Unit of competency Outline

Date retreived
23/07/2026 5:17 AM AWST

Whilst all efforts are made to provide accurate and timely information from the relevant source/documentation, please be aware that the information supplied may not be the most current version. The accuracy of the detail has not been confirmed by the Department and therefore should not be relied upon without first confirming the contents.

Operate and monitor ash and dust disposal plant

Operate and monitor ash and dust disposal plant

Unit of competency
National Code
UEPOPS241B
State Code
WE315
TGA Status
Replaced
DTWD Status
Replaced
Current Release Number
1.00
Current Release Date
25/07/2012
State Implementation and Classification
Approved Date
22/07/2014
Field of Education
030717 - Plant And Machine Operations
Original Release Date
22/07/2014
Nominal Hours
36
Description
1)Scope:1.1) DescriptorThis unit deals with the skills and knowledge required to operate, inspect and monitor ash and dust disposal plants associated with a coal fired power station.
Notes
Elements and Performance Criteria
No information
RANGE STATEMENT
10) This relates to the competency standard unit as a whole providing the range of contexts and conditions to which the Performance Criteria apply. It allows for different work environments and situations that will affect performance.
Systems, plant and/or equipment may include electrical supply switchboard(s) and transformers; electrical motors; valves; dampers and actuators (electric, hydraulic, manual and pneumatic); lubricating and oil conditioning systems; supervisory, alarm, protection and control equipment; boiler ash/dust hopper and ash/dust extraction equipment; sluiceway and sluiceway equipment; ash crusher; ash and dust slurry pumps; ash, dust and dam water recovery plant; hydraulic power oil unit; dust suppression plant; dams; and transportation systems
Safety standards may include relevant sections of Occupational Health and Safety legislation, enterprise safety rules, relevant state and federal legislation, national standards for plant, Australian standards.
Information and documentation sources may include verbal or written communications; enterprise safety rules documentation; enterprise operating instructions; manufacturer’s operational and maintenance manuals; equipment and alarm manuals; dedicated computer equipment; enterprise standing instructions and plant notes; and enterprise log books.
Technical and operational indicators may include stimuli (audio, smell, touch, visual), remote or local indicators and recorders and alarms (visible and or audible).
Communications may be by means of, telephone, two way radio, pager, computer (electronic mail), operating log (written or verbal) and public address system.
Tests may include motor direction checks, stand-by plant tests, and performance tests and pump rotation checks.
Appropriate personnel to consult, give or receive direction may include supervisor/team leader or equivalent, power plant operations personnel, technical and engineering officers or equivalent, maintenance staff, contractor personnel and other production staff.
Test, fault finding and operating tools may include high voltage testers, proving dead equipment, power or hand tools.
Operating environment may be during inclement or otherwise harsh weather conditions, in wet/noisy/dusty/hot areas and during continuous operation.
Faults and abnormal operating conditions may include motor/pump/actuator /valve/dampers failure/malfunctions, control equipment failure/malfunctions, loss of electrical supply to plant and equipment, loss/low cooling air/water, low lubricating/power oil flow to auxiliary plant/equipment, clinker build ups (manual removal), excessive vibration pumps/motors, loss/low ejector water flow, loss of pump gland sealing water, high/low pit levels, blocked sluiceways and blocked/burst lines.
Generic terms are used throughout this Training Package for vocational standard shall be regarded as part of the Range Statement in which competency is demonstrated. The definition of these and other terms are given in Section 2.1 Preliminary Information and Glossaries.
EVIDENCE GUIDE
9) This provides essential advice for assessment of the competency standard unit and must be read in conjunction with the Performance Criteria and the Range Statement of the competency standard unit and the Training Package Assessment Guidelines.
The Evidence Guide forms an integral part of this competency standard unit and shall be used in conjunction with all components parts of this unit and, performed in accordance with the Assessment Guidelines of this Training Package.

