Unit of competency Outline

Date retreived
22/07/2026 2:26 AM AWST

Whilst all efforts are made to provide accurate and timely information from the relevant source/documentation, please be aware that the information supplied may not be the most current version. The accuracy of the detail has not been confirmed by the Department and therefore should not be relied upon without first confirming the contents.

Operate a low grade fugal station

Operate a low grade fugal station

Unit of competency
National Code
FDFSUG214A
State Code
WD844
TGA Status
Replaced
DTWD Status
Replaced
Current Release Number
1.00
Current Release Date
01/05/2012
State Implementation and Classification
Approved Date
20/06/2012
Field of Education
030307 - Food Processing Technology
Original Release Date
20/06/2012
Nominal Hours
40
Description
This unit describes the outcomes required to operate the low grade fugal process from the re-heater to the magma pump and molasses cooler.
Notes
Elements and Performance Criteria
1 Prepare the low grade fugal station for operation
  • 1.1 Massecuite is conditioned to meet production requirements
  • 1.2 Services are confirmed as available and ready for operation
  • 1.3 Equipment is checked to confirm readiness for use
  • 1.4 The low grade fugal station is set up to meet production requirements
2 Operate and monitor low grade fugal station
  • 2.1 The low grade fugal station is started up and operated according to company procedures
  • 2.2 Control points are monitored to confirm performance is maintained within specification
  • 2.3 C sugar and C molasses meet specification
  • 2.4 Equipment is monitored to confirm operating condition
  • 2.5 Out-of-specification process and equipment performance is identified, rectified and/or reported according to workplace reporting procedure
  • 2.6 The workplace meets housekeeping standards
3 Handover the low grade fugal station
  • 3.1 Workplace records are maintained in accordance with workplace procedures
  • 3.2 Handover is carried out according to workplace procedure
  • 3.3 Low grade fugal station operators are aware of system and related equipment status at completion of handover
4 Shut down the low grade fugal station
  • 4.1 The appropriate shut down procedure is identified
  • 4.2 The low grade fugal station is shut down according to workplace procedures
  • 4.3 The low grade fugal station is prepared for storage in shut down mode
  • 4.4 Maintenance requirements are identified and reported according to workplace reporting procedure
The range statement relates to the unit of competency as a whole. It allows for different work environments and situations that may affect performance. Bold italicised wording, if used in the performance criteria, is detailed below. Essential operating conditions that may be present with training and assessment (depending on the work situation, needs of the candidate, accessibility of the item, and local industry and regional contexts) may also be included.
Policies and procedures
Work is carried out in accordance with company policies and procedures, licensing requirements, manufacturer's recommendations, legislative requirements, codes of practice and industrial awards and agreements.
Codes of practice
Codes of practice include the Sugar Milling Operations Industry Code of Practice.
Workplace information
Workplace information can include:
Standard Operating Procedures (SOPs)
specifications
production schedules
manufacturer's specifications.
Fugal equipment
Low grade fugal equipment may include:
low grade fugals
massecuite feed pump
distributor
fugal water and steam system
magma screw and pump
molasses pump and cooler
magma remelt system
molasses tank.
Equipment status
Confirming equipment status involves
conducting relevant pre-start checks
confirming that housekeeping standards are met
all safety guards are in place
equipment is operational.
It may also involve checking operation/calibration of measuring instrumentation.
Services
Services may include:
power
water
steam
compressed and instrumentation air.
Tests
Where tests are conducted as part of operation typical requirements are observation using a microscope and product density.
Equipment operation and monitoring
Operation and monitoring of equipment and processes typically requires the use of control panels and systems.
Process monitoring
Monitoring the process may involve the use of production data such as performance control charts.
Control points
Control points refer to those key points in a work process which must be monitored and controlled.
Teamwork
Work may require the ability to work within a team environment.
Information systems
Information systems may be print or screen based.
The evidence guide provides advice on assessment and must be read in conjunction with the performance criteria, required skills and knowledge, range statement and the Assessment Guidelines for the Training Package.
Overview of assessment
Assessment must be carried out in a manner that recognises the cultural and literacy requirements of the assessee and is appropriate to the work performed.
Critical aspects for assessment and evidence required to demonstrate competency in this unit
Evidence of ability to:
access workplace information to identify production requirements
follow start up procedure
start up and operate in both automatic and manual modes
monitor the process and equipment operation to maintain the process
control station throughput to meet factory throughput
take corrective action in response to out-of-specification results
shut down and clean fugals
report and/or record corrective action as required
shut down equipment in response to an emergency situation
demonstrate an operational shut down procedure
prepare equipment for cleaning/maintenance.
Context of and specific resources for assessment
Assessment must occur in a real or simulated workplace where the assessee has access to:
Operating procedures and related advice on equipment operation including advice on safe work practices and environmental requirements
Personal protective clothing and equipment
Product and process specifications and operating parameters
Low grade fugal station equipment
Materials including massecuite and services as required
Material Safety Data Sheets where appropriate
Housekeeping standards and procedures
Advice on environmental management issues relevant to work responsibilities
Workplace information recording systems, requirements and procedures.
They may also require
Cleaning procedures, sampling schedule and procedures and maintenance procedures and tools depending on the work requirements.
Method of assessment
Other units of competency relevant to the work role should be assessed in conjunction with this unit. This may include:
SUG202A Collect and prepare samples
SUG213A Perform standard tests on a cane sample
FDFOP2030A Operate a process control interface.
Guidance information for assessment
To ensure consistency in one's performance, competency should be demonstrated on more than one occasion over a period of time in order to cover a variety of circumstances, cases and responsibilities, and where possible, over a number of assessment activities.
Replaces
State Code National Code Title Type
S2827 SUGPLGF2A Operate a low grade fugal station Unit of competency
Replaced By
State Code National Code Title Type
OAM47 FBPSUG2014 Operate a low grade fugal station Unit of competency
State Code National Code Title Type
AC247 FDFSS00009 Fugal Operator Skill set