Whilst all efforts are made to provide accurate and timely information from the relevant source/documentation, please be aware that the information supplied may not be the most current version. The accuracy of the detail has not been confirmed by the Department and therefore should not be relied upon without first confirming the contents.

Conduct operational checks and carry out corrective action on in-service electrical plant

Conduct operational checks and carry out corrective action on in-service electrical plant

Unit of competency
National Code
UEPOPS452
State Code
OAG22
TGA Status
Replaced
DTWD Status
Replaced
Current Release Number
1.00
Current Release Date
31/10/2018
State Implementation and Classification
Approved Date
15/05/2019
Field of Education
080399 - Business And Management, N.e.c.
Original Release Date
15/05/2019
Nominal Hours
36
Description
This unit involves the skills and knowledge required to conduct operational checks and carry out corrective actions on in-service electrical plant.An operational check is the verification that a group of components or units are working together to accomplish a single objective. An operational check consists of running in-service electrical plant to ensure that all the systems function together. Competency in this unit requires the ability to plan for plant in-service checks,carry out in-service electrical checks,carry out corrective actions and complete work. Individuals will, in general, work as an operator in a power generation facility. Power generation plant operators are typically trained and authorised to isolate, prepare plant and issue permits to work.No licensing, legislative or certification requirements apply to this unit at the time of publication.Note: Workplace practicesThe application of the skills and knowledge described in this unit may require a licence or training permit to practice in the workplace where work is carried out on gas and electrical installations. Additional conditions may apply under state and territory legislative and regulatory licensing requirements.
Notes
Elements and Performance Criteria
1 Plan for plant in-service checks
  • 1.1 Safety issues and Work, Health and Safety (WHS)/Occupational Health and Safety (OHS) regulations are identified, in accordance with workplace procedures
  • 1.2 Work, electrical in-service plant and resource requirements are identified from relevant personnel, work orders and documentation, in accordance with workplace procedures
  • 1.3 Electrical in-service plant status and work requirements are confirmed with appropriate personnel or by site inspection, in accordance with workplace procedures
  • 1.4 Equipment is checked for correct calibration and operation and materials are obtained and inspected for compliance with job specification, in accordance with workplace procedures
  • 1.5 Potential hazards are identified and risk control measures are selected, in accordance with the workplace procedures
  • 1.6 Pre-access checks of electrical in-service plant are carried out, in accordance with workplace procedures and site requirements
2 Carry out in-service electrical checks
  • 2.1 Electrical in-service plant is operated, in accordance with workplace procedures and manufacturers' recommendations
  • 2.2 Electrical in-service plant checks are conducted and monitored, in accordance with workplace procedures, to detect deviations from normal operation parameters
  • 2.3 Electrical in-service checks are performed, in accordance with workplace procedures
  • 2.4 Electrical in-service plant integrity and personnel safety are maintained, in accordance with workplace procedures and in consultation with appropriate personnel and technical and operational documentation
3 Carry out corrective actions
  • 3.1 Corrective actions are identified after analysing electrical in-service plant operations, in accordance with manufacturers' recommendations and workplace procedures
  • 3.2 Isolations are confirmed, where appropriate, in accordance with workplace procedures and site requirements
  • 3.3 Equipment for use in conducting operational checks is modified using appropriate plans, drawings and manuals, in accordance with workplace procedures
  • 3.4 Corrective actions are carried out on electrical in-service plant, without damage or loss to other plant, in accordance with workplace procedures
  • 3.5 Modified electrical in-service plant is set up to meet operational parameters, in accordance with workplace procedures and manufacturers specifications
  • 3.6 Final electrical in-service plant inspection is performed, in accordance with workplace procedures
4 Complete work
  • 4.1 Operational checks and corrective actions are completed, and electrical in-service plant is returned to operational status, in accordance with workplace procedures
  • 4.2 Appropriate personnel are notified of work completion, in accordance with workplace procedures
  • 4.3 Electrical in-service plant problems and corrective actions are reported, in accordance with workplace procedures
No information
No information
Replaces
State Code National Code Title Type
WE429 UEPOPS452A Conduct operational checks and carry out corrective action on in-service electrical plant Unit of competency
Replaced By
State Code National Code Title Type
ODZ00 UEPOPS013 Conduct operational checks and carry out corrective action on in-service electrical plant Unit of competency