Unit of competency Outline

Date retreived
23/07/2026 12:14 AM AWST

Whilst all efforts are made to provide accurate and timely information from the relevant source/documentation, please be aware that the information supplied may not be the most current version. The accuracy of the detail has not been confirmed by the Department and therefore should not be relied upon without first confirming the contents.

Undertake radio communications site audit

Undertake radio communications site audit

Unit of competency
National Code
ICTCMP5176A
State Code
D3339
TGA Status
Replaced
DTWD Status
Replaced
Current Release Number
1.00
Current Release Date
15/06/2010
State Implementation and Classification
Approved Date
15/04/2014
Field of Education
031307 - Communications Technologies
Original Release Date
15/04/2014
Nominal Hours
40
Description
This unit describes the performance outcomes, skills and knowledge required to undertake a radio communications site audit regarding the compliance of radio frequency (RF) transmissions with relevant transmitter licence requirements.Individuals must comply with radio communications transmitter licensing requirements and operator certificates for maritime and aeronautical services and occupational health and safety (OHS) electromagnetic radiation (EMR) licensing requirements as appropriate.
Notes
Elements and Performance Criteria
1. Prepare for radio communications site audit
  • 1.1. Confirm need for site audit through appropriate triggers and arrange formal approval for site access from authorised personnel
  • 1.2. Clarify audit requirements according to relevant legislation, codes, regulations and standards including safety and security arrangements and action required to comply
  • 1.3. Clarify audit requirements with client or project originator, where appropriate, and incorporate broader audit considerations
  • 1.4. Prepare a hardcopy of site information for use as an audit validation list at site
  • 1.5. Specify staff, equipment and material resource requirements for the audit based on particular site requirements ensuring equipment has been correctly calibrated and labelled
  • 1.6. Check industry requirements for site and obtain industry licence where appropriate
2. Undertake radio communications site audit
  • 2.1. Validate specific site location according to database information
  • 2.2. Undertake audit tasks according to OHS, enterprise procedures and site specific safety requirements, and meet client or representative on site as required
  • 2.3. Conduct transmission and RFtests against approved specifications
  • 2.4. Conduct check of transmitters for licensing conditions
  • 2.5. Check transmission radio frequency against database list and obtain permission to check or alter transmission or radio frequency where appropriate
  • 2.6. Confirm site meets specific RFOHS safety requirements and licensing requirements where appropriate
  • 2.7. Confirm defined site equipment labelling comply with Australian Communications and Media Authority (ACMA) technical standards
3. Complete audit administration tasks
  • 3.1. Update or arrange for update of required records regarding audit findings and action required, including liaison with authorised personnel as agreed
  • 3.2. Monitor actions that have been recommended to ensure compliance with findings
  • 3.3. Issue enforcement actions as required
  • 3.4. Finalise audit administration and return equipment and resources according to organisational procedures
RANGE STATEMENT
The range statement relates to the unit of competency as a whole. It allows for different work environments and situations that may affect performance. Bold italicised wording, if used in the performance criteria, is detailed below. Essential operating conditions that may be present with training and assessment (depending on the work situation, needs of the candidate, accessibility of the item, and local industry and regional contexts) may also be included.
Triggers may relate to:
business plan targets
codes of practice and standards for other services and utilities:
electricity
gas
water
decisions to target certain clients
decisions to target certain sites:
communal
power level
EMR based on site power
geographical considerations
industry status (targeting of a dynamic industry)
interference complaints
investigation may be power measurement to ensure correct power
legislative requirements
licence conditions regarding the operating frequency of transmitters
occupancy transmitter still operating
power company requirements
radcom data purification
statutory authority requirements ACMA.
Authorised personnel may include:
customers
major users
site managers
site owners.
Legislation, codes, regulations and standards may include:

Australian Communications Industry Forum (ACIF) standards and codes
ACMA technical standards
ARPANSA EMR standard
assignment guidelines
Australian building codes and regulations
Australian standards
enterprise standards
environmental protection
equipment standards
fire regulations
heritage legislation
international standards
intrinsically safe lightning protection,
local government
OHS
Privacy Act
Radcoms Act
site engineering standard
spectrum planning reports
Telecoms Act
Trade Practices Act
WIs, CIs, business operating procedures (BOPs), radiocommunications assignment and licensing instruction (RALI).
Broader audit considerations may relate to:
commercial
cultural:
liaising with traditional land owners
environmental:
accessing protected areas
broken ground
location involving working over old underground workings and voids
on natural landscapes
wet conditions
working at heights or on rooftops.
Site information may include:
address of physical location
frequency output
power of transmitters
site coordinates
technical details of site
user bandwidth.
Equipment may include:
deviation meter
power meter
spectrum analyser.
Industry licence may include:
industry training for particular sites
basic OHS induction training.
Transmission and RF tests may include:
assessment of EMR levels
power measurement
RF technical measurements.
RF OHS safety requirements may relate to:
EMR levels
RF measurements
visual checks of towers.
Records may include:
completion of enterprise manual lists
computer-based documentation
electronic communication.
EVIDENCE GUIDE
The evidence guide provides advice on assessment and must be read in conjunction with the performance criteria, required skills and knowledge, range statement and the Assessment Guidelines for the Training Package.
Overview of assessment

Critical aspects for assessment and evidence required to demonstrate competency in this unit
Evidence of the ability to:
conduct radio communications site audit for at least three sites with differing licensing requirements
conduct transmission and RF tests
monitor non compliances to ensure actions completed.
Context of and specific resources for assessment
Assessment must ensure:
sites on which audits may be conducted
use of field measurement equipment currently used in industry
relevant databases, licensing requirements and other site related documentation.
Method of assessment
A range of assessment methods should be used to assess practical skills and knowledge. The following examples are appropriate for this unit:
direct observation of the candidate undertaking an audit
review of audit reports completed by the candidate for differing site types and licence requirements
oral or written questioning to assess knowledge of licensing requirement and specific technical procedures.
Guidance information for assessment
Holistic assessment with other units relevant to the industry sector, workplace and job role is recommended, for example:
ICTRFN3175A Operate and maintain radio communications technical instruments and field equipment
ICTRFN4095A Conduct radio frequency measurements
ICTRFN4174A Undertake radio communications signals monitoring.

Aboriginal people and other people from a non-English speaking background may have second language issues.

Access must be provided to appropriate learning and assessment support when required.

Assessment processes and techniques must be culturally appropriate, and appropriate to the oral communication skill level, and language and literacy capacity of the candidate and the work being performed.

In all cases where practical assessment is used it will be combined with targeted questioning to assess required knowledge. Questioning techniques should not require language, literacy and numeracy skills beyond those required in this unit of competency.

Where applicable, physical resources should include equipment modified for people with special needs.
Replaced By
State Code National Code Title Type
AWE58 ICTCMP501 Undertake radio communications site audit Unit of competency