Overview of Assessment
9.1)

Longitudinal competency development approaches to assessment, such as Profiling, require data to be reliably gathered in a form that can be consistently interpreted over time. This approach is best utilised in Apprenticeship programs and reduces assessment intervention. It is the Industry’s preferred model for apprenticeships. However, where summative (or final) assessment is used it is to include the application of the competency in the normal work environment or, at a minimum, the application of the competency in a realistically simulated work environment. It is recognised that, in some circumstances, assessment in part or full can occur outside the workplace. However, it must be in accord with Industry and, Regulatory policy in this regard.
Methods chosen for a particular assessment will be influenced by various factors. These include the extent of the assessment, the most effective locations for the assessment activities to take place, access to physical resources, additional safety measures that may be required and the critical nature of the competencies being assessed.
The critical safety nature of working with electricity, electrical equipment, gas or any other hazardous substance/material carries risk in deeming a person competent. Hence, sources of evidence need to be ‘rich’ in nature to minimise error in judgment.
Activities associated with normal every day work have a bearing on the decision as to how much and how detailed the data gathered will contribute to its ‘richness’. Some skills are more critical to safety and operational requirements while the same skills may be more or less frequently practised. These points are raised for the assessors to consider when choosing an assessment method and developing assessment instruments. Sample assessment instruments are included for Assessors in the Assessment Guidelines of this Training Package.

Critical aspects of evidence required to demonstrate competency in this unit
9.2)

Before the critical aspects of evidence are considered all pre-requisites shall be met.
Evidence for competence in this unit shall be considered holistically. Each Element and associated Performance Criteria shall be demonstrated on at least two occasions in accordance with the “Assessment Guidelines - UEP12”. Evidence shall also comprise:
A representative body of work performance demonstrated within the timeframes typically expected of the discipline, work function and industrial environment. In particular this shall incorporate evidence that shows a candidate is able to:
Implement Occupational Health and Safety workplace procedures and practices including the use of risk control measures as specified in the Performance Criteria and Range Statement
Apply sustainable energy principles and practices as specified in the Performance Criteria and Range Statement
Demonstrate an understanding of the Essential Knowledge and Associated Skills as described in 6) Essential Knowledge and Associated Skills of this unit
Demonstrate an appropriate level of employability skills
Conduct work observing the relevant Anti-Discrimination legislation, regulations, polices and workplace procedures
Demonstrated performance across a representative range of contexts from the prescribed items below:
Knowledge and application of relevant sections of: Occupational, health and safety legislation; Statutory legislation; Enterprise/site safety procedures; Enterprise/site emergency procedures
Preparation and planning of work
Operation of ash and dust disposal plant
Operationally testing plant
Analysing plant faults
Monitoring plant operation
Dealing with an unplanned event by drawing on Essential Knowledge and Skills to provide appropriate solutions incorporated in the holistic assessment with the above listed items.

Context of and specific resources for assessment
9.3)

This unit should be assessed as it relates to normal work practice using procedures, information and resources typical of a workplace. This should include:
OHS policy and work procedures and instructions
Suitable work environment, facilities, equipment and materials to undertake actual work as prescribed by this competency standard unit
Competency Standards should be assessed in the workplace or simulated workplace and under the normal range of workplace conditions.
Assessment of this unit will be supported with documentary evidence, by means of endorsement stating type and application of work.
In addition to the resources listed above in Context of assessment’, evidence should show competency working, in limited spaces, with different types of plant and equipment as well as different structural/construction types and method and in a variety of environments.

Method of assessment
9.4)

This unit shall be assessed by methods given in Section 1.3.00 Assessment Guidelines.
Note:
Competent performance with inherent safe working practices is expected in the Industry to which this competency standard unit applies. This requires that the specified Essential Knowledge and Associated Skills be assessed in a structured environment, which is primarily intended for learning/assessment and incorporates all necessary equipment and facilities for learners to develop and demonstrate the Essential Knowledge and Skills described in this unit.

Concurrent assessment and relationship with other units
9.5)

There are no recommended concurrent assessments with this unit, however in some cases efficiencies may be gained in terms of learning and assessment effort being concurrently managed with allied competency standard units where listed.
Nil
Replaces
State Code National Code Title Type
S5177 UEPOPS241A Operate and Monitor Ash and Dust Disposal Plant Unit of competency
Replaced By
State Code National Code Title Type
OAH31 UEPOPS241 Operate and monitor ash and dust disposal plant Unit of competency
State Code National Code Title Type
J251 UEP20112 Certificate II in ESI Generation - Operations Support Qualification