Whilst all efforts are made to provide accurate and timely information from the relevant source/documentation, please be aware that the information supplied may not be the most current version. The accuracy of the detail has not been confirmed by the Department and therefore should not be relied upon without first confirming the contents.

Operate Hydro-Electric Generating Plant and Auxiliary Equipment

Operate Hydro-Electric Generating Plant and Auxiliary Equipment

Unit of competency
National Code
UEPOPS343A
State Code
S5229
TGA Status
Replaced
DTWD Status
Replaced
Current Release Number
1.00
Current Release Date
07/11/2006
State Implementation and Classification
Approved Date
31/05/2011
Field of Education
030717 - Plant And Machine Operations
Original Release Date
31/05/2011
Nominal Hours
30
Description
1)
This unit deals with the skills and knowledge required to operate a hydro-electric generating station. This will include both the operational and maintenance activities associated with such plant.
Notes
Elements and Performance Criteria
1 Plan and Prepare Work
  • 1.1 Occupational Health and Safety standards, statutory requirements, relevant Australian standards, codes of practice, manufacturers' specifications, environmental requirements and enterprise procedures are identified, applied and monitored throughout the work procedure.
  • 1.2 Work, plant and type of start requirements are identified from relevant personnel and documentation.
  • 1.3 Turbine running-up and loading schedules are ascertained from relevant documentation and in accordance with enterprise/site requirements.
  • 1.4 Localised plant and auxiliary equipment inspections, pre-operational tests and field preparation for service are carried out in accordance with manufacturer's and enterprise/site procedures.
  • 1.5 Plant and auxiliary equipment operational prerequisites are established in accordance with manufacturer and enterprise/site procedures.
  • 1.6 Sequence for recommissioning of plant and auxiliary equipment is determined to suit existing circumstances in accordance with enterprise/site requirements.
  • 1.7 Where appropriate, the team's and individual's roles and responsibilities within the team are identified, and where required, assist in the provision of on-the-job training.
  • 1.8 Work is planned in detail including sequencing and prioritising and considerations made, where appropriate, for the maintenance of plant security and capacity in accordance with system/site requirements.
  • 1.9 Coordination requirements, including requests for isolations where appropriate, are resolved with others involved, affected or required by the work.
2 Operate and Monitor hydro plant
  • 2.1 Plant is operated in accordance with enterprise and manufacturer operating procedures.
  • 2.2 Key indicator limits are maintained in accordance with manufacturer specifications and enterprise requirements.
  • 2.3 Auxiliary equipment is operated in accordance with enterprise and manufacturer operating procedures.
  • 2.4 Plant and auxiliary equipment is monitored and observed to detect deviations from normal operating conditions and system requirements.
  • 2.5 Plant and auxiliary equipment is operated within legislative requirements to gain maximum efficiency of energy conversion and to meet active and reactive dispatch power outputs.
  • 2.6 Corrective actions are taken to rectify any abnormalities in accordance with manufacturer's and enterprise/site procedures.
3 Test plant and auxiliary equipment operation
  • 3.1 Tests are performed in accordance with defined procedures applicable to the test.
  • 3.2 Plant and equipment is observed for correct operational response.
  • 3.3 Corrective action is taken when response is not in accordance with documentation, plant integrity or personal safety requirements.
  • 3.4 Plant and equipment is returned to required operational status on completion of test.
4 Analyse plant and auxiliary equipment faults.
  • 4.1 Causes of abnormal operating conditions are identified by analysing the technical and operational information in a logical and sequential manner.
  • 4.2 Actions necessary to rectify fault are determined.
  • 4.3 Plant integrity and personnel safety is maintained through consultation with appropriate personnel, and reference to plant, technical and operational documentation.
  • 4.4 Appropriate personnel are notified when defects are detected.
5 Complete documentation
  • 5.1 Documentation is updated, maintained and equipment problems, movements , abnormalities and status are reported and logged in accordance with enterprise/site procedures.
No information
No information
Replaces
State Code National Code Title Type
AYF83 UTPNEG227A Manage and operate hydro-electric generating plant and auxiliary equipment Unit of competency
Replaced By
State Code National Code Title Type
WE365 UEPOPS343B Operate hydro-electric generating plant and auxiliary equipment Unit of competency