Whilst all efforts are made to provide accurate and timely information from the relevant source/documentation, please be aware that the information supplied may not be the most current version. The accuracy of the detail has not been confirmed by the Department and therefore should not be relied upon without first confirming the contents.
Utilise installed fire safety systems
Utilise installed fire safety systems
Unit of competency
National Code
PUAFIR314B
PUAFIR314B
State Code
D2998
D2998
TGA Status
Replaced
Replaced
DTWD Status
Transition (Replaced)
Transition (Replaced)
State Implementation and Classification
Approved Date
12/05/2010
Field of Education
039905 - Fire Technology
Original Release Date
12/05/2010
Nominal Hours
60
Description
This unit covers the competency required to operate and restore installed fire safety systems, and to operate building evacuation systems and emergency procedures. No licensing, legislative, regulatory or certification requirements apply to this unit at the time of publication.
Notes
Elements and Performance Criteria
1. Locate installed fire safety system/s and any associated controls and panels
- 1.1 Installed fire safety system/s are located for pre-fire planning, inspection, reports and/or onsite cues.
- 1.2 Installed fire safety system’s control/indicating panels, where applicable, are located, used and monitored in accordance with procedures, to facilitate their use in supporting firefighting operations.
2. Utilise installed fire safety system/s to maximise effectiveness of firefighting operations and occupant evacuation
- 2.1 Installed fire safety system/s are used in accordance with organisational procedures to facilitate locating the fire; to support occupant evacuation, rescue and fire suppression; and to minimise damage.
- 2.2 Any faults with the system are reported to supervisor.
3. Utilise building evacuation systems and procedures
- 3.1 Building emergency procedures and emergency response structures are identified and implemented in accordance with organisational procedures.
- 3.2 Wardens are consulted in accordance with organisational procedures.
- 3.3 Building evacuation systems are effectively operated in consultation with appropriate building facility personnel.
4. Reinstate installed fire safety system/s to service
- 4.1 System is reinstated to service after operation.
- 4.2 Any faults with the system are reported in accordance with organisational procedures.
The Range Statement relates to the Unit of Competency as a whole. It allows for different work environments and situations that may affect performance. Bold italicised wording in the Performance Criteria is detailed below.
Fire safety system/s may include:
alarms and communications, which must include:
emergency warning
emergency warning and intercommunication
fire phones
WIP phones
fire detection systems, which must include:
flame
gas
heat
smoke
fire hydrant systems, which must include:
boosters
high rise hydrant systems
pumps
ring main hydrant systems
street hydrants
fire sprinkler
fire suppression systems, which must include:
foam
gaseous (carbon dioxide, nitrogen and inert gas)
vaporising liquid
fire suppression systems, which may include:
aerosol
powder
water mist
gas detection
smoke control
Pre-fire planning may include:
hydrant location
identification of hazards onsite/nearby
location of fire safety systems
maps, floor plans
site features
structural features utilities
Using fire safety systems must include:
interrelated activities utilising the installed fire safety systems in the presence of smoke, heat or fire including:
alarm systems
communication systems
fire suppression systems
fire detection systems
hydrant systems
smoke control systems (which may include control and indicating equipment, mechanical venting, natural venting, zone/stair pressurisation)
Evacuation systems must include:
emergency control organisation as set out in Australian Standard 3745-2010 Planning for emergencies in facilities
health care emergency management structures as set out in Australian Standard AS 4083-2010 Planning for emergencies-Health care facilities
Operating evacuation systems must include compliance with:
organisational procedures
relevant standards
and may also include:
manufacturer specifications
site fire safety strategy
Fire safety system/s may include:
alarms and communications, which must include:
emergency warning
emergency warning and intercommunication
fire phones
WIP phones
fire detection systems, which must include:
flame
gas
heat
smoke
fire hydrant systems, which must include:
boosters
high rise hydrant systems
pumps
ring main hydrant systems
street hydrants
fire sprinkler
fire suppression systems, which must include:
foam
gaseous (carbon dioxide, nitrogen and inert gas)
vaporising liquid
fire suppression systems, which may include:
aerosol
powder
water mist
gas detection
smoke control
Pre-fire planning may include:
hydrant location
identification of hazards onsite/nearby
location of fire safety systems
maps, floor plans
site features
structural features utilities
Using fire safety systems must include:
interrelated activities utilising the installed fire safety systems in the presence of smoke, heat or fire including:
alarm systems
communication systems
fire suppression systems
fire detection systems
hydrant systems
smoke control systems (which may include control and indicating equipment, mechanical venting, natural venting, zone/stair pressurisation)
Evacuation systems must include:
emergency control organisation as set out in Australian Standard 3745-2010 Planning for emergencies in facilities
health care emergency management structures as set out in Australian Standard AS 4083-2010 Planning for emergencies-Health care facilities
Operating evacuation systems must include compliance with:
organisational procedures
relevant standards
and may also include:
manufacturer specifications
site fire safety strategy
The evidence guide provides advice on assessment and must be read in conjunction with the Performance Criteria, Required Skills and Knowledge, the Range Statement and the Assessment Guidelines for this Training Package.
Critical aspects for assessment and evidence required to demonstrate competency in this unit
Assessment must confirm the ability to:
locate, identify, operate and restore fire detection systems, fire suppression systems, hydrant systems, evacuation systems, smoke hazard management systems
implement organisational operating procedures relating to fire suppression
check, operate and reinstate fire safety systems under supervision.
Consistency in performance
Competency should be demonstrated over time in a range of actual or simulated workplace environments.
Context of and specific resources for assessment
Context of assessment
Competency should be assessed on-the-job or in a simulated workplace environment.
Specific resources for assessment
Access is required to:
appropriate equipment and systems
Method of assessment
In a public safety environment assessment is usually conducted via direct observation in a training environment or in the workplace via subject matter supervision and/or mentoring, which is typically recorded in a competency workbook.
Assessment is completed using appropriately qualified assessors who select the most appropriate method of assessment.
Assessment may occur in an operational environment or in an agency-approved simulated work environment. Forms of assessment that are typically used include:
direct observation
interviewing the candidate
journals and workplace documentation
third party reports from supervisors
written or oral questions
Critical aspects for assessment and evidence required to demonstrate competency in this unit
Assessment must confirm the ability to:
locate, identify, operate and restore fire detection systems, fire suppression systems, hydrant systems, evacuation systems, smoke hazard management systems
implement organisational operating procedures relating to fire suppression
check, operate and reinstate fire safety systems under supervision.
Consistency in performance
Competency should be demonstrated over time in a range of actual or simulated workplace environments.
Context of and specific resources for assessment
Context of assessment
Competency should be assessed on-the-job or in a simulated workplace environment.
Specific resources for assessment
Access is required to:
appropriate equipment and systems
Method of assessment
In a public safety environment assessment is usually conducted via direct observation in a training environment or in the workplace via subject matter supervision and/or mentoring, which is typically recorded in a competency workbook.
Assessment is completed using appropriately qualified assessors who select the most appropriate method of assessment.
Assessment may occur in an operational environment or in an agency-approved simulated work environment. Forms of assessment that are typically used include:
direct observation
interviewing the candidate
journals and workplace documentation
third party reports from supervisors
written or oral questions
Replaced By
| State Code | National Code | Title | Type |
|---|---|---|---|
| OAY77 | PUAFIR314 | Utilise installed fire safety systems | Unit of competency |
| State Code | National Code | Title | Type |
|---|---|---|---|
| C600 | PUA30601 | Certificate III in Public Safety (Firefighting and Emergency Operations) | Qualification |