Whilst all efforts are made to provide accurate and timely information from the relevant source/documentation, please be aware that the information supplied may not be the most current version. The accuracy of the detail has not been confirmed by the Department and therefore should not be relied upon without first confirming the contents.
Establish the basic operating conditions of air conditioning systems
Establish the basic operating conditions of air conditioning systems
Unit of competency
National Code
UEERA0035
UEERA0035
State Code
OBY12
OBY12
TGA Status
Current
Current
DTWD Status
Approved
Approved
State Implementation and Classification
Approved Date
12/07/2021
Field of Education
031315 - Refrigeration And Air Conditioning Mechanics
Original Release Date
12/07/2021
Nominal Hours
18
Description
This unit involves the skills and knowledge required to determine operating conditions of air conditioning systems.It includes working safely; determining air temperature, air flow rates and relative humidity using measurement and calculation methods. The skills and knowledgein this unit will be applied by refrigeration and air conditioning technicians during the commissioning, service and repair of air conditioning systems.The skills and knowledge described in this unit may, in some jurisdictions, require a licence or permit to practice in the workplace subject to regulations for undertaking refrigeration and air conditioning work. Practice in the workplace and during training is also subject to work health and safety (WHS)/occupational health and safety (OHS) regulations.
Notes
Elements and Performance Criteria
1 Prepare to determine operating conditions of air conditioning system
- 1.1 WHS/OHS hazards, risk control methods, relevant standards, codes and legislation are obtained and applied in accordance with workplace procedures
- 1.2 Safety hazards which have not previously been identified are assessed, reported and advice on risk control measures is sought from supervisor
- 1.3 System design operating conditions are obtained from documentation or supervisor to determine scope of work to be undertaken
- 1.4 Advice is sought from the supervisor to ensure work is coordinated effectively with others
- 1.5 Materials required for the work are identified and obtained in accordance with workplace procedures
- 1.6 Tools, equipment and testing devices needed to determine operating conditions are obtained and checked for correct operation and safety in accordance with workplace procedures
2 Determine operating conditions of air conditioning system
- 2.1 Measuring system operating parameters are implemented in accordance with job requirements and workplace safety procedures
- 2.2 Air conditioning system is checked and isolated in accordance with workplace procedures
- 2.3 Actual and specified range of operating conditions are determined from measured and calculated values as they apply to air conditioning system in accordance with workplace procedures
- 2.4 Methods for dealing with unplanned situations/events are discussed with appropriate person/s and documented
- 2.5 Unexpected situations are dealt with safely and with the approval of relevant person/s
- 2.6 Operating conditions for air conditioning system are determined without damage to apparatus, circuits, the surrounding environment or services using relevant workplace sustainable energy practices in accordance with workplace procedures
3 Complete work and report
- 3.1 Worksite and equipment are cleaned and made safe in accordance with workplace procedures
- 3.2 Operating conditions are documented, including identification of any parameter that is not within the specified range for the of air conditioning system, in accordance with workplace procedures
- 3.3 Supervisor is notified of completion of work in accordance with workplace procedures
No information
No information
Replaces
| State Code | National Code | Title | Type |
|---|---|---|---|
| S7340 | UEENEEJ104A | Establish the basic operating conditions of air conditioning systems | Unit of competency |