Whilst all efforts are made to provide accurate and timely information from the relevant source/documentation, please be aware that the information supplied may not be the most current version. The accuracy of the detail has not been confirmed by the Department and therefore should not be relied upon without first confirming the contents.

Terminate metallic conductor cable

Terminate metallic conductor cable

Unit of competency
National Code
ICTTC008D
State Code
D2061
TGA Status
Replaced
DTWD Status
Replaced
Current Release Number
1.00
Current Release Date
08/01/2009
State Implementation and Classification
Approved Date
18/08/2009
Field of Education
031309 - Communications Equipment Installation And Maintenance
Original Release Date
18/08/2009
Nominal Hours
60
Description
This unit applies to all contexts for indoor and outdoor installation within a customer premises and applies to both customer premises cabling and customer premises equipment.This unit applies to all communications applications whether digital or analogue including telephony, data, video including digital broadcasting, computer networks including LANs and WANs, and multi media.This unit may be applied to domestic, commercial or industrial installations.This unit applies to all metallic conductor cable types including coaxial and structured (Category 5 or Category 6, 6A, 7 or 7A,) cabling. It also applies to the joining of cable in a terminating block (in/out block). Specific units of competency apply to the placing, securing and termination of particular cable types and should be used in association with this unit where applicable.Assessment by a TITAB registered assessor is recommended.The six unit competency set ICTTC005D, ICTTC006D, ICTTC008D, ICTTC012D, ICTTC017D and ICTTC022D that meets the Australian Communications and Media Authoritys (ACMA) requirements for Cabling Provider Registration (CPR), is generally used as part of a more specialised customer cabling qualification. This set is usually regarded as more suitable for new entrants where limited industry experience has been obtained and forms the major part of specialised qualifications such as ICT20308 Certificate II in Telecommunications Cabling. When these six units are delivered as a set within state/territory funding approved programs, the two benchmark CPR units (ICTTC136C and ICTTC137C) are not required. This unit applies to all contexts for indoor and outdoor installation within a customer premises and applies to both customer premises cabling and customer premises equipment.This unit applies to all communications applications whether digital or analogue including telephony, data, video including digital broadcasting, computer networks including LANs and WANs, and multi media.This unit may be applied to domestic, commercial or industrial installations.This unit applies to all metallic conductor cable types including coaxial and structured (Category 5 or Category 6, 6A, 7 or 7A,) cabling. It also applies to the joining of cable in a terminating block (in/out block). Specific units of competency apply to the placing, securing and termination of particular cable types and should be used in association with this unit where applicable.Assessment by a TITAB registered assessor is recommended.The six unit competency set ICTTC005D, ICTTC006D, ICTTC008D, ICTTC012D, ICTTC017D and ICTTC022D that meets the Australian Communications and Media Authoritys (ACMA) requirements for Cabling Provider Registration (CPR), is generally used as part of a more specialised customer cabling qualification. This set is usually regarded as more suitable for new entrants where limited industry experience has been obtained and forms the major part of specialised qualifications such as ICT20308 Certificate II in Telecommunications Cabling. When these six units are delivered as a set within state/territory funding approved programs, the two benchmark CPR units (ICTTC136C and ICTTC137C) are not required.
Notes
Elements and Performance Criteria
1 Identify termination system
  • 1.1 Identify correct termination requirements for installation
  • 1.2 Select termination system to meet customer performance needs
  • 1.3 Termination system conforms to work specifications and relevant industry standards
2 Set up suitable work area
  • 2.1 Remove all contaminants from work site that may adversely effect termination
  • 2.2 Work site has adequate visibility to minimise errors and reduce eye strain
  • 2.3 Work site is safe and secure
  • 2.4 All required tools and equipment are available and in a safe working order and adjusted to manufacturers specifications
3 Plan frame/outlet layout
  • 3.1 Design cable and block location within frame with capacity for expansion where possible
  • 3.2 Segregate incoming and outgoing cables for ease of access and to minimise overlaying and backtracking of cable
  • 3.3 Check environmental conditions are suitable for termination
  • 3.4 Terminating equipment layout is systematic and follows relevant industry codes of practice and standards, and customer requirements where appropriate
  • 3.5 Back-mount or outlet layout conforms to manufacturers specifications
  • 3.6 Layout allows for adequate workspace to ensure ease of access for installation and service purposes
4 Prepare cable for termination
  • 4.1 Remove cable sheath to allow for conductor length and installation requirements
  • 4.2 Handle cable strictly in accordance with manufacturers specifications
  • 4.3 Conductors, sheath and insulation are not damaged during preparation
  • 4.4 Work in a safe manner to manufacturers specifications
  • 4.5 Layer out cable out by reference to manufacturers coding system to ensure correct terminating sequence and unique identification where appropriate
  • 4.6 Fit over voltage protection devices to all cables with metallic component where required
5 Terminate conductors
  • 5.1 Install terminating modules to frame in accordance with manufacturers specifications
  • 5.2 Fan cable pairs neatly to termination equipment to facilitate accurate termination
  • 5.3 Terminate cable to manufacturers specifications using correct tool
  • 5.4 Earth cable shield to manufacturers specifications and industry standards
  • 5.5 Confirm that the termination colour code sequence has been followed by visual inspection
6 Label and document pair location
  • 6.1 Label cable pairs promptly and clearly to provide for accurate identification in accordance with manufacturers requirements and industry standards
  • 6.2 Update record books and plans to show pair locations in accordance with industry codes of practice
7 Clean up work site
  • 7.1 Clean and adjust all tools and equipment and store in an accessible location
  • 7.2 Remove installation waste and debris from work site and dispose of in accordance with environmental requirements to maintain safe worksite conditions
8 Manage Remote Power Feed
  • 8.1 Identify the risks posed by contact with Remote Power Feeding services
  • 8.2 Identify Remote Power Feeding services in a range of commonly encountered circumstances inside customer premises
The range statement relates to the unit of competency as a whole. It allows for different work environments and situations that may affect performance. Bold italicised wording, if used in the performance criteria, is detailed below. Essential operating conditions that may be present with training and assessment (depending on the work situation, needs of the candidate, accessibility of the item, and local industry and regional contexts) may also be included.
Strategies to manage infrastructure
Appropriate separations, fastening techniques, correct use of cable trays and support systems


