Unit of competency Outline
Date retreived
22/07/2026 12:44 PM AWST
22/07/2026 12:44 PM AWST
Whilst all efforts are made to provide accurate and timely information from the relevant source/documentation, please be aware that the information supplied may not be the most current version. The accuracy of the detail has not been confirmed by the Department and therefore should not be relied upon without first confirming the contents.
Depower battery electric vehicles
Depower battery electric vehicles
Unit of competency
National Code
AURETH3001
AURETH3001
State Code
WC271
WC271
TGA Status
Replaced
Replaced
DTWD Status
Replaced
Replaced
State Implementation and Classification
Approved Date
08/08/2013
Field of Education
030505 - Automotive Electrics And Electronics
Original Release Date
08/08/2013
Nominal Hours
10
Description
This unit describes the performance outcomes required to depower battery electric vehicles (BEVs). It involves ensuring the vehicle high voltage (HV) supply system is isolated prior to commencing service and repair work.Importance is placed on the application of HV and low voltage (LV) electrical safety procedures.Licensing, legislative, regulatory or certification requirements may apply to this unit in some jurisdictions. Users are advised to check with the relevant regulatory authority.
Notes
Elements and Performance Criteria
1. Prepare for work
- 1.1. Procedures and information are sourced and work requirements are confirmed
- 1.2. Service method appropriate for the specific circumstances is selected and prepared for
2. Deactivate power control
- 2.1. Workplace health and safety (WHS) requirements and other relevant information for deactivation are identified
- 2.2. Procedure to deactivate vehicle at main control is followed to commence depowering process
3. Isolate vehicle power supply
- 3.1. HV power supply connection is located and isolated according to manufacturer instructions, taking appropriate precautions to prevent electric shock to self and others
- 3.2. LV power supply is located and disconnected according to manufacturer instructions and vehicle and workplace safety procedures
- 3.3. Vehicle is stabilised and checked for residual voltage in system
- 3.4. HV power supply connection is secured and retained to prevent re-fit by third party
- 3.5. HV power supply is identified with warning tag or sign to indicate potential hazards
Range Statement
The range statement relates to the unit of competency as a whole. It allows for different work environments and situations that may affect performance. Bold italicised wording in the performance criteria is detailed below. Essential operating conditions that may be present with training and assessment (depending on the work situation, needs of the candidate, accessibility of the item, and local industry and regional contexts) may also be included.
Procedures and information may include:
Australian standards
diagrams and sketches
engineer and manufacturer design specifications and instructions
industry codes of practice
manufacturer specifications
material safety data sheets (MSDS)
parts catalogues
verbal, written and graphical instructions issued by authorised internal and external persons
workplace recording and reporting procedures
workplace specifications and requirements
workshop manuals.
WHS requirements may include:
eliminating of hazardous materials and substances
first aid equipment
following emergency procedures
hazard and risk control
personal protective equipment (PPE), such as:
electrical safety gloves 1000V
HV insulating mats (Australian standards rated)
safety equipment
techniques for manual handling, including shifting, lifting and carrying.
Appropriate precautionsmay include:
analysing task to define risk
applying electrical safety precautions, such as:
“one hand rule”
live system warning tags and signs
depowering the vehicle
following identified OHS requirements
isolating the HV battery electrical supply
stabilising the electrical system.
The range statement relates to the unit of competency as a whole. It allows for different work environments and situations that may affect performance. Bold italicised wording in the performance criteria is detailed below. Essential operating conditions that may be present with training and assessment (depending on the work situation, needs of the candidate, accessibility of the item, and local industry and regional contexts) may also be included.
Procedures and information may include:
Australian standards
diagrams and sketches
engineer and manufacturer design specifications and instructions
industry codes of practice
manufacturer specifications
material safety data sheets (MSDS)
parts catalogues
verbal, written and graphical instructions issued by authorised internal and external persons
workplace recording and reporting procedures
workplace specifications and requirements
workshop manuals.
WHS requirements may include:
eliminating of hazardous materials and substances
first aid equipment
following emergency procedures
hazard and risk control
personal protective equipment (PPE), such as:
electrical safety gloves 1000V
HV insulating mats (Australian standards rated)
safety equipment
techniques for manual handling, including shifting, lifting and carrying.
