Unit of competency Outline
Date retreived
22/07/2026 10:55 AM AWST
22/07/2026 10:55 AM AWST
Whilst all efforts are made to provide accurate and timely information from the relevant source/documentation, please be aware that the information supplied may not be the most current version. The accuracy of the detail has not been confirmed by the Department and therefore should not be relied upon without first confirming the contents.
Suppress urban fire
Suppress urban fire
Unit of competency
National Code
PUAFIR302
PUAFIR302
State Code
OAY89
OAY89
TGA Status
Current
Current
DTWD Status
Approved
Approved
State Implementation and Classification
Approved Date
08/04/2020
Field of Education
039905 - Fire Technology
Original Release Date
08/04/2020
Nominal Hours
80
Description
This unit involves the skills and knowledge required to work as a member of a team under limited supervision when suppressing an urban fire. It includes responding to fires and determining extinguishing media, equipment and structural fire behaviour. It also includes protecting people; how to attack fires, ventilate structures, observe and react to fire conditions; undertake ancillary firefighting operations and complete operations.The unit applies to personnel required to suppress a range of different types of structure and non-structure fires where there is the potential for multiple hazards to be present.The fire sector is those sections of government departments, statutory authorities or organisations that have responsibility under jurisdictional arrangements for the delivery of firefighting and fire management services.No licensing, legislative or certification requirements apply to this unit at the time of publication.
Notes
Elements and Performance Criteria
1 Initiate response to fire
- 1.1 Fire details are received and initial response is determined, in accordance with organisational procedures
- 1.2 Firefighting personal protective clothing and equipment requirements are determined and used, based on available information
- 1.3 Changes to fire conditions are reported and acted on to determine firefighting tactics
- 1.4 Firefighting considerations are taken into account when determining tactics
2 Determine extinguishing media and equipment
- 2.1 Available static or reticulated water supplies to support firefighting operations are identified and capacity is determined
- 2.2 Selection of hose and equipment is sufficient to support firefighting operations
- 2.3 Extinguishing media are selected, in accordance with the type of fire within the area of operation
- 2.4 Breathing apparatus is used within its' safe work limitations, in accordance with manufacturers' specifications and organisational procedures
3 Determine structural fire behaviour
- 3.1 Combustion processes taking place in the structure are determined
- 3.2 Tactics for terminating combustion processes are determined
- 3.3 Presence of hazardous materials located in the fire area are identified and an appropriate plan of action is determined
4 Protect people
- 4.1 Primary and secondary searches are planned, conducted and supported, in accordance with organisational procedures
- 4.2 Appropriate priority and support is allocated to fire rescue and evacuation activities
- 4.3 Casualties are treated and/or handed into the care of medical personnel once clear of threat of fire
5 Attack fire
- 5.1 Firefighting strategies and tactics are prioritised, implemented and monitored, in accordance with organisational procedures
- 5.2 Firefighting extinguishing media are selected, in accordance with the type of fire and the actual or potential hazards identified within the area of operations
- 5.3 Fire is located and access is gained in the safest and most effective manner to minimise damage to property or the risk of injury to others or self, in accordance with organisational procedures
- 5.4 Potential fire behaviour is anticipated and action is taken to protect the safety of self and others and to achieve determined strategies
- 5.5 Breathing apparatus procedures are complied with, in accordance with organisational requirements
- 5.6 Fire is attacked using a range of extinguishing media and application techniques appropriate to type and size of fire, in accordance with manufacturers’ specifications and organisational procedures
- 5.7 Evidence of fire cause is protected and action is taken, in accordance with organisational procedures
- 5.8 Firefighting suppression activities, including extinguishing media, are used to contain spread of fire and damage to the environment and property
- 5.9 Burning and smouldering materials are identified and extinguished, in accordance with organisational requirements
- 5.10 Communication is maintained and monitored throughout firefighting operations, in accordance with organisational procedures
- 5.11 Firefighting ancillary activities are undertaken to avoid or minimise risk of environmental damage
6 Ventilate structure
- 6.1 Structures are ventilated, as required, using the most appropriate natural and mechanical ventilation techniques, in accordance with organisational procedures
- 6.2 Structures are ventilated without endangering personnel or increasing the spread of fire, in accordance with organisational procedures
7 Observe and react to fire conditions
- 7.1 Fire is continually monitored and significant changes affecting the status of the fire and effectiveness of selected firefighting strategies are reported, in accordance with organisational procedures
- 7.2 Firefighting strategies and tactics are modified and adjusted, in accordance with organisational procedures, the changing conditions at the fire or as directed
8 Undertake ancillary firefighting operations
- 8.1 Firefighting and ancillary activities undertaken at the incident ensure that the risk of injury to the public, other personnel and self is avoid or minimised
- 8.2 Salvage and overhaul activities are undertaken to support the conclusion of firefighting operations, in accordance with organisational procedures
9 Complete operations
- 9.1 Equipment is made ready for operational use, in accordance with organisational procedures
- 9.2 Damaged or missing equipment is replaced, recorded and/or reported, in accordance with organisational procedures
- 9.3 Participate in debriefing sessions
No information
No information
Replaces
| State Code | National Code | Title | Type |
|---|---|---|---|
| D2980 | PUAFIR302B | Suppress urban fire | Unit of competency |
| State Code | National Code | Title | Type |
|---|---|---|---|
| BGH6 | AHC40920 | Certificate IV in Conservation and Ecosystem Management | Qualification |
| BJR0 | AHC40924 | Certificate IV in Conservation and Ecosystem Management | Qualification |
| BEO2 | PUA30619 | Certificate III in Public Safety (Firefighting and Emergency Operations) | Qualification |
| BIT0 | PUA30622 | Certificate III in Public Safety (Firefighting and Emergency Operations) | Qualification |
| BEO4 | PUA30719 | Certificate III in Public Safety (Firefighting Operations) | Qualification |