Unit of competency Outline

Date retreived
22/07/2026 1:09 PM AWST

Whilst all efforts are made to provide accurate and timely information from the relevant source/documentation, please be aware that the information supplied may not be the most current version. The accuracy of the detail has not been confirmed by the Department and therefore should not be relied upon without first confirming the contents.

Operate and control UV processes

Operate and control UV processes

Unit of competency
National Code
NWPTRT053
State Code
AVY06
TGA Status
Replaced
DTWD Status
Replaced
Current Release Number
1.00
Current Release Date
07/12/2015
State Implementation and Classification
Approved Date
15/04/2016
Field of Education
030907 - Water And Sanitary Engineering
Original Release Date
15/04/2016
Nominal Hours
20
Description
This unit describes the skills required to monitor and operate ultraviolet (UV) irradiation disinfection processes and to report on microbiological quality control.This unit applies to those working as operational staff with specific responsibility for ensuring that UV irradiation disinfection systems comply with organisational requirements.The skills and knowledge described in this unit must be applied within the legislative, regulatory and policy environment in which they are carried out. Organisational policies and procedures must be consulted and adhered to, particularly those relating to operating electrical equipment and working with high energy UV light sources.Those undertaking this unit would work under supervision while performing routine tasks in a range of familiar contexts.No licensing, legislative or certification requirements apply to unit at the time of publication.
Notes
Elements and Performance Criteria
1. Plan and prepare for work
  • 1.1 Determine work requirements as outlined in the standard operating procedure.
  • 1.2 Select and check equipment and tools required to meet safety requirements of task and site.
  • 1.3 Select, fit and use personal protective equipment.
2. Monitor system performance
  • 2.1 Monitor UV irradiation disinfection processes.
  • 2.2 Collect process samples and conduct standard tests.
  • 2.3 Maintain and monitor relevant WHS requirements.
3. Maintain and operate UV irradiation disinfection system
  • 3.1 Carry out routine inspections of system components.
  • 3.2 Clean and replace system components as required.
  • 3.3 Operate UV lamp sequencing.
4. Complete documentation
  • 4.1 Collect and report process data.
  • 4.2 Report observations outside defined parameters for further action.
No information
No information
Replaces
State Code National Code Title Type
D1884 NWP273A Monitor, operate and report ultraviolet irradiation disinfection systems Unit of competency
Replaced By
State Code National Code Title Type
OBN63 NWPTRT023 Monitor and operate ultraviolet processes Unit of competency