Unit of competency Outline
Date retreived
23/07/2026 12:13 AM AWST
23/07/2026 12:13 AM AWST
Whilst all efforts are made to provide accurate and timely information from the relevant source/documentation, please be aware that the information supplied may not be the most current version. The accuracy of the detail has not been confirmed by the Department and therefore should not be relied upon without first confirming the contents.
Interpret architectural and engineering design specifications for structural steel detailing
Interpret architectural and engineering design specifications for structural steel detailing
Unit of competency
National Code
MSATCS301A
MSATCS301A
State Code
S7264
S7264
TGA Status
Replaced
Replaced
DTWD Status
Replaced
Replaced
State Implementation and Classification
Approved Date
19/08/2014
Field of Education
030701 - Mechanical Engineering
Original Release Date
19/08/2014
Nominal Hours
35
Description
This unit covers the skills and knowledge required to interpret design related information required for the commencement of a structural steel detailing project.
Notes
Elements and Performance Criteria
1. Obtain and check adequacy of design related information for structural steel detailing purposes
- 1.1. General arrangement drawings are obtained and interpreted including standard symbols, terms and figures used by designers
- 1.2. Adequacy of arrangement information is checked against detailer and client requirements
- 1.3. Design information is checked for any drawings or descriptions of any members, connections, components or details that lie outside the scope of standard structural practice
- 1.4. Information on suspended floors is obtained and checked
- 1.5. Column base layouts and schedules, if any, are checked
- 1.6. Specifications for grades of steel and bolt grades are obtained and checked
- 1.7. Information on standards and other design related specifications to be shown on detail drawings is checked
2. Obtain additional information where required
- 2.1. Requests for further information (RFIs) are submitted according to enterprise and project procedures
- 2.2. Adjustments to design information are made based on RFI responses and noted according to standard drawing office procedures
RANGE STATEMENT
The range statement relates to the unit of competency as a whole. It allows for different work environments and situations that may affect performance. Bold italicised wording, if used in the performance criteria, is detailed below. Essential operating conditions that may be present with training and assessment (depending on the work situation, needs of the candidate, accessibility of the item, and local industry and regional contexts) may also be included.
Legislative/regulatory requirements
All work must comply with relevant Federal and State or Territory legislative or regulatory requirements
Drawings
For the purposes of this unit drawings refers to both hard copy and software files including CAD files
Designers
Designers include architects and consulting engineers. The design information may also be provided via drawings produced by design draftspersons
Adequacy
Adequacy means that sufficient design information is provided to enable the structural steel detailer to prepare drawings that will provide all information required for fabrication and erection
Adequacy of arrangement information
Adequacy of arrangement information refers to the information normally provided on arrangement or layout drawings provided by architects and/or consulting engineers. This information includes:
building orientation
layout on a site and relationship to any other structures
primary dimensions
floor levels
beam spacing
column centres
sizes for all members, for example, beams, trusses, columns, rafters, purlins, girts, braces, crane beams
dimensions and layout drawing for any special features, for example, stairs, landings, fire escapes, and so on
Client requirements
Client requirements may include:
shop detail drawings, erection diagrams and material schedules and lists
program and format for CAD files and models
downloading by the structural steel detailer of files direct to client computers and CNC machines
size and number of hard copy drawings
specification of programs and requirements for word processed documents, spreadsheets, presentations, invoices, and so on
Suspended floors
Suspended floors may consist of reinforced concrete slab, composite slab, pre-cast planks and topping, steel plate or grating, or other specified material
Work environment
Detailing may be undertaken in a variety of work environments including commercial, home office or fabrication or construction enterprise.
Work may be performed individually on a contracting/project basis or as part of a project team and in response to combinations of paper based and electronic instructions.
The range statement relates to the unit of competency as a whole. It allows for different work environments and situations that may affect performance. Bold italicised wording, if used in the performance criteria, is detailed below. Essential operating conditions that may be present with training and assessment (depending on the work situation, needs of the candidate, accessibility of the item, and local industry and regional contexts) may also be included.
Legislative/regulatory requirements
All work must comply with relevant Federal and State or Territory legislative or regulatory requirements
Drawings
For the purposes of this unit drawings refers to both hard copy and software files including CAD files
Designers
Designers include architects and consulting engineers. The design information may also be provided via drawings produced by design draftspersons
Adequacy
Adequacy means that sufficient design information is provided to enable the structural steel detailer to prepare drawings that will provide all information required for fabrication and erection
Adequacy of arrangement information
Adequacy of arrangement information refers to the information normally provided on arrangement or layout drawings provided by architects and/or consulting engineers. This information includes:
building orientation
layout on a site and relationship to any other structures
primary dimensions
floor levels
beam spacing
column centres
sizes for all members, for example, beams, trusses, columns, rafters, purlins, girts, braces, crane beams
dimensions and layout drawing for any special features, for example, stairs, landings, fire escapes, and so on
Client requirements
Client requirements may include:
shop detail drawings, erection diagrams and material schedules and lists
program and format for CAD files and models
downloading by the structural steel detailer of files direct to client computers and CNC machines
size and number of hard copy drawings
specification of programs and requirements for word processed documents, spreadsheets, presentations, invoices, and so on
Suspended floors
Suspended floors may consist of reinforced concrete slab, composite slab, pre-cast planks and topping, steel plate or grating, or other specified material
Work environment
Detailing may be undertaken in a variety of work environments including commercial, home office or fabrication or construction enterprise.
