Unit of competency Outline
Date retreived
22/07/2026 11:41 AM AWST
22/07/2026 11:41 AM AWST
Whilst all efforts are made to provide accurate and timely information from the relevant source/documentation, please be aware that the information supplied may not be the most current version. The accuracy of the detail has not been confirmed by the Department and therefore should not be relied upon without first confirming the contents.
Connect and install storage tanks to a domestic water supply
Connect and install storage tanks to a domestic water supply
Unit of competency
National Code
CPCPWT3010A
CPCPWT3010A
State Code
D7498
D7498
TGA Status
Replaced
Replaced
DTWD Status
Replaced
Replaced
State Implementation and Classification
Approved Date
11/10/2011
Field of Education
040327 - Plumbing
Original Release Date
11/10/2011
Nominal Hours
20
Description
This unit of competency specifies the outcomes required to connect and install storage tanks to a domestic water supply.
Notes
Elements and Performance Criteria
1. Prepare for work.
- 1.1. Plans and specifications are obtained.1.2. Safety (OHS) and workplace environmental requirements associated with connecting static storage tanks to a water supply system are followed.1.3. Quality assurance requirements are identified and followed in accordance with workplace requirements.1.4. Tasks are planned and sequenced in conjunction with others involved in or affected by the work.1.5. Tools and equipment, including personal protective equipment, are selected and checked for serviceability.1.6. Work area is prepared to support efficient connection and installation.
2. Identify installation requirements.
- 2.1. Required materials that comply with relevant Australian standards and job specifications are determined from plans and specification.2.2. Sustainabilityprinciples and concepts are applied to work preparation and application.2.3. Quantities of required materials are calculated from plans and specifications.2.4. Materials and equipment are ordered and collected according to workplace procedures.2.5. Materials and equipment are checked for compliance with relevant Australian standards, docket and order form, and for acceptable condition.
3. Install and test storage tank.
- 3.1. Storage tank and associated pipework are set out in accordance with plans, specifications and job instructions.3.2. Pipe supports and fixings, compliant with relevant Australian standards, are installed to plans and manufacturer specifications.3.3. Tank, piping and materials are installed in accordance with plans, specifications and relevant Australian standards.3.4. Jointing systems are confirmed as compliant with relevant Australian standards.3.5. Installed system is pressure tested and commissioned in accordance with relevant Australian standards and job specifications.3.6. Test data is recorded in format required by job specifications and quality assurance procedures.
4. Clean up.
- 4.1. Work area is cleared, and materials disposed of, reused or recycled in accordance with legislation, regulations, codes of practice and job specifications.4.2. Tools and equipment are cleaned, checked, maintained and stored in accordance with manufacturer recommendations and workplace procedures.4.3. Information is accessed and documentation completed in accordance with regulatory authorities and workplace requirements.
RANGE STATEMENT
The range statement relates to the unit of competency as a whole. It allows for different work environments and situations that may affect performance. Bold italicised wording, if used in the performance criteria, is detailed below. Essential operating conditions that may be present with training and assessment (depending on the work situation, needs of the candidate, accessibility of the item, and local industry and regional contexts) may also be included.
Safety (OHS) is to be in accordance with commonwealth, state and territory legislation and regulations and may include:
handling materials
hazard control
personal protective clothing and equipment prescribed under legislation, regulations and workplace policies and practices
safe operating procedures, including recognising and preventing hazards associated with:
electricity
hazardous materials and substances
service lines
surrounding structures and facilities
trip hazards
use of tools and equipment
work site visitors and the public
working at heights
working in proximity to others
use of firefighting equipment
use of first aid equipment
workplace environment and safety.
Environmental requirements cover water quality management and may include:
clean-up protection
stormwater protection
waste management.
Quality assurance requirements may include:
Australian standards
Environment Protection Authority (EPA)
environment policy
internal company quality assurance policy and risk management strategy
International Standards Organisation
site safety plan
workplace operations and procedures.
Tools and equipment may include:
chain blocks
cutting and threading equipment
elevated work platforms
forklifts
hand and mechanical excavation equipment
hand and power tools
hand trolleys
hoists and jacks
ladders
lifting and load shifting equipment
rollers
scaffolds
testing equipment
trench shoring equipment
welding equipment.
Materials may include:
copper, brass, polymer or cement lined cast iron pipes
fibre glass, steel or polymer storage tanks
other approved pipes and materials.
Sustainability principles and concepts:
cover the current and future social, economic and environmental use of resources
may include:
appropriate material selection that has minimal environmental impact
efficient energy and water use
efficient use and recycling of material, including minimising evaporation
siting of tank
overflow disposal and reuse
disposal of waste material to ensure minimal environmental impact.
