic hose assemblies
stainless steel
other approved materials
are to comply with job specifications and appropriate standards for the storage of LPG.
Statutory and regulatory authorities include:
state or territory statutory authority
statutory gasfitting authority
statutory plumbing authority.
Tools and equipment may include:
chain blocks
forklifts
grinders
hacksaws
hand and power tools
hand trolleys
hoists and jacks
lifting and load shifting equipment
manual brazing equipment
measuring equipment
rollers
testing equipment.
Information may include:
charts and hand drawings
diagrams or sketches
instructions issued by authorised organisational or external personnel
job drawings
manufacturer specifications and instructions
material safety data sheets (MSDS)
memos
organisation work specifications and requirements
recognised formulas or tables accepted by the regulatory authority
regulatory and legislative requirements, particularly those pertaining to:
building codes
OHS and environmental requirements
plumbing and gasfitting authority regulations
relevant Australian standards
safe work procedures relating to determining requirements, and installing and testing LPG storage systems
signage
verbal, written and graphical instructions
work bulletins
work schedules, plans and specifications.
The range statement relates to the unit of competency as a whole. It allows for different work environments and situations that may affect performance. Bold italicised wording, if used in the performance criteria, is detailed below. Essential operating conditions that may be present with training and assessment (depending on the work situation, needs of the candidate, accessibility of the item, and local industry and regional contexts) may also be included.
Safety (OHS) is to be in accordance with commonwealth, state and territory legislation and regulations and may include:
handling of materials
hazard control
personal protective clothing and equipment prescribed under legislation, regulations and workplace policies and practices
safe operating procedures, including recognising and preventing hazards associated with:
hazardous materials and substances
service lines
surrounding structures and facilities
trip hazards
use of tools and equipment
work site visitors and the public
working at heights
working in proximity to others
use of firefighting equipment
use of first aid equipment
workplace environment and safety.
Environmental requirements include:
clean-up protection
waste management.
Quality assurance requirements may include:
Australian standards
Environment Protection Authority (EPA)
internal company quality assurance policy and risk management strategy
International Standards Organisation
site safety plan
workplace operations and procedures.
Materials for installing LPG storage facilities:
may include:
container supports and bases
copper tubing
fitting and fixing materials
gas cylinders and storage tanks
gas regulators
non-metallic hose assemblies
stainless steel
other approved materials
are to comply with job specifications and appropriate standards for the storage of LPG.
Statutory and regulatory authorities include:
state or territory statutory authority
statutory gasfitting authority
statutory plumbing authority.
Tools and equipment may include:
chain blocks
forklifts
grinders
hacksaws
hand and power tools
hand trolleys
hoists and jacks
lifting and load shifting equipment
manual brazing equipment
measuring equipment
rollers
testing equipment.
Information may include:
charts and hand drawings
diagrams or sketches
instructions issued by authorised organisational or external personnel
job drawings
manufacturer specifications and instructions
material safety data sheets (MSDS)
memos
organisation work specifications and requirements
recognised formulas or tables accepted by the regulatory authority
regulatory and legislative requirements, particularly those pertaining to:
building codes
OHS and environmental requirements
plumbing and gasfitting authority regulations
relevant Australian standards
safe work procedures relating to determining requirements, and installing and testing LPG storage systems
signage
verbal, written and graphical instructions
work bulletins
work schedules, plans and specifications.
EVIDENCE GUIDE
The evidence guide provides advice on assessment and must be read in conjunction with the performance criteria, required skills and knowledge, range statement and the Assessment Guidelines for the Training Package.
Overview of assessment
This unit of competency could be assessed in the workplace or a close simulation of the workplace environment providing that simulated or project-based assessment techniques fully replicate plumbing and services workplace conditions, materials, activities, responsibilities and procedures.
Critical aspects for assessment and evidence required to demonstrate competency in this unit
A person who demonstrates competency in this unit must be able to provide evidence of:
locating, interpreting and applying relevant information, standards and specifications to determine requirements, and select, locate, install and test LPG storage systems
applying safety requirements throughout the work sequence, including the use of personal protective clothing and equipment
as a minimum the ability to, given the plans and specifications, determine the LPG storage requirements, and install and test two LPG storage facilities of less than 500 litre capacity, one being a multiple cylinder installation, ensuring:
correct identification of location, design and details of proposed storage installation
correct selection and use of appropriate processes, tools and equipment
completing all work to specification
compliance with regulations, standards and organisational quality procedures and processes
communicating and working effectively and safely with others.
Context of and specific resources for assessment
This competency is to be assessed using standard and authorised work practices, safety requirements and environmental constraints.
Assessment of essential underpinning knowledge will usually be conducted in an off-site context.
Assessment is to comply with relevant regulatory or Australian standards' requirements.
Resource implications for assessment include:
an induction procedure and requirement
realistic tasks or simulated tasks covering the minimum task requirements
relevant specifications and work instructions
tools and equipment appropriate to applying safe work practices
support materials appropriate to activity
workplace instructions relating to safe working practices and addressing hazards and emergencies
material safety data sheets
research resources, including industry related systems information.