Cable termination
May occur at a frame or outlet location


Cable termination:
Is usually done individually


Termination systems:
May be manufacturers proprietary systems


Work site contaminants
Include: dust, water, paint, building debris, asbestos


Cable conductor identification codes
May be: colour coded, banded, numbered, lettered


Record
May be: record cards, record books, cable drawings, cable plans


Site access approval
May be verbal or written


Site security systems
May include: registered entry requirements, electronic surveillance, security clearance


Site requirements
May include: noise control, relationships with other customer activities, presentation, access and egress points


Customers specifications for support systems
May be found in: contract documents, cable plans and designs, specification schedules


Safe working practices
Includes the safe use and handling of: tools and equipment, materials, chemicals and work platforms


Work platforms
May be: ladders, scaffold, scissor lifts ('cherry pickers)


Tools
May be: hand or power and include manufacturers proprietary terminating tools


Manufacturers specifications
May be found in printed instruction leaflets or pre printed on materials or on product packaging


Industry standards
May include regulated or industry codes of practice and include appropriate ACMA technical standards


All cable used
Must be compliant with appropriate ACMA technical standard requirements (eg. for underground, aerial, Category 5 or like Category 6, 6A, 7 or 7A, UTP etc)


All cabling products other than cable must be:
ACMA approved


Remote Power Feed
Applies to telecommunications services which operate at above TNV (Telecommunications Network Voltage)


Relevant legislation, codes, regulations and standards
Include:
Technical Standards AS/ACIF S008:2006, AS/ACIF S009:2006
AS Communications Cabling Manaul (CCM) Volume 1
ACIF Standards and Codes
AS/NZS 3000:2007
AS/NZS 3080:2003

AS/NZS 3084:2003
AS/NZS 3085.1:2004
AS/NZS ISO/IEC 15018:2005
AS/NZS ISO/IEC 24702:2007
AS/NZS IEC 61935.1:2006
AS/NZS IEC 61935.2:2006
AS/NZS ISO/IEC 14763.3:2007
ISO Draft 11801 (International)
Cabling security codes and regulations
The evidence guide provides advice on assessment and must be read in conjunction with the performance criteria, required skills and knowledge, range statement and the Assessment Guidelines for the Training Package.
Critical aspects for assessment and evidence required to demonstrate competency in this unit
Evidence of the following is essential:
demonstration of a minimum of at least one manufacturer's termination system at both frame and outlet locations and at least 1-50 pair cable
ability to read and interpret cable drawings and plans for locations and terminations
accurate application of cable conductor identification codes
application of all related OHS requirements and work practices (including protective clothing and personal safety items)
safe use of general hand and power tools and general equipment normally related to these tasks
correct interpretation and application of related regulations and/or industry codes
interpersonal skills related to clients, employer, supervisors, work associates, team members, other contractors


Context of and specific resources for assessment
Assessment must ensure:
A workplace conducting the operations covered by this competency unit, equipment and resources relevant to the context of the work (See Range Statement) and support from a competent supervisor or mentor.
OR
A simulated environment with similar provisions which conforms to the Assessment Guidelines.


Guidance information for assessment
Access must be provided to appropriate learning and assessment support when required.
Assessment processes and techniques must be culturally appropriate, and appropriate to the oral communication skill level, and language and literacy capacity of the candidate and the work being performed.
In all cases where practical assessment is used it will be combined with targeted questioning to assess underpinning knowledge.
Replaces
State Code National Code Title Type
W0585 ICTTC008C Terminate metallic conductor cable Unit of competency
Replaced By
State Code National Code Title Type
D3300 ICTCBL2008A Terminate metallic conductor customer cable Unit of competency