Unit of competency Outline

Date retreived
21/07/2026 11:18 PM AWST

Whilst all efforts are made to provide accurate and timely information from the relevant source/documentation, please be aware that the information supplied may not be the most current version. The accuracy of the detail has not been confirmed by the Department and therefore should not be relied upon without first confirming the contents.

Apply safety awareness and legal requirements for flammable refrigerants

Apply safety awareness and legal requirements for flammable refrigerants

Unit of competency
National Code
UEERA0007
State Code
OBY46
TGA Status
Current
DTWD Status
Approved
Current Release Number
1.00
Current Release Date
05/10/2020
State Implementation and Classification
Approved Date
12/07/2021
Field of Education
061301 - Occupational Health And Safety
Original Release Date
12/07/2021
Nominal Hours
9
Description
This unit involves the skills and knowledge required to apply safety awareness and legislative requirements for Class A2, A2L and A3 flammable refrigerants.It includes applying safety and relevant legislation to safely handle and store flammable refrigerants.Dangerous goods and ozone protection, work health and safety (WHS)/occupational health and safety (OHS), and synthetic greenhouse gas management legislative requirements apply to this unit.The skills and knowledgein this unit will be applied by those managing, supervising or working in or near a location that contains refrigeration or air conditioning equipment usingflammable refrigerant. These could include managers, supervisors, maintenance staff, cleaners, employees and refrigeration and air conditioning technicians
Notes
Elements and Performance Criteria
1 Prepare to work with flammable refrigerants
  • 1.1 WHS/OHS requirements, legislative requirements and workplace procedures for a given work area are identified, obtained and applied
  • 1.2 Work area access permits are obtained from relevant person/s in accordance with workplace procedures
  • 1.3 Preparations for electrical and non-electrical isolation to prevent hazards from loss of machine/system/process control are conducted in accordance with WHS/OHS and workplace procedures
  • 1.4 Tools and equipment required for work are checked for safety and correct functionality in accordance with workplace procedures and relevant industry standards
2 Apply safe working practices to flammable refrigerants
  • 2.1 WHS/OHS risk control measures, legislative requirements and workplace procedures for carrying out the work are followed
  • 2.2 Workplace procedures for dealing with accidents, fires and emergencies are followed in accordance with WHS/OHS, legislative requirements and workplace procedures
3 Follow workplace procedures for hazard identification and risk control of flammable refrigerants
  • 3.1 Hazards are identified and risk control measures implemented and monitored in consultation with relevant person/s
  • 3.2 Hazards in the work area are recognised and reported to relevant person/s in accordance with workplace procedures
  • 3.3 WHS/OHS records of incidents are completed in accordance with relevant industry standards and workplace procedures
  • 3.4 Workplace instructions and training are followed in accordance workplace procedures
No information
No information
Replaces
State Code National Code Title Type
S7404 UEENEEJ174A Apply safety awareness and legal requirements for hydrocarbon refrigerants Unit of competency
State Code National Code Title Type
BMB7 UEE32225 Certificate III in Air Conditioning and Refrigeration Qualification
BFJ5 UEE32220 Certificate III in Air Conditioning and Refrigeration Qualification
BFQ1 UEE62520 Advanced Diploma of Air Conditioning and Refrigeration Engineering Qualification
BFK7 UEE51220 Diploma of Air Conditioning and Refrigeration Engineering Qualification
BMB0 UEE51225 Diploma of Air Conditioning and Refrigeration Engineering Qualification
BMB1 UEE62525 Advanced Diploma of Air Conditioning and Refrigeration Engineering Qualification
BFP9 UEE42720 Certificate IV in Air Conditioning and Refrigeration Servicing Qualification
BMB5 UEE42725 Certificate IV in Air Conditioning and Refrigeration Servicing Qualification
BNZ5 UEE32125 Certificate III in Appliance Service Qualification
BFL2 UEE32120 Certificate III in Appliance Service Qualification
BFQ3 UEE40520 Certificate IV in Electrical - Air Conditioning Split Systems Qualification
BFO0 UEE50320 Diploma of Electrical and Refrigeration and Air Conditioning Qualification
BMB4 UEE50325 Diploma of Electrical and Refrigeration and Air Conditioning Qualification
BFO9 UEE62420 Advanced Diploma of Engineering Technology - Air Conditioning and Refrigeration Qualification
BFP3 UEE51120 Diploma of Engineering Technology - Refrigeration and Air Conditioning Qualification
AE240 UEESS00148 RAC - Design Hydrocarbon Refrigeration Systems Skill Set Skill set
AE250 UEESS00152 RAC - Install and Commission Flammable Refrigerant Air Cond. and Refrigeration Systems Skill Set Skill set
AE261 UEESS00157 RAC - Service and Repair Flammable Refrigerant Refrigeration and Air Conditioning Systems Skill Set Skill set
BFN6 UEE42920 Certificate IV in Refrigeration and Air Conditioning Systems Qualification
BMB6 UEE42925 Certificate IV in Refrigeration and Air Conditioning Systems Qualification