Work may be performed individually on a contracting/project basis or as part of a project team and in response to combinations of paper based and electronic instructions.
EVIDENCE GUIDE
The Evidence Guide provides advice on assessment and must be read in conjunction with the performance criteria, required skills and knowledge, range statement and the Assessment Guidelines for the Training Package.
Overview of assessment
Critical aspects for assessment and evidence required to demonstrate competency in this unit
Demonstrates skills and knowledge to:
identify and interpret architect and engineer design specifications for structural steel constructions including constructions with suspended floors
relate design information to structural steel detailing processes including checking of adequacy of design information for the construction
establish efficient administrative arrangements for liaison with designers including arrangements for formal requests for further information
establish drawing and document control procedures
Context of and specific resources for assessment
Assessment may occur on the job or in an appropriately simulated environment
Resource implications for this unit include:
access to real or appropriately simulated detailing of structural steel constructions including provision of suitable design information
computer with suitable CAD software or manual drafting equipment and material including work areas, materials and equipment
access to steel and component manufacturers' catalogues or websites
access to relevant standards through either hard copy or internet access.
Where applicable, reasonable adjustment must be made to work environments and training situations to accommodate ethnicity, age, gender, demographics and disability.
Access must be provided to appropriate learning and/or assessment support when required. Where applicable, physical resources should include equipment modified for people with disabilities.
Method of assessment
Assessment must satisfy the endorsed assessment guidelines of the Manufacturing Training Package
Assessment methods must confirm consistency and accuracy of performance (over time and in a range of workplace relevant contexts) together with application of underpinning knowledge
Assessment methods must be by direct observation of tasks and include questioning on underpinning knowledge to ensure its correct interpretation and application
Assessment may be applied under project related conditions (real or simulated) and require evidence of process
Assessment must confirm a reasonable inference that competency is able not only to be satisfied under the particular circumstance, but is able to be transferred to other circumstances
Assessment may be in conjunction with assessment of other units of competency where structural steel detailing is involved
Guidance information for assessment
Assessment processes and techniques must be culturally appropriate and appropriate to the oracy, language and literacy capacity of the assessee and the work being performed.
The Evidence Guide provides advice on assessment and must be read in conjunction with the performance criteria, required skills and knowledge, range statement and the Assessment Guidelines for the Training Package.
Overview of assessment
Critical aspects for assessment and evidence required to demonstrate competency in this unit
Demonstrates skills and knowledge to:
identify and interpret architect and engineer design specifications for structural steel constructions including constructions with suspended floors
relate design information to structural steel detailing processes including checking of adequacy of design information for the construction
establish efficient administrative arrangements for liaison with designers including arrangements for formal requests for further information
establish drawing and document control procedures
Context of and specific resources for assessment
Assessment may occur on the job or in an appropriately simulated environment
Resource implications for this unit include:
access to real or appropriately simulated detailing of structural steel constructions including provision of suitable design information
computer with suitable CAD software or manual drafting equipment and material including work areas, materials and equipment
access to steel and component manufacturers' catalogues or websites
access to relevant standards through either hard copy or internet access.
Where applicable, reasonable adjustment must be made to work environments and training situations to accommodate ethnicity, age, gender, demographics and disability.
Access must be provided to appropriate learning and/or assessment support when required. Where applicable, physical resources should include equipment modified for people with disabilities.
Method of assessment
Assessment must satisfy the endorsed assessment guidelines of the Manufacturing Training Package
Assessment methods must confirm consistency and accuracy of performance (over time and in a range of workplace relevant contexts) together with application of underpinning knowledge
Assessment methods must be by direct observation of tasks and include questioning on underpinning knowledge to ensure its correct interpretation and application
Assessment may be applied under project related conditions (real or simulated) and require evidence of process
Assessment must confirm a reasonable inference that competency is able not only to be satisfied under the particular circumstance, but is able to be transferred to other circumstances
Assessment may be in conjunction with assessment of other units of competency where structural steel detailing is involved
Guidance information for assessment
Assessment processes and techniques must be culturally appropriate and appropriate to the oracy, language and literacy capacity of the assessee and the work being performed.
Replaced By
| State Code | National Code | Title | Type |
|---|---|---|---|
| OEX41 | MEM09223 | Interpret design specifications for structural steel detailing | Unit of competency |
| State Code | National Code | Title | Type |
|---|---|---|---|
| J367 | MEM50212 | Diploma of Engineering - Technical | Qualification |
| W240 | MEM30505 | Certificate III in Engineering - Technical | Qualification |
| J159 | MEM40412 | Certificate IV in Engineering Drafting | Qualification |
| W526 | MSA50108 | Diploma of Manufacturing Technology | Qualification |
| W522 | MSA30208 | Certificate III in Manufacturing Technology EDIT | Qualification |