Unit of competency Outline

Date retreived
22/07/2026 5:21 AM AWST

Whilst all efforts are made to provide accurate and timely information from the relevant source/documentation, please be aware that the information supplied may not be the most current version. The accuracy of the detail has not been confirmed by the Department and therefore should not be relied upon without first confirming the contents.

Operate self-contained breathing apparatus in an aquatic facility

Operate self-contained breathing apparatus in an aquatic facility

Unit of competency
National Code
SISCAQU417A
State Code
D6165
TGA Status
Replaced
DTWD Status
Replaced
Current Release Number
2.00
Current Release Date
28/11/2011
State Implementation and Classification
Approved Date
29/05/2014
Field of Education
061301 - Occupational Health And Safety
Original Release Date
29/05/2014
Nominal Hours
25
Description
This unit describes the performance outcomes, skills and knowledge required to operate self-contained breathing apparatus under emergency conditions in an aquatic facility.
Notes
Elements and Performance Criteria
1. Identify and evaluate emergency situations.
  • 1.1. Identify emergencies requiring the use of self-contained breathing apparatus.
  • 1.2. Communicate initial assessment of emergency to appropriate personnel according to organisational policies and procedures.
  • 1.3. Determine an appropriate response to the emergency according to relevant legislation and organisational policies and procedures.
  • 1.4. Notify appropriate personnel of emergency response according to relevant legislation and organisational policies and procedures.
2. Use self-contained breathing apparatus.
  • 2.1. Ensure self-contained breathing apparatus unit is operational according to manufacturer's specifications and organisational policies and procedures.
  • 2.2. Fit and operate the self-contained breathing apparatus unit according to relevant legislation, organisational policies and procedures and manufacturer's specifications.
  • 2.3. Control emergency situation and notify appropriate personnel according to organisational policies and procedures.
3. Complete post-emergency responsibilities.
  • 3.1. Check the self-contained breathing apparatus unit and report any faults and corrective actions required according to organisational policies and procedures.
  • 3.2. Remove, replace or repair faulty equipment and defective parts according to organisational policies and procedures and manufacturer's specifications.
  • 3.3. Clear and store the self-contained breathing apparatus unit after use, according to organisational procedures and manufacturer's specifications.
  • 3.4. Evaluate emergency procedures and recommend any changes required to improve response.
The range statement relates to the unit of competency as a whole. It allows for different work environments and situations that may affect performance. Bold italicised wording, if used in the performance criteria, is detailed below. Essential operating conditions that may be present with training and assessment (depending on the work situation, needs of the candidate, accessibility of the item, and local industry and regional contexts) may also be included.
Emergencies may include:
hazardous release of chlorine gas.
Appropriate personnel may include:
facility staff
occupational health and safety representative
emergency services.
Organisational policies and procedures may include:
occupational health and safety
emergency response
reporting
use, care, maintenance and storage of equipment.
Relevant legislation may include:
occupational health and safety
duty of care
hazardous chemicals.
Response may include:
personal response
facility response.
The evidence guide provides advice on assessment and must be read in conjunction with the performance criteria, required skills and knowledge, range statement and the Assessment Guidelines for the Training Package.
Overview of assessment

Critical aspects for assessment and evidence required to demonstrate competency in this unit
Evidence of the following is essential:
identifies emergency situations requiring the use of a self-contained breathing apparatus and determines and implements an appropriate emergency response
uses, checks, maintains and stores a self-contained breathing apparatus according to legislative, organisational and manufacturer's requirements
evaluates emergency response and makes recommendations on any actions required to improve personal and facility responses.
Context of and specific resources for assessment
Assessment must ensure:
demonstration of the use, care, maintenance and storage of a self-contained breathing apparatus on multiple occasions to demonstrate competency and consistency of performance
access to an aquatic facility where chlorine gas or chlorine is used
access to a self-contained breathing apparatus.
Method of assessment
A range of assessment methods should be used to assess practical skills and knowledge. The following examples are appropriate for this unit:
observation of the candidate using a self-contained breathing apparatus to respond to a real or simulated emergency involving the hazardous release of chlorine gas
oral or written questioning to assess knowledge of the properties of chlorine gas and its safe handling
oral or written questioning to assess knowledge of appropriate responses and procedures for dealing with emergency situations involving the hazardous release of chlorine gas
third-party reports from a supervisor detailing work performed by the candidate.
Holistic assessment with other units relevant to the industry sector, workplace and job role is recommended.
Replaces
State Code National Code Title Type
C7954 SRCAQU018A Operate self-contained breathing apparatus in an aquatic facility Unit of competency
Replaced By
State Code National Code Title Type
AVD64 SISCAQU014 Operate self-contained breathing apparatus in an aquatic facility Unit of competency
State Code National Code Title Type
J767 SIS40113 Certificate IV in Community Recreation Qualification