Reasonable adjustments for people with disabilities must be made to assessment processes where required. This could include access to modified equipment and other physical resources, and the provision of appropriate assessment support.
Method of assessment
Assessment methods must:
satisfy the endorsed Assessment Guidelines of the Construction, Plumbing and Services Training Package
include direct observation of tasks in real or simulated work conditions, with questioning to confirm the ability to consistently identify and correctly interpret the essential underpinning knowledge required for practical application
reinforce the integration of employability skills with workplace tasks and job roles
confirm that competency is verified and able to be transferred to other circumstances and environments.
Validity and sufficiency of evidence requires that:
competency will need to be demonstrated over a period of time reflecting the scope of the role and the practical requirements of the workplace
where the assessment is part of a structured learning experience the evidence collected must relate to a number of performances assessed at different points in time and separated by further learning and practice, with a decision on competency only taken at the point when the assessor has complete confidence in the person's demonstrated ability and applied knowledge
all assessment that is part of a structured learning experience must include a combination of direct, indirect and supplementary evidence.
Assessment processes and techniques should as far as is practical take into account the language, literacy and numeracy capacity of the candidate in relation to the competency being assessed.
Supplementary evidence of competency may be obtained from relevant authenticated documentation from third parties, such as existing supervisors, team leaders or specialist training staff.
The evidence guide provides advice on assessment and must be read in conjunction with the performance criteria, required skills and knowledge, range statement and the Assessment Guidelines for the Training Package.
Overview of assessment
This unit of competency could be assessed in the workplace or a close simulation of the workplace environment providing that simulated or project-based assessment techniques fully replicate plumbing and services workplace conditions, materials, activities, responsibilities and procedures.
Critical aspects for assessment and evidence required to demonstrate competency in this unit
A person who demonstrates competency in this unit must be able to provide evidence of:
locating, interpreting and applying relevant information, standards and specifications to determine requirements, and select, locate, install and test LPG storage systems
applying safety requirements throughout the work sequence, including the use of personal protective clothing and equipment
as a minimum the ability to, given the plans and specifications, determine the LPG storage requirements, and install and test two LPG storage facilities of less than 500 litre capacity, one being a multiple cylinder installation, ensuring:
correct identification of location, design and details of proposed storage installation
correct selection and use of appropriate processes, tools and equipment
completing all work to specification
compliance with regulations, standards and organisational quality procedures and processes
communicating and working effectively and safely with others.
Context of and specific resources for assessment
This competency is to be assessed using standard and authorised work practices, safety requirements and environmental constraints.
Assessment of essential underpinning knowledge will usually be conducted in an off-site context.
Assessment is to comply with relevant regulatory or Australian standards' requirements.
Resource implications for assessment include:
an induction procedure and requirement
realistic tasks or simulated tasks covering the minimum task requirements
relevant specifications and work instructions
tools and equipment appropriate to applying safe work practices
support materials appropriate to activity
workplace instructions relating to safe working practices and addressing hazards and emergencies
material safety data sheets
research resources, including industry related systems information.
Reasonable adjustments for people with disabilities must be made to assessment processes where required. This could include access to modified equipment and other physical resources, and the provision of appropriate assessment support.
Method of assessment
Assessment methods must:
satisfy the endorsed Assessment Guidelines of the Construction, Plumbing and Services Training Package
include direct observation of tasks in real or simulated work conditions, with questioning to confirm the ability to consistently identify and correctly interpret the essential underpinning knowledge required for practical application
reinforce the integration of employability skills with workplace tasks and job roles
confirm that competency is verified and able to be transferred to other circumstances and environments.
Validity and sufficiency of evidence requires that:
competency will need to be demonstrated over a period of time reflecting the scope of the role and the practical requirements of the workplace
where the assessment is part of a structured learning experience the evidence collected must relate to a number of performances assessed at different points in time and separated by further learning and practice, with a decision on competency only taken at the point when the assessor has complete confidence in the person's demonstrated ability and applied knowledge
all assessment that is part of a structured learning experience must include a combination of direct, indirect and supplementary evidence.
Assessment processes and techniques should as far as is practical take into account the language, literacy and numeracy capacity of the candidate in relation to the competency being assessed.
Supplementary evidence of competency may be obtained from relevant authenticated documentation from third parties, such as existing supervisors, team leaders or specialist training staff.
Replaces
| State Code | National Code | Title | Type |
|---|---|---|---|
| W2754 | BCPGS3014A | Calculate and install natural ventilation for Type A gas appliances | Unit of competency |
Replaced By
| State Code | National Code | Title | Type |
|---|---|---|---|
| D7461 | CPCPGS3024A | Calculate and install natural ventilation for Type A gas appliances | Unit of competency |
| State Code | National Code | Title | Type |
|---|---|---|---|
| W603 | CPC32708 | Certificate III in Gas Fitting | Qualification |
| W600 | CPC32408 | Certificate III in Plumbing | Qualification |