Appropriate precautionsmay include:
analysing task to define risk
applying electrical safety precautions, such as:
“one hand rule”
live system warning tags and signs
depowering the vehicle
following identified OHS requirements
isolating the HV battery electrical supply
stabilising the electrical system.
Evidence Guide
The evidence guide provides advice on assessment and must be read in conjunction with the performance criteria, required skills and knowledge, range statement and the Assessment Guidelines for the Training Package.
Overview of assessment
Critical aspects for assessment and evidence required to demonstrate competency in this unit
The evidence required to demonstrate competency in this unit must be relevant to workplace operations and satisfy all of the requirements of the performance criteria and required skills and knowledge.
A person who demonstrates competency in this unit must be able to:
comply with WHS requirements and safe work practices
safely deactivate the vehicle and isolate HV and LV power supply
ensure the vehicle is depowered, stabilised and no residual HV power exists.
Context of, and specific resources for assessment
Competency is to be assessed in the workplace or a simulated workplace environment that accurately reflects performance in a real workplace setting.
Assessment is to occur:
using standard workplace practices and procedures
following safety requirements
applying environmental constraints
Assessment is to comply with relevant:
regulatory requirements
Australian standards
industry codes of practice
Competency is to be assessed using a BEV that uses HV and LV alternating and direct current (AC/DC) electrical systems. Where simulation is used, an operational BEV must be included in the simulation.
The following resources must be made available for the assessment of this unit:
appropriate PPE
a BEV
manufacturer specifications for the BEV
testing equipment
full range of essential tools and equipment
workplace documentation.
Method of assessment
Assessment must satisfy the endorsed Assessment Guidelines of this Training Package.
Assessment methods must confirm consistency and accuracy of performance (over time and in a range of workplace relevant contexts) together with the application of required skills and knowledge.
Assessment methods must be by direct observation of tasks and include questioning on required skills and knowledge to ensure correct interpretation and application.
Competence in this unit may be assessed in conjunction with other units which together form part of a holistic work role.
Where applicable, reasonable adjustment must be made to work environments and training situations to accommodate the needs of diverse clients.
Assessment processes and techniques must be culturally sensitive and appropriate to the language, literacy and numeracy capacity of the candidate and the work being performed.
The evidence guide provides advice on assessment and must be read in conjunction with the performance criteria, required skills and knowledge, range statement and the Assessment Guidelines for the Training Package.
Overview of assessment
Critical aspects for assessment and evidence required to demonstrate competency in this unit
The evidence required to demonstrate competency in this unit must be relevant to workplace operations and satisfy all of the requirements of the performance criteria and required skills and knowledge.
A person who demonstrates competency in this unit must be able to:
comply with WHS requirements and safe work practices
safely deactivate the vehicle and isolate HV and LV power supply
ensure the vehicle is depowered, stabilised and no residual HV power exists.
Context of, and specific resources for assessment
Competency is to be assessed in the workplace or a simulated workplace environment that accurately reflects performance in a real workplace setting.
Assessment is to occur:
using standard workplace practices and procedures
following safety requirements
applying environmental constraints
Assessment is to comply with relevant:
regulatory requirements
Australian standards
industry codes of practice
Competency is to be assessed using a BEV that uses HV and LV alternating and direct current (AC/DC) electrical systems. Where simulation is used, an operational BEV must be included in the simulation.
The following resources must be made available for the assessment of this unit:
appropriate PPE
a BEV
manufacturer specifications for the BEV
testing equipment
full range of essential tools and equipment
workplace documentation.
Method of assessment
Assessment must satisfy the endorsed Assessment Guidelines of this Training Package.
Assessment methods must confirm consistency and accuracy of performance (over time and in a range of workplace relevant contexts) together with the application of required skills and knowledge.
Assessment methods must be by direct observation of tasks and include questioning on required skills and knowledge to ensure correct interpretation and application.
Competence in this unit may be assessed in conjunction with other units which together form part of a holistic work role.
Where applicable, reasonable adjustment must be made to work environments and training situations to accommodate the needs of diverse clients.
Assessment processes and techniques must be culturally sensitive and appropriate to the language, literacy and numeracy capacity of the candidate and the work being performed.
Replaced By
| State Code | National Code | Title | Type |
|---|---|---|---|
| AXE21 | AURETH001 | Depower and reinitialise battery electric vehicles | Unit of competency |