Information may include:
charts and hand drawings
plans or sketches
instructions issued by authorised organisational or external personnel
manufacturer specifications and instructions
material safety data sheets (MSDS)
memos
organisation work specifications and requirements
regulatory and legislative requirements, particularly those pertaining to:
building codes
OHS and environmental requirements
plumbing regulations
relevant Australian standards
safe work procedures relating to connecting static storage tanks
signage
verbal, written and graphical instructions
work bulletins
work schedules, plans and specifications.
The range statement relates to the unit of competency as a whole. It allows for different work environments and situations that may affect performance. Bold italicised wording, if used in the performance criteria, is detailed below. Essential operating conditions that may be present with training and assessment (depending on the work situation, needs of the candidate, accessibility of the item, and local industry and regional contexts) may also be included.
Safety (OHS) is to be in accordance with commonwealth, state and territory legislation and regulations and may include:
handling materials
hazard control
personal protective clothing and equipment prescribed under legislation, regulations and workplace policies and practices
safe operating procedures, including recognising and preventing hazards associated with:
electricity
hazardous materials and substances
service lines
surrounding structures and facilities
trip hazards
use of tools and equipment
work site visitors and the public
working at heights
working in proximity to others
use of firefighting equipment
use of first aid equipment
workplace environment and safety.
Environmental requirements cover water quality management and may include:
clean-up protection
stormwater protection
waste management.
Quality assurance requirements may include:
Australian standards
Environment Protection Authority (EPA)
environment policy
internal company quality assurance policy and risk management strategy
International Standards Organisation
site safety plan
workplace operations and procedures.
Tools and equipment may include:
chain blocks
cutting and threading equipment
elevated work platforms
forklifts
hand and mechanical excavation equipment
hand and power tools
hand trolleys
hoists and jacks
ladders
lifting and load shifting equipment
rollers
scaffolds
testing equipment
trench shoring equipment
welding equipment.
Materials may include:
copper, brass, polymer or cement lined cast iron pipes
fibre glass, steel or polymer storage tanks
other approved pipes and materials.
Sustainability principles and concepts:
cover the current and future social, economic and environmental use of resources
may include:
appropriate material selection that has minimal environmental impact
efficient energy and water use
efficient use and recycling of material, including minimising evaporation
siting of tank
overflow disposal and reuse
disposal of waste material to ensure minimal environmental impact.
Information may include:
charts and hand drawings
plans or sketches
instructions issued by authorised organisational or external personnel
manufacturer specifications and instructions
material safety data sheets (MSDS)
memos
organisation work specifications and requirements
regulatory and legislative requirements, particularly those pertaining to:
building codes
OHS and environmental requirements
plumbing regulations
relevant Australian standards
safe work procedures relating to connecting static storage tanks
signage
verbal, written and graphical instructions
work bulletins
work schedules, plans and specifications.
EVIDENCE GUIDE
The evidence guide provides advice on assessment and must be read in conjunction with the performance criteria, required skills and knowledge, range statement and the Assessment Guidelines for the Training Package.
Overview of assessment
This unit of competency could be assessed in the workplace or a close simulation of the workplace environment providing that simulated or project-based assessment techniques fully replicate plumbing and services workplace conditions, materials, activities, responsibilities and procedures.
Critical aspects for assessment and evidence required to demonstrate competency in this unit
A person who demonstrates competency in this unit must be able to provide evidence of the ability to:
locate, interpret and appl relevant information, Australian standards and specifications to connect static water storage tanks
apply safety requirements throughout the work sequence, including electrical requirements and the use of personal protective clothing and equipment
connect residential or commercial static water storage tanks in accordance with backflow protection principles
as a minimum, given the plans and specifications, connect and commission an approved static water storage tank to a residential or commercial water distribution pipe system to include correct air gap, operational water level, overflow requirements, minimum outlet size, tank placement, safe tray and safe waste (to meet the specified location and installation requirements) ensuring:
correct identification of requirements, design and details of the proposed installation
correct selection and use of appropriate processes, tools and equipment
completion of all work to specification
compliance with regulations, relevant Australian standards, and organisational quality procedures and processes
application of sustainability principles and concepts
communicate and work effectively and safely with others.
Context of and specific resources for assessment
This unit of competency is to be assessed using relevant Australian standards and authorised work practices, safety requirements and environmental constraints.
Assessment of essential underpinning knowledge will usually be conducted in an off-site context.
Assessment is to comply with relevant regulatory or Australian standards requirements.
Resource implications for assessment include:
an induction procedure and requirement
realistic tasks or simulated tasks covering the minimum task requirements
relevant specifications and work instructions
tools and equipment appropriate to applying safe work practices
support materials appropriate to activity
workplace instructions relating to safe working practices and addressing hazards and emergencies
MSDS
research resources, including industry related systems information.
Reasonable adjustments for people with disabilities must be made to assessment processes where required. This could include access to modified equipment and other physical resources, and the provision of appropriate assessment support.
