Whilst all efforts are made to provide accurate and timely information from the relevant source/documentation, please be aware that the information supplied may not be the most current version. The accuracy of the detail has not been confirmed by the Department and therefore should not be relied upon without first confirming the contents.

Operate stand alone signalling/points control equipment

Operate stand alone signalling/points control equipment

Unit of competency
National Code
TLIW3026B
State Code
WG247
TGA Status
Replaced
DTWD Status
Replaced
Current Release Number
1.00
Current Release Date
21/04/2013
State Implementation and Classification
Approved Date
04/11/2014
Field of Education
030717 - Plant And Machine Operations
Original Release Date
04/11/2014
Nominal Hours
10
Description
This unit involves the skills and knowledge required to operate stand alone signalling/point control equipment on a rail network in accordance with Access Provider legislative and regulatory requirements. Licensing or certification requirements are not applicable to this unit.
Notes
Elements and Performance Criteria
1 Use stand alone signalling control equipment
  • 1.1 Signalling/point control equipment is identified and confirmed with network control officer, if applicable
  • 1.2 Authority to operate signalling/point control equipment is obtained from network control officer
  • 1.3 Appropriate personal protective equipment (PPE) is worn in accordance with Access Provider and organisational requirements
  • 1.4 Track environment is accessed safely in accordance with workplace procedures
  • 1.5 Changed local conditions are identified
  • 1.6 Stand alone signalling control equipment is operated safely in accordance with any local instructions
  • 1.7 Route is set and confirmed as correct to facilitate safe rail vehicle movement
  • 1.8 Communication with network control officer is maintained using appropriate communication protocols and systems in accordance with workplace procedures
  • 1.9 Unsafe situations and/or emergencies are identified and appropriate action is taken in accordance with workplace procedures
2 Restore stand alone signalling control equipment
  • 2.1 Network control officer is informed when rail vehicle/s are clear of fouling points
  • 2.2 Stand alone signalling/point control equipment is restored to correct position
  • 2.3 Restoration is confirmed with network control officer
  • 2.4 Where required, signalling/point control equipment is locked and secured in accordance with workplace procedures
  • 2.5 Any identified equipment faults are reported in accordance with workplace procedures
The range statement relates to the unit of competency as a whole. It allows for different work environments and situations that may affect performance.
Work locations may include:
rail corridor
danger zone:
running line
sidings/yards
platforms/buildings
Terminology will be:
as defined by the Access Provider
Work may occur:
by day or night
under varied weather conditions and situations
Safety assessment will be:
as defined within workplace procedures
as defined in the safety assessment for work including:
view - line of sight
direction of approaching trains
speed of approaching trains
position of safety
changed local conditions
Network control officer may be:
network controller
train controller
area controller
signaller
Communication may include:
receiving and passing on verbal messages/information
reporting unsafe situations and responding to emergencies
general safety and emergency messages
Communication protocols and systems may include:
general safety
transmitting and receiving messages:
identification
standard radio terms
phonetic alphabet
testing communications equipment
emergency messages
Safety clothing and equipment may include:
high visibility clothing
protective footwear
hearing protection
Rail vehicles may include:
trains
road/rail vehicles
track vehicles
Stand alone signalling equipment may include:
dual control point machines
ground frames
switchlocks
plunger lock points
small signal boxes
quadrant levers
master keys
tokens
Annett keys
The evidence guide provides advice on assessment and must be read in conjunction with the performance criteria, required knowledge and skills, the range statement and the assessment guidelines for this Training Package.
Critical aspects for assessment and evidence required to demonstrate competency in this unit
The evidence required to demonstrate competency in this unit must be relevant to and satisfy all of the requirements of the elements and performance criteria of this unit and include demonstration of applying:
the required knowledge and skills
relevant workplace rules and procedures
other relevant aspects of the range statement
Assessment must include exercises which demonstrate competent performance of the following in a range of situations:
explaining procedures to maintain communication with network control officer
selecting and wearing appropriate PPE
correctly operating stand alone signalling and point control equipment
correctly restoring stand alone signalling and point control equipment
demonstrating locking and, where required, securing stand alone signalling control equipment in accordance with workplace procedures
Context of and specific resources for assessment
Performance is demonstrated in a suitable context
Resources for assessment include:
a range of relevant exercises and/or other simulated practical and knowledge assessment, and/or
access to an appropriate range of relevant operational situations in the workplace
In both real and simulated environments, access is required to:
relevant and appropriate materials and equipment, and
applicable documentation including workplace procedures, regulations, codes of practice and operation manuals
Method of assessment
Assessment of knowledge must be conducted through appropriate written/oral tests
Practical assessment must occur:
through activities in an appropriately simulated environment, and/or
in an appropriate range of situations in the workplace
Replaces
State Code National Code Title Type
D5386 TLIW3026A Operate stand alone signalling/point control equipment Unit of competency
Replaced By
State Code National Code Title Type
AVH33 TLIW3026 Operate stand alone signalling/point control equipment Unit of competency