Unit of competency Outline
Date retreived
22/07/2026 5:38 PM AWST
22/07/2026 5:38 PM AWST
Whilst all efforts are made to provide accurate and timely information from the relevant source/documentation, please be aware that the information supplied may not be the most current version. The accuracy of the detail has not been confirmed by the Department and therefore should not be relied upon without first confirming the contents.
Develop and connect electrical control circuits
Develop and connect electrical control circuits
Unit of competency
National Code
UEEEL0005
UEEEL0005
State Code
OBZ32
OBZ32
TGA Status
Current
Current
DTWD Status
Approved
Approved
State Implementation and Classification
Approved Date
12/07/2021
Field of Education
031313 - Electrical Fitting, Electrical Mechanics
Original Release Date
12/07/2021
Nominal Hours
72
Description
This unit involves the skills and knowledge required to develop, connect and functionally test electrical power and control circuits that perform specific control functions.It includes working safely, developing schematic diagrams and converting them to wiring diagrams, selecting and connecting contactors and control devices to perform a specific function. It also includes testing electrical control circuits and completing circuit development activities documentation.The skills and knowledge described in this unit require a licence or permit to practice in the workplace where work is carried out on electrical installations which are designed to operate at voltages greater than 50 volt (V) alternating current (a.c.) or 120 V direct current (d.c.).Competency development activities in this unit are subject to regulations directly related to licensing. Where a licence or permit to practice is not held, a relevant contract of training, such as an Australian Apprenticeship, may be required.Additional and/or other conditions may apply in some jurisdictions subject to regulations related to electrical work. Practice in the workplace and during training is also subject to work health and safety (WHS)/occupational health and safety (OHS) regulations.
Notes
Elements and Performance Criteria
1 Develop electrical control circuits
- 1.1 WHS/OHS requirements and workplace procedures for a given work area are identified obtained and applied
- 1.2 Control circuit/s requirements are determined from discussions with relevant person/s and documented in accordance with workplace procedures
- 1.3 Agreement for the control circuit/s requirement is sought from appropriate person/s and documented in accordance with workplace procedures
- 1.4 Schematic arrangement of control circuits that complies with agreed requirement is documented in accordance with workplace procedures
- 1.5 Wiring diagram of control circuits is developed from schematic diagram in accordance with workplace procedures
- 1.6 Materials needed to connect control circuit/s are obtained in accordance with workplace procedures and checked against job requirements
- 1.7 Tools, equipment and testing devices needed to connect control circuit/s are obtained in accordance with workplace procedures and checked for correct operation and safety
- 1.8 Preparatory work is checked to ensure no damage has occurred and complies with control circuit/s application requirements
2 Connect and test electrical control circuits
- 2.1 WHS/OHS risk control measures and workplace procedures for carrying out work are followed
- 2.2 Need to test or measure live electrical work is determined in accordance with WHS/OHS requirements and conducted within established safety workplace procedures
- 2.3 Circuits/machines/plant are checked and isolated as required in accordance with WHS/OHS requirements and workplace procedures
- 2.4 Control circuit component/s are connected to comply with the agreed control requirements
- 2.5 Control circuit operation is tested for functionality and in accordance with WHS/OHS requirements and workplace safety procedures
- 2.6 Non-compliant control functions are rectified
- 2.7 Unplanned situations are dealt with safely and with the approval of an authorised person in accordance with workplace procedures in a manner that minimises risk to personnel and equipment
- 2.8 Control circuits are connected, inspected and tested without unnecessary waste of materials or damage to apparatus, circuits, the surrounding environment or services using sustainable energy practice
3 Complete and document circuit development activities
- 3.1 WHS/OHS work completion risk control measures and workplace procedures are followed
- 3.2 Worksite is cleaned and made safe in accordance with workplace procedures
- 3.3 ‘As-connected’ control circuits are documented using standard drawing conventions and appropriate person/s notified in accordance with workplace procedures
No information
No information
Replaces
| State Code | National Code | Title | Type |
|---|---|---|---|
| S7326 | UEENEEG109A | Develop and connect electrical control circuits | Unit of competency |
| State Code | National Code | Title | Type |
|---|---|---|---|
| BFO0 | UEE50320 | Diploma of Electrical and Refrigeration and Air Conditioning | Qualification |
| BMB4 | UEE50325 | Diploma of Electrical and Refrigeration and Air Conditioning | Qualification |
| BFO5 | UEE33020 | Certificate III in Electrical Fitting | Qualification |
| BFN0 | UEE30820 | Certificate III in Electrotechnology Electrician | Qualification |
| BHQ1 | UEP50422 | Diploma of ESI Generation Maintenance - Electrical Electronic | Qualification |
| BHQ0 | UEP40322 | Certificate IV in ESI Generation Maintenance - Electrical Electronics | Qualification |
| BNY7 | UEE30725 | Certificate III in Switchgear and Controlgear | Qualification |
| BFJ0 | UEE30720 | Certificate III in Switchgear and Controlgear | Qualification |