Unit of competency Outline
Date retreived
22/07/2026 6:42 AM AWST
22/07/2026 6:42 AM AWST
Whilst all efforts are made to provide accurate and timely information from the relevant source/documentation, please be aware that the information supplied may not be the most current version. The accuracy of the detail has not been confirmed by the Department and therefore should not be relied upon without first confirming the contents.
Modify - redesign electronics and communications systems
Modify - redesign electronics and communications systems
Unit of competency
National Code
UEEEC0044
UEEEC0044
State Code
OCB81
OCB81
TGA Status
Current
Current
DTWD Status
Approved
Approved
State Implementation and Classification
Approved Date
12/07/2021
Field of Education
031309 - Communications Equipment Installation And Maintenance
Original Release Date
12/07/2021
Nominal Hours
18
Description
This unit involves the skills and knowledge required to modify and redesign electronics and communications systems.It includes modification and redesign of electronics and communications system to augment existing systems for clients. It also includes safe working practices, system parameter reconfiguration, analysis to assure optimum performance, following procedures, and documenting final modifications and settings.Permits may be required for some work environments, such as confined spaces, working aloft, near live electrical apparatus and site rehabilitation.No licensing, legislative or certification requirements apply to this unit at the time of publication.
Notes
Elements and Performance Criteria
1 Prepare to modify/redesign electronics and communications system
- 1.1 Work health and safety (WHS)/occupational health and safety (OHS) requirements and workplace procedures for a given work area are obtained and applied
- 1.2 WHS/OHS risk control measures and workplace procedures in preparation for work activity are followed
- 1.3 Safety hazards that have not previously been identified are noted on job safety assessment, assessed and risk control measures implemented
- 1.4 Appropriate person/s is consulted to ensure the work is coordinated effectively with others involved on the worksite
- 1.5 System operating parameters are identified by reviewing system specifications and component technical data
- 1.6 Limitations, use and operation of the electronics and communication system to be modified are determined from original specifications, manufacturer data and industry standards
- 1.7 Extent of modification is determined from measurements, tests, inspections, system limitations and other relevant requirements
- 1.8 Specifications and instructions for the modifications are documented in accordance with job requirements and workplace procedures
- 1.9 Tools, equipment, applications and devices needed for the electronics work are obtained in accordance with workplace procedures and checked for correct operation and safety
- 1.10 Preparatory work is checked to ensure no unnecessary damage has occurred and complies with job requirements and specifications
2 Generate modification and redesign of electronics and communications system
- 2.1 WHS/OHS risk control measures and workplace procedures for carrying out the work are followed
- 2.2 Alternative modification is considered and discussed with appropriate person/s
- 2.3 Safety, functionality and economic considerations are incorporated in the proposed modification design
- 2.4 Proposed communications system modification complies with job requirements and specifications for system design alteration are documented
- 2.5 Changes in the use and operation of the communications system as a consequence of the proposed modification are included in the design documentation
- 2.6 Unplanned situations are responded to in accordance with workplace procedures, discussions with appropriate person/s and job specifications or requirements in a manner that minimises risk to personnel and equipment
- 2.7 Modification and redesign are carried out efficiently without unnecessary waste of materials or damage to electronics apparatus, the surrounding environment or services using sustainable energy principles
3 Complete design and report modification activities
- 3.1 WHS/OHS risk control work completion measures and workplace procedures are followed
- 3.2 Proposed modification is checked in accordance with workplace procedures for compliance with relevant job requirements and industry standards
- 3.3 Worksite is cleaned and made safe in accordance with workplace procedures
- 3.4 Proposed modification is submitted for appropriate organisational approval and, as required, statutory or regulatory approval
- 3.5 Approved copies of the communications system modification and redesign documents are issued and copies retained, documented and stored in records in accordance with workplace procedures
No information
No information
Replaces
| State Code | National Code | Title | Type |
|---|---|---|---|
| WC594 | UEENEEH168A | Modify - redesign of electronics and communications systems | Unit of competency |
| State Code | National Code | Title | Type |
|---|---|---|---|
| BFQ2 | UEE60220 | Advanced Diploma of Electronics and Communications Engineering | Qualification |
| BFP5 | UEE50520 | Diploma of Electronics and Communications Engineering | Qualification |