Unit of competency Outline

Date retreived
22/07/2026 7:26 PM AWST

Whilst all efforts are made to provide accurate and timely information from the relevant source/documentation, please be aware that the information supplied may not be the most current version. The accuracy of the detail has not been confirmed by the Department and therefore should not be relied upon without first confirming the contents.

Apply electrical theory for illuminated signage

Apply electrical theory for illuminated signage

Unit of competency
National Code
CPCCSI3012A
State Code
W9538
TGA Status
Replaced
DTWD Status
Replaced
Current Release Number
1.00
Current Release Date
19/05/2011
State Implementation and Classification
Approved Date
06/11/2009
Field of Education
031301 - Electrical Engineering
Original Release Date
06/11/2009
Nominal Hours
16
Description
This unit of competency specifies the outcomes required to apply electrical theory for signage applications.No licensing (less than 240 volts), legislative, regulatory or certification requirements apply to this unit at the time of publication.
Notes
Elements and Performance Criteria
1. Plan and prepare work.
  • 1.1. Quality assurance requirements of signage operations are recognised and adhered to.
  • 1.2. Safety (OHS) requirements in accordance with application tasks and workplace operations are recognised and adhered to.
  • 1.3. Job requirements are identified from drawings, specifications, instructions and client brief.
  • 1.4. Illuminated signage product range is assessed and selected in accordance with job requirements and relevant Australian standards.
2. Apply electrical principles for illuminated signage.
  • 2.1. Properties and availability of electricity as the energy source are identified and evaluated for specified job.
  • 2.2. Characteristics of electricity are applied to the illuminated sign activity carried out.
  • 2.3. Power consumption of illuminated signage types is evaluated and communicated to clients.
3. Clean up finished sign.
  • 3.1. Sign and surrounding surface environment/area are cleaned and waste materials removed in accordance with statutory and regulatory authority requirements.
  • 3.2. Tools and equipment, including personal protective equipment, are cleaned, maintained and stored.
RANGE STATEMENT
The range statement relates to the unit of competency as a whole. It allows for different work environments and situations that may affect performance. Bold italicised wording, if used in the performance criteria, is detailed below. Essential operating conditions that may be present with training and assessment (depending on the work situation, needs of the candidate, accessibility of the item, and local industry and regional contexts) may also be included.
Quality assurance requirements include:
attention to work specifications
Australian and international standards relevant to the sign industry
control of handling procedures
internal company quality assurance policy and risk management strategies
procedures for installing and finishing
quality of materials
use and maintenance of equipment
workplace operations and procedures.
Safety (OHS) is to be in accordance with state and territory legislation and regulations and project safety plan and may include:
emergency procedures, including extinguishing fires, organisational first aid requirements and evacuation
hazard control
hazardous materials and substances
organisational first aid
PPE prescribed under legislation, regulations and workplace policies and practices
safe operating procedures, including the conduct of operational risk assessment and treatments associated with:
concealed services (water, power and gas)
lighting
restricted access barriers
traffic control
work site visitors and the public
working at heights
working in confined spaces
working in proximity to others
use of firefighting equipment
use of machines
use of tools and equipment
workplace environmental requirements and safety.
Job requirements include:
assessment of conditions and hazards
determination of work requirements
equipment defect identification
safety plans and policies
work site inspection.
Client includes:
business owners
printers
property owners
sign manufacturers
statutory bodies.
Relevant Australian standards include:
regulatory requirements
standard drawings and details
urban design manuals.
Characteristics of electricity include:
circuits:
series
parallel
series-parallel
current
voltage
watts.
Statutory and regulatory authority requirements include:
federal, state and local authorities administering applicable Acts, regulations and codes of practice and also can pertain to:
removal of waste products
storage of chemicals.
EVIDENCE GUIDE
The evidence guide provides advice on assessment and must be read in conjunction with the performance criteria, required skills and knowledge, range statement and the Assessment Guidelines for the Training Package.
Overview of assessment
This unit of competency could be assessed in the workplace or a close simulation of the workplace environment, provided that simulated or project-based assessment techniques fully replicate construction workplace conditions, materials, activities, responsibilities and procedures.
Critical aspects for assessment and evidence required to demonstrate competency in this unit
A person who demonstrates competency in this unit must be able to provide evidence of understanding and applying:
electrical theory to a range of illuminated sign installations, including light emitting diode (LED).
Context of and specific resources for assessment
This competency is to be assessed using standard and authorised work practices, safety requirements and environmental constraints.
Assessment of essential underpinning knowledge will usually be conducted in an off-site context.
Assessment is to comply with relevant regulatory or Australian standards' requirements.
Resource implications for assessment include:
an induction procedure and requirement
realistic tasks or simulated tasks covering the mandatory task requirements
relevant specifications and work instructions
tools and equipment appropriate to applying electrical theory to illuminated signage
support materials appropriate to activity
workplace instructions relating to applying electrical theory to illuminated signage
material safety data sheets
research resources, including industry-related systems information.
Reasonable adjustments for people with disabilities must be made to assessment processes where required. This could include access to modified equipment and other physical resources, and the provision of appropriate assessment support.
Method of assessment
Assessment methods must:
satisfy the endorsed Assessment Guidelines of the Construction, Plumbing and Services Training Package
include direct observation of tasks in real or simulated work conditions, with questioning to confirm the ability to consistently identify and correctly interpret the essential underpinning knowledge required for practical application
reinforce the integration of employability skills with workplace tasks and job roles
confirm that competency is verified and able to be transferred to other circumstances and environments.
Validity and sufficiency of evidence requires that:
competency will need to be demonstrated over a period of time reflecting the scope of the role and the practical requirements of the workplace
where the assessment is part of a structured learning experience the evidence collected must relate to a number of performances assessed at different points in time and separated by further learning and practice, with a decision on competency only taken at the point when the assessor has complete confidence in the person's demonstrated ability and applied knowledge
all assessment that is part of a structured learning experience must include a combination of direct, indirect and supplementary evidence.
Assessment processes and techniques should as far as is practical take into account the language, literacy and numeracy capacity of the candidate in relation to the competency being assessed.
Supplementary evidence of competency may be obtained from relevant authenticated documentation from third parties, such as existing supervisors, team leaders or specialist training staff.
Replaced By
State Code National Code Title Type
BBA96 CPCCSG3011 Install LED technology into signs Unit of competency
State Code National Code Title Type
D410 CPC32111 Certificate III in Signage Qualification