Unit of competency Outline
Date retreived
22/07/2026 8:24 AM AWST
22/07/2026 8:24 AM AWST
Whilst all efforts are made to provide accurate and timely information from the relevant source/documentation, please be aware that the information supplied may not be the most current version. The accuracy of the detail has not been confirmed by the Department and therefore should not be relied upon without first confirming the contents.
Set up and shut down on-train remote control system
Set up and shut down on-train remote control system
Unit of competency
National Code
TLIB3027A
TLIB3027A
State Code
D4985
D4985
TGA Status
Replaced
Replaced
DTWD Status
Replaced
Replaced
State Implementation and Classification
Approved Date
21/03/2014
Field of Education
030717 - Plant And Machine Operations
Original Release Date
21/03/2014
Nominal Hours
30
Description
This unit involves the skills and knowledge required to set up and shut down an on-train remote control system in accordance with workplace procedures and the requirements of relevant safeworking regulations and codes of practice. It includes setting up the remote control system, setting up the lead control system, and shutting down the remote control equipment. Licensing or certification requirements are not applicable to this unit.
Notes
Elements and Performance Criteria
1Set up remote control system
- 1.1 Remote control system components are set up in accordance with operational plans and manufacturers instructions
- 1.2 Remote motive power units are placed in required operating mode
- 1.3 Communication code is entered and air and electrical systems are activated
- 1.4 Brake and traction systems are tested using approved personnel to ensure correct operation
2Set up lead control system
- 2.1 Cab console is checked, electrical systems are activated and the system self-test is confirmed
- 2.2 Communication code is entered and confirmation obtained that system has entered link mode
- 2.3 Full control is obtained and brake tests are conducted, using lead control equipment, to ensure correct braking is operational
- 2.4 Procedures to establish total control are repeated where necessary
- 2.5 Train is moved using the full range of tests to ensure operational safety and control
3Shut down remote control equipment
- 3.1 Shut-down procedures of lead and remote control equipment are followed to ensure train security and de-activation of the system
- 3.2 Equipment indicators or functions are operated to ensure the shut-down process is correct and complete
RANGE STATEMENT
The range statement relates to the unit of competency as a whole. It allows for different work environments and situations that may affect performance.
Operations conducted:
by day or night
in all relevant weather conditions
On-train remote control equipment may be:
any mechanism and operating system to allow the control of one motive power unit which is part of a train from another unit which is part of the same train
Motive power units may include all motive power units in service within Australian rail systems and may include:
diesel locomotives
electric locomotives
railcars
non-operational units
Remote control operation may be used:
within a yard for the purpose of marshalling
shunting or on running lines
on running lines
Safety and protective equipment may include:
high visibility clothing
end of train markers
gloves
sunscreen
sunglasses
safety glasses
insect repellent
safety headwear
safety footwear
portable radios/mobile phones
hand lamps
flags
safety devices
hearing protection
Information/documents may include:
workplace procedures and instructions and job specifications
induction and training materials
relevant log or record books
maintenance specifications, notices, records and requests
local instructions
equipment operation manuals
operational instructions, policies and procedures
emergency procedure manuals
two-way radio operation procedures
conditions of service, legislation and industrial agreements including workplace agreements and awards
Applicable regulations and legislation may include:
legislated rail safety requirements including acts and regulations from each applicable state and territory together with any nationally approved compliance codes and/or guidelines
relevant state/territory OH&S legislation
relevant state/territory environmental protection legislation
relevant Australian Standards
The range statement relates to the unit of competency as a whole. It allows for different work environments and situations that may affect performance.
