Whilst all efforts are made to provide accurate and timely information from the relevant source/documentation, please be aware that the information supplied may not be the most current version. The accuracy of the detail has not been confirmed by the Department and therefore should not be relied upon without first confirming the contents.

Maintain battery banks and cells

Maintain battery banks and cells

Unit of competency
National Code
UTPNEG133A
State Code
S3758
TGA Status
Replaced
DTWD Status
Archived
Current Release Number
1.00
Current Release Date
21/10/1998
State Implementation and Classification
Approved Date
Field of Education
031301 - Electrical Engineering
Original Release Date
Nominal Hours
30
Description
Notes
Elements and Performance Criteria
No information
Stream: Production Plant
Field: Maintenance
Equivalencies: N/A
Types of equipment supplied by batteries may include emergency lighting systems, alarm and protection systems and process management systems
Types of batteries may include lead acid, ni-cad and hydrogen gen cells
Battery plant work area may be subject to environmental hazards, e.g. hydrogen gas and corrosive acids
Work completion details may include plant and maintenance records, job cards, check sheets and on device labelling updates.
Isolations can refer to electrical/mechanical or other associated processes
Critical aspects of evidence
The knowledge and application of relevant sections of: Occupational, health and safety legislation; Statutory legislation; Enterprise/site safety procedures; Enterprise/site emergency procedures
Attainment of electrical licence, deeming competency associated with electrical work
Preparation and planning of work
Testing techniques and procedures
Maintenance techniques and procedures
Completion of work procedures
Context of assessment
Competency Standards should be assessed in the workplace or simulated workplace and under the normal range of workplace conditions
Assessment of this unit will be supported with documentary evidence, by means of endorsement stating type and application of work
Interdependent assessment of unit
Nil
Knowledgeand Skills
A knowledge of:
Occupational health and safety standards; Relevant statutory requirements and codes of practice; Relevant Australian standards; Equipment and material required to perform the work; Isolation procedures; Battery plant and operation of its equipment; Performance and function of D.C. electrical systems; Fault finding and diagnostic techniques; Hazardous materials; Battery test procedures; Repair techniques; Regulatory procedures; Electrical principles; Circuit plan appreciation; Engineering and work shop practice; Communication principles
The ability to:
Apply occupational health and safety standards; Follow relevant statutory regulations and codes of practice; Apply relevantAustralian standards; Use plans, drawings and texts; Use hand and portable power tools; Use test and measurement instruments; Identify faults; Apply fault finding and diagnostic techniques; Repair faults; Maintain battery banks; Select materials for the job; Handle hazardous materials; Carry out work completion details; Apply data analysis techniques and tools; Communicate effectively.
Replaced By
State Code National Code Title Type
S5328 UEPOPS238A Maintain Battery Banks and Cells Unit of competency
State Code National Code Title Type