Whilst all efforts are made to provide accurate and timely information from the relevant source/documentation, please be aware that the information supplied may not be the most current version. The accuracy of the detail has not been confirmed by the Department and therefore should not be relied upon without first confirming the contents.
Terminate and connect specialist cables
Terminate and connect specialist cables
Unit of competency
National Code
MEM10011B
MEM10011B
State Code
W5454
W5454
TGA Status
Replaced
Replaced
DTWD Status
Replaced
Replaced
State Implementation and Classification
Approved Date
18/06/2009
Field of Education
031313 - Electrical Fitting, Electrical Mechanics
Original Release Date
18/06/2009
Nominal Hours
27
Description
This unit covers preparing for the termination and connection of specialist cables.
Notes
Elements and Performance Criteria
1. Prepare for termination and connection of specialist cables
- 1.1. All work is undertaken safely and to workplace procedures, applicable regulations and legislative requirements.
- 1.2. Correct cables and materials are selected in accordance with job requirements.
- 1.3. Certification documentation is obtained where appropriate.
- 1.4. Preparation of work is undertaken or checked/inspected for correct locations and specifications.
2. Connect specialist cables
- 2.1. Terminations/connections are made to specifications, manufacturers' requirements and to safety and State/Territory regulations and legislative requirements.
- 2.2. Equipment and wiring are installed in a manner that does not reduce the type of protection afforded by the equipment design.
- 2.3. All cabling, connections and terminations are tested for compliance with specifications.
- 2.4. All cables, wires, conductors and connections are marked/tagged and labelled to specifications.
- 2.5. Documentation is completed correctly in accordance with relevant specifications and regulatory requirements.
RANGE STATEMENT
The range statement relates to the unit of competency as a whole. It allows for different work environments and situations that may affect performance. Bold italicised wording, if used in the performance criteria, is detailed below. Essential operating conditions that may be present with training and assessment (depending on the work situation, needs of the candidate, accessibility of the item, and local industry and regional contexts) may also be included.
Documentation
Short record of termination or test results
Tested
Continuity and resistance testing
The range statement relates to the unit of competency as a whole. It allows for different work environments and situations that may affect performance. Bold italicised wording, if used in the performance criteria, is detailed below. Essential operating conditions that may be present with training and assessment (depending on the work situation, needs of the candidate, accessibility of the item, and local industry and regional contexts) may also be included.
Documentation
Short record of termination or test results
Tested
Continuity and resistance testing
EVIDENCE GUIDE
The evidence guide provides advice on assessment and must be read in conjunction with the performance criteria, required skills and knowledge, range statement and the Assessment Guidelines for the Training Package.
Overview of assessment
A person who demonstrates competency in this unit must be able to terminate and connect specialist cables including, but not confined to: mineral insulate cables (MIMS); steel wire armoured cables (SWA); other sheathed cables such as piloted cables; composite screened cables, braided cables; and cable installations requiring specialised glands, fittings and enclosures.
Competency in this unit cannot be claimed until all prerequisites have been satisfied.
Critical aspects for assessment and evidence required to demonstrate competency in this unit
Assessors must be satisfied that the candidate can competently and consistently perform all elements of the unit as specified by the criteria, including required knowledge, and be capable of applying the competency in new and different situations and contexts.
Context of and specific resources for assessment
This unit may be assessed on the job, off the job or a combination of both on and off the job. Where assessment occurs off the job, that is the candidate is not in productive work, then an appropriate simulation must be used where the range of conditions reflects realistic workplace situations. The competencies covered by this unit would be demonstrated by an individual working alone or as part of a team. The assessment environment should not disadvantage the candidate.
This unit could be assessed in conjunction with any other units addressing the safety, quality, communication, materials handling, recording and reporting associated with terminating and connecting specialist cables or other units requiring the exercise of the skills and knowledge covered by this unit.
Method of assessment
Assessors should gather a range of evidence that is valid, sufficient, current and authentic. Evidence can be gathered through a variety of ways including direct observation, supervisor's reports, project work, samples and questioning. Questioning techniques should not require language, literacy and numeracy skills beyond those required in this unit of competency. The candidate must have access to all tools, equipment, materials and documentation required. The candidate must be permitted to refer to any relevant workplace procedures, product and manufacturing specifications, codes, standards, manuals and reference materials.
Guidance information for assessment
The evidence guide provides advice on assessment and must be read in conjunction with the performance criteria, required skills and knowledge, range statement and the Assessment Guidelines for the Training Package.
Overview of assessment
A person who demonstrates competency in this unit must be able to terminate and connect specialist cables including, but not confined to: mineral insulate cables (MIMS); steel wire armoured cables (SWA); other sheathed cables such as piloted cables; composite screened cables, braided cables; and cable installations requiring specialised glands, fittings and enclosures.
Competency in this unit cannot be claimed until all prerequisites have been satisfied.
Critical aspects for assessment and evidence required to demonstrate competency in this unit
Assessors must be satisfied that the candidate can competently and consistently perform all elements of the unit as specified by the criteria, including required knowledge, and be capable of applying the competency in new and different situations and contexts.
Context of and specific resources for assessment
This unit may be assessed on the job, off the job or a combination of both on and off the job. Where assessment occurs off the job, that is the candidate is not in productive work, then an appropriate simulation must be used where the range of conditions reflects realistic workplace situations. The competencies covered by this unit would be demonstrated by an individual working alone or as part of a team. The assessment environment should not disadvantage the candidate.
This unit could be assessed in conjunction with any other units addressing the safety, quality, communication, materials handling, recording and reporting associated with terminating and connecting specialist cables or other units requiring the exercise of the skills and knowledge covered by this unit.
Method of assessment
Assessors should gather a range of evidence that is valid, sufficient, current and authentic. Evidence can be gathered through a variety of ways including direct observation, supervisor's reports, project work, samples and questioning. Questioning techniques should not require language, literacy and numeracy skills beyond those required in this unit of competency. The candidate must have access to all tools, equipment, materials and documentation required. The candidate must be permitted to refer to any relevant workplace procedures, product and manufacturing specifications, codes, standards, manuals and reference materials.
Guidance information for assessment
Replaces
| State Code | National Code | Title | Type |
|---|---|---|---|
| M0354 | MEM10.11AA | Terminate and connect specialist cables | Unit of competency |
Replaced By
| State Code | National Code | Title | Type |
|---|---|---|---|
| OAV73 | MEM10011 | Terminate and connect specialist cables | Unit of competency |
| State Code | National Code | Title | Type |
|---|---|---|---|
| W245 | MEM40105 | Certificate IV in Engineering | Qualification |
| W247 | MEM50105 | Diploma of Engineering - Advanced Trade | Qualification |
| W236 | MEM30105 | Certificate III in Engineering - Production Systems | Qualification |
| W234 | MEM20205 | Certificate II in Engineering - Production Technology | Qualification |
| W726 | LMT31909 | Certificate III in Engineering - TCF Mechanic | Qualification |
| 3262 | 51717 | Certificate I in Metals and Engineering Studies (Pre-apprentice/School Apprentice Link) | Accredited course |