Unit of competency Outline

Date retreived
22/07/2026 10:45 PM AWST

Whilst all efforts are made to provide accurate and timely information from the relevant source/documentation, please be aware that the information supplied may not be the most current version. The accuracy of the detail has not been confirmed by the Department and therefore should not be relied upon without first confirming the contents.

Destroy unexploded ordnance

Destroy unexploded ordnance

Unit of competency
National Code
DEFEO702D
State Code
AVS84
TGA Status
Replaced
DTWD Status
Replaced
Current Release Number
2.00
Current Release Date
24/01/2013
State Implementation and Classification
Approved Date
Field of Education
039999 - Engineering And Related Technologies, N.e.c.
Original Release Date
Nominal Hours
0
Description
This unit covers the competency required to destroy unexploded ordnance (UXO) by detonation.Unexploded ordnance includes any authorised explosive ordnance or explosive ordnance that has failed to function as designed while in use on a licensed range. Destruction is normally carried out by explosives in the location of the unexploded ordnance.
Notes
Elements and Performance Criteria
1. Prepare for destruction
  • 1.1 Requirement for the destruction of unexploded ordnance is identified from work requests/instructions and confirmed with relevant personnel.
  • 1.2 Work health and safety (WHS) requirements including those contained in organisational procedures, are applied throughout the operation.
  • 1.3 Item/s to be destroyed and destruction method are confirmed in accordance with organisation policy and procedures.
  • 1.4 Documentation and instructions are prepared in accordance with statutory, organisation requirements.
  • 1.5 Liaison and notification of parties affected by the destruction is undertaken in accordance with organisation policy and procedures, and Range Standing Orders.
  • 1.6 Site/equipment preparation is completed in accordance with organisation policy and procedures, and Range Standing Orders.
2. Destroy unexploded ordnance
  • 2.1 Unexploded ordnance and destruction means are prepared and tested in accordance with Range Standing Orders and organisation policy.
  • 2.2 Unexploded ordnance is destroyed.
  • 2.3 Emergency and contingency procedures are applied in accordance with organisation policy and Range Standing Orders.
  • 2.4 Residue is inspected to ensure all items have been destroyed in accordance with Range Standing Orders.
3. Finalise the destruction process
  • 3.1 Site/equipment is maintained and/or refurbished in accordance with organisation policy and procedures, and Range Standing Orders.
  • 3.2 Documentation and records are maintained in accordance with statutory and organisation requirements.
The Range Statement relates to the Unit of Competency as a whole. It allows for different work environments and situations that may affect performance. Bold italicised wording in the Performance Criteria is detailed below.
Unexploded ordnance may include:
any authorised Australian Defence Force explosive ordnance that has failed to function as designed
Organisation may include:
defence organisation
enterprises that work with explosive ordnance
other government departments or instrumentalities that work with explosive ordnance
Documentation and instructions may include:
range instructions
risk analysis
Preparation may include:
calculation of safety distances including safety fuse burning times
confirmation of:
calibre of explosive ordnance to be destroyed
quantity of explosive ordnance
nature of explosive ordnance
tests including:
safety fuse
continuity tests on electric detonators
discontinuity tests on firing cables
continuity tests on firing cables
resistance tests on firing cables
The evidence guide provides advice on assessment and must be read in conjunction with the Performance Criteria, Required Skills and Knowledge, the Range Statement and the Assessment Guidelines for this Training Package.
Critical aspects for assessment and evidence required to demonstrate competency in this unit
Assessment must confirm the ability to:
comply with operational safety including the risk analysis
prepare and refurbish the destruction site or equipment
prepare instructions and documentation
destroy unexploded ordnance
apply emergency and contingency procedures
Consistency in performance
Competency should be demonstrated in a range of actual or simulated explosive ordnance destruction contexts in a safe and efficient manner.
Context of and specific resources for assessment
Context of assessment
Competency should be assessed in the workplace or in a simulated work environment, in accordance with all relevant legislation and Defence requirements.
Specific resources for assessment
Access is required to:
licensed range
unexploded ordnance to be destroyed
Method of assessment
This unit may be assessed with the following unit:
DEFEO101D Work safely with explosive ordnance.
In a public safety environment assessment is usually conducted via direct observation in a training environment or in the workplace via subject matter supervision and/or mentoring, which is typically recorded in a competency workbook.
Assessment is completed using appropriately qualified assessors who select the most appropriate method of assessment.
Assessment may occur in an operational environment or in an industry-approved simulated work environment. Forms of assessment that are typically used include:
direct observation
interviewing the candidate
journals and workplace documentation
third party reports from supervisors
written or oral questions
Replaced By
State Code National Code Title Type
AVR84 DEFEXO102 Destroy unexploded ordnance Unit of competency
No information