Method of assessment
Assessment methods must:
satisfy the endorsed Assessment Guidelines of the Construction, Plumbing and Services Training Package
include direct observation of tasks in real or simulated work conditions, with questioning to confirm the ability to consistently identify and correctly interpret the essential underpinning knowledge required for practical application
reinforce the integration of employability skills with workplace tasks and job roles
confirm that competency is verified and able to be transferred to other circumstances and environments.
Validity and sufficiency of evidence requires that:
competency will need to be demonstrated over a period of time reflecting the scope of the role and the practical requirements of the workplace
where the assessment is part of a structured learning experience the evidence collected must relate to a number of performances assessed at different points in time and separated by further learning and practice, with a decision on competency only taken at the point when the assessor has complete confidence in the person's demonstrated ability and applied knowledge
all assessment that is part of a structured learning experience must include a combination of direct, indirect and supplementary evidence.
Assessment processes and techniques should as far as is practical take into account the language, literacy and numeracy capacity of the candidate in relation to the competency being assessed.
Supplementary evidence of competency may be obtained from relevant authenticated documentation from third parties, such as existing supervisors, team leaders or specialist training staff.
Guidance information for assessment
This unit could be assessed on its own or in combination with other units relevant to the job function, for example:
CPCPRF2013A Collect and store roof water
CPCPWT3013A Install and commission water heating systems.
The evidence guide provides advice on assessment and must be read in conjunction with the performance criteria, required skills and knowledge, range statement and the Assessment Guidelines for the Training Package.
Overview of assessment
This unit of competency could be assessed in the workplace or a close simulation of the workplace environment providing that simulated or project-based assessment techniques fully replicate plumbing and services workplace conditions, materials, activities, responsibilities and procedures.
Critical aspects for assessment and evidence required to demonstrate competency in this unit
A person who demonstrates competency in this unit must be able to provide evidence of the ability to:
locate, interpret and appl relevant information, Australian standards and specifications to connect static water storage tanks
apply safety requirements throughout the work sequence, including electrical requirements and the use of personal protective clothing and equipment
connect residential or commercial static water storage tanks in accordance with backflow protection principles
as a minimum, given the plans and specifications, connect and commission an approved static water storage tank to a residential or commercial water distribution pipe system to include correct air gap, operational water level, overflow requirements, minimum outlet size, tank placement, safe tray and safe waste (to meet the specified location and installation requirements) ensuring:
correct identification of requirements, design and details of the proposed installation
correct selection and use of appropriate processes, tools and equipment
completion of all work to specification
compliance with regulations, relevant Australian standards, and organisational quality procedures and processes
application of sustainability principles and concepts
communicate and work effectively and safely with others.
Context of and specific resources for assessment
This unit of competency is to be assessed using relevant Australian standards and authorised work practices, safety requirements and environmental constraints.
Assessment of essential underpinning knowledge will usually be conducted in an off-site context.
Assessment is to comply with relevant regulatory or Australian standards requirements.
Resource implications for assessment include:
an induction procedure and requirement
realistic tasks or simulated tasks covering the minimum task requirements
relevant specifications and work instructions
tools and equipment appropriate to applying safe work practices
support materials appropriate to activity
workplace instructions relating to safe working practices and addressing hazards and emergencies
MSDS
research resources, including industry related systems information.
Reasonable adjustments for people with disabilities must be made to assessment processes where required. This could include access to modified equipment and other physical resources, and the provision of appropriate assessment support.
Method of assessment
Assessment methods must:
satisfy the endorsed Assessment Guidelines of the Construction, Plumbing and Services Training Package
include direct observation of tasks in real or simulated work conditions, with questioning to confirm the ability to consistently identify and correctly interpret the essential underpinning knowledge required for practical application
reinforce the integration of employability skills with workplace tasks and job roles
confirm that competency is verified and able to be transferred to other circumstances and environments.
Validity and sufficiency of evidence requires that:
competency will need to be demonstrated over a period of time reflecting the scope of the role and the practical requirements of the workplace
where the assessment is part of a structured learning experience the evidence collected must relate to a number of performances assessed at different points in time and separated by further learning and practice, with a decision on competency only taken at the point when the assessor has complete confidence in the person's demonstrated ability and applied knowledge
all assessment that is part of a structured learning experience must include a combination of direct, indirect and supplementary evidence.
Assessment processes and techniques should as far as is practical take into account the language, literacy and numeracy capacity of the candidate in relation to the competency being assessed.
Supplementary evidence of competency may be obtained from relevant authenticated documentation from third parties, such as existing supervisors, team leaders or specialist training staff.
Guidance information for assessment
This unit could be assessed on its own or in combination with other units relevant to the job function, for example:
CPCPRF2013A Collect and store roof water
CPCPWT3013A Install and commission water heating systems.
Replaced By
| State Code | National Code | Title | Type |
|---|---|---|---|
| WF964 | CPCPWT3020A | Connect and install storage tanks to a domestic water supply | Unit of competency |
| State Code | National Code | Title | Type |
|---|---|---|---|
| D411 | CPC32411 | Certificate III in Plumbing | Qualification |