Unit of competency Outline

Date retreived
22/07/2026 9:53 AM AWST

Whilst all efforts are made to provide accurate and timely information from the relevant source/documentation, please be aware that the information supplied may not be the most current version. The accuracy of the detail has not been confirmed by the Department and therefore should not be relied upon without first confirming the contents.

Find and rectify faults in single phase motors and associated controls

Find and rectify faults in single phase motors and associated controls

Unit of competency
National Code
UEERA0044
State Code
OBX99
TGA Status
Current
DTWD Status
Approved
Current Release Number
1.00
Current Release Date
05/10/2020
State Implementation and Classification
Approved Date
12/07/2021
Field of Education
031315 - Refrigeration And Air Conditioning Mechanics
Original Release Date
12/07/2021
Nominal Hours
36
Description
This unit involves the skills and knowledge required to find and repair faults in motors and associated controls connected to single phase, 240 volt (V) supply, in refrigeration and air conditioning systems.It includes working safely, using fault-finding procedures, conducting repairs to motor and associated control components, and completing required service documentation. The skills and knowledge in this unit will be applied by refrigeration and air conditioning technicians during the commissioning and repair of refrigeration and air conditioning systems.To undertake this unit, the learner must have a current Trainee Refrigerant Handling Licence as it includes work on refrigeration and air conditioning equipment that carries the risk of a fluorocarbon refrigerant being emitted. The skills and knowledge described in this unit require a national Refrigerant Handling Licence as it includes work on refrigeration and air conditioning equipment that carries the risk of a fluorocarbon refrigerant being emitted while decanting the refrigerant or manufacturing, installing, commissioning, servicing, maintaining or decommissioning refrigeration and air conditioning equipment. The skills and knowledge described in this unit require a licence or permit to practice in the workplace where work is carried out on electrical installations which are designed to operate at voltages greater than 50 V alternating current (a.c.) or 120 V direct current (d.c.).Competency development activities in this unit are subject to regulations directly related to licensing. Where a licence or permit to practice is not held, a relevant contract of training, such as an Australian Apprenticeship, is required.Additional and/or other conditions may apply in some jurisdictions subject to regulations related to refrigeration, air conditioning and electrical work. Practice in the workplace and during training is also subject to work health and safety (WHS)/occupational health and safety (OHS) regulations.
Notes
Elements and Performance Criteria
1 Prepare to find and rectify faults in single phase motors and associated controls
  • 1.1 WHS/OHS hazards, risk control methods, relevant industry standards, codes of practice and legislation are obtained and applied in accordance with workplace procedures
  • 1.2 Work details are determined from documentation and/or supervisor to establish scope of work to be completed in accordance with workplace procedures
  • 1.3 Supervisor is consulted to ensure work is coordinated with others in accordance with workplace procedures
  • 1.4 Tools, equipment and testing devices to locate faults are obtained and checked for operational safety in accordance with workplace procedures
2 Find and repair faults in single phase motors and associated controls
  • 2.1 Need to test and measure live work is determined in accordance with workplace procedures and WHS/OHS requirements
  • 2.2 Equipment is checked and isolated in accordance with workplace procedures, regulatory requirements and WHS/OHS requirements
  • 2.3 Fault finding, using measured and calculated values of circuit and/or motor parameters, is undertaken in accordance with workplace procedures and regulatory requirements
  • 2.4 Repair work is carried out in accordance with manufacturer specifications and workplace procedures
  • 2.5 Repair work is tested in accordance with workplace procedures
  • 2.6 Apparatus is reassembled, tested and prepared for return to service in accordance with workplace procedures and regulatory requirements
  • 2.7 Unexpected situations are resolved in accordance with workplace procedures, safety guidelines and with the approval of an authorised person/supervisor
  • 2.8 Fault-finding and repair activities are completed without damage to apparatus, circuits, the surrounding environment and/or services using relevant sustainable energy practices in accordance with workplace procedures
3 Complete and report on fault-finding and repair of single phase motors and associated controls
  • 3.1 WHS/OHS work completion risk control measures are applied in accordance with workplace procedures
  • 3.2 Worksite and equipment are cleaned and made safe in accordance with workplace procedures
  • 3.3 Supervisor is notified of completion of work in accordance with workplace procedures
No information
No information
No information
State Code National Code Title Type
BMB7 UEE32225 Certificate III in Air Conditioning and Refrigeration Qualification
BFJ5 UEE32220 Certificate III in Air Conditioning and Refrigeration Qualification
BFQ1 UEE62520 Advanced Diploma of Air Conditioning and Refrigeration Engineering Qualification
BFK7 UEE51220 Diploma of Air Conditioning and Refrigeration Engineering Qualification
BMB0 UEE51225 Diploma of Air Conditioning and Refrigeration Engineering Qualification
BMB1 UEE62525 Advanced Diploma of Air Conditioning and Refrigeration Engineering Qualification
BFP9 UEE42720 Certificate IV in Air Conditioning and Refrigeration Servicing Qualification
BMB5 UEE42725 Certificate IV in Air Conditioning and Refrigeration Servicing Qualification
BMB9 UEE42825 Certificate IV in Air-conditioning Systems Energy Management and Control Qualification
BFL0 UEE42820 Certificate IV in Air-conditioning Systems Energy Management and Control Qualification
BNZ5 UEE32125 Certificate III in Appliance Service Qualification
BFL2 UEE32120 Certificate III in Appliance Service Qualification
BFO0 UEE50320 Diploma of Electrical and Refrigeration and Air Conditioning Qualification
BMB4 UEE50325 Diploma of Electrical and Refrigeration and Air Conditioning Qualification
BFM2 UEE43020 Certificate IV in Electrical Equipment and Systems Qualification
BFO5 UEE33020 Certificate III in Electrical Fitting Qualification
BFP6 UEE53020 Diploma of Electrical Systems Engineering Qualification
BFN6 UEE42920 Certificate IV in Refrigeration and Air Conditioning Systems Qualification
BMB6 UEE42925 Certificate IV in Refrigeration and Air Conditioning Systems Qualification