Operations conducted:
by day or night
in all relevant weather conditions
On-train remote control equipment may be:
any mechanism and operating system to allow the control of one motive power unit which is part of a train from another unit which is part of the same train
Motive power units may include all motive power units in service within Australian rail systems and may include:
diesel locomotives
electric locomotives
railcars
non-operational units
Remote control operation may be used:
within a yard for the purpose of marshalling
shunting or on running lines
on running lines
Safety and protective equipment may include:
high visibility clothing
end of train markers
gloves
sunscreen
sunglasses
safety glasses
insect repellent
safety headwear
safety footwear
portable radios/mobile phones
hand lamps
flags
safety devices
hearing protection
Information/documents may include:
workplace procedures and instructions and job specifications
induction and training materials
relevant log or record books
maintenance specifications, notices, records and requests
local instructions
equipment operation manuals
operational instructions, policies and procedures
emergency procedure manuals
two-way radio operation procedures
conditions of service, legislation and industrial agreements including workplace agreements and awards
Applicable regulations and legislation may include:
legislated rail safety requirements including acts and regulations from each applicable state and territory together with any nationally approved compliance codes and/or guidelines
relevant state/territory OH&S legislation
relevant state/territory environmental protection legislation
relevant Australian Standards
EVIDENCE GUIDE
The evidence guide provides advice on assessment and must be read in conjunction with the performance criteria, required knowledge and skills, the range statement and the assessment guidelines for this Training Package.
Critical aspects for assessment and evidence required to demonstrate competency in this unit
The evidence required to demonstrate competency in this unit must be relevant to and satisfy all of the requirements of the elements and performance criteria of this unit and include demonstration of applying:
the underpinning knowledge and skills
relevant legislation and workplace procedures
other relevant aspects of the range statement
Assessment must include exercises which demonstrate competent performance of the following in a range of situations:
setting up remote control system in a range of configurations and/or trains
conducting post set-up tests to ensure remote control system is operating correctly
shutting down remote control system correctly
Context of and specific resources for assessment
Performance is demonstrated consistently over a period of time and in a suitable range of contexts
Resources for assessment include:
a range of relevant exercises, case studies and/or other simulated practical and knowledge assessment, and/or
access to an appropriate range of relevant operational situations in the workplace
In both real and simulated environments, access is required to:
relevant and appropriate materials and equipment, and
applicable documentation including workplace procedures, regulations, codes of practice and operation manuals
Method of assessment
Assessment of this unit must be undertaken by a registered training organisation
As a minimum, assessment of knowledge must be conducted through appropriate written/oral tests
Practical assessment must occur:
through activities in an appropriately simulated environment, and/or
in an appropriate range of situations in the workplace
The evidence guide provides advice on assessment and must be read in conjunction with the performance criteria, required knowledge and skills, the range statement and the assessment guidelines for this Training Package.
Critical aspects for assessment and evidence required to demonstrate competency in this unit
The evidence required to demonstrate competency in this unit must be relevant to and satisfy all of the requirements of the elements and performance criteria of this unit and include demonstration of applying:
the underpinning knowledge and skills
relevant legislation and workplace procedures
other relevant aspects of the range statement
Assessment must include exercises which demonstrate competent performance of the following in a range of situations:
setting up remote control system in a range of configurations and/or trains
conducting post set-up tests to ensure remote control system is operating correctly
shutting down remote control system correctly
Context of and specific resources for assessment
Performance is demonstrated consistently over a period of time and in a suitable range of contexts
Resources for assessment include:
a range of relevant exercises, case studies and/or other simulated practical and knowledge assessment, and/or
access to an appropriate range of relevant operational situations in the workplace
In both real and simulated environments, access is required to:
relevant and appropriate materials and equipment, and
applicable documentation including workplace procedures, regulations, codes of practice and operation manuals
Method of assessment
Assessment of this unit must be undertaken by a registered training organisation
As a minimum, assessment of knowledge must be conducted through appropriate written/oral tests
Practical assessment must occur:
through activities in an appropriately simulated environment, and/or
in an appropriate range of situations in the workplace
Replaced By
| State Code | National Code | Title | Type |
|---|---|---|---|
| AVK56 | TLIB3027 | Set up and shut down on-train remote control system | Unit of competency |
| State Code | National Code | Title | Type |
|---|---|---|---|
| J805 | TLI42613 | Certificate IV in Train Driving | Qualification |