Unit of competency Outline
Date retreived
22/07/2026 6:44 PM AWST
22/07/2026 6:44 PM AWST
Whilst all efforts are made to provide accurate and timely information from the relevant source/documentation, please be aware that the information supplied may not be the most current version. The accuracy of the detail has not been confirmed by the Department and therefore should not be relied upon without first confirming the contents.
Operate fabric filter dust collection plant
Operate fabric filter dust collection plant
Unit of competency
National Code
UEPOPS113
UEPOPS113
State Code
ODY69
ODY69
TGA Status
Current
Current
DTWD Status
Approved
Approved
State Implementation and Classification
Approved Date
14/04/2023
Field of Education
030717 - Plant And Machine Operations
Original Release Date
14/04/2023
Nominal Hours
18
Description
This unit involves the skills and knowledge required to operate, inspect and monitor fabric filter dust collection plant associated with coal fired power stations.Dust collection plantis used to enhance the quality of air released from power generation processes. It consists of a blower, dust filter, a filter cleaning system and a dust receptacle or dust removal system. Competency in this unit requires the ability to plan and prepare work; operate fabric filter dust collection plant; test, analyse, monitor, inspect and report dust collection plant faults; and complete documentation. Individuals will, in general, work under supervision, in a power generation facility as an operator.Power generation plant operators are trained and authorised to isolate, prepare plant and issue permits to work.No licensing, legislative or certification requirements apply to this unit at the time of publication.
Notes
Elements and Performance Criteria
1 Plan and prepare work
- 1.1 Work health and safety (WHS)/occupational health and safety (OHS) regulations, legislative requirements, codes of practice, manufacturers’ recommendations and specifications, environmental requirements and workplace procedures are identified, applied and monitored
- 1.2 Work requirements are identified from relevant personnel and documentation in accordance with workplace procedures
- 1.3 Inspection, preoperational checks and field preparations for fabric filter dust collection service are carried out in accordance with manufacturers' recommendations and specifications, and workplace procedures
- 1.4 Fabric filter dust collection plant operational prerequisites are identified in accordance with manufacturers' recommendations and specifications, and workplace procedures
- 1.5 Sequence for recommissioning fabric filter dust collection plant is determined in accordance with workplace procedures
2 Conduct fabric filter dust collection plantoperation
- 2.1 Fabric filter dust collection plant is operated in accordance with manufacturers' recommendations and specifications, and workplace procedures
- 2.2 Fabric filter dust collection plant is monitored to detect deviations from normal operating conditions in accordance workplace procedures
- 2.3 Corrective actions are taken to rectify fabric filter dust collection plant abnormalities in accordance with workplace procedures
3 Test fabric filter dustcollectionplant operation
- 3.1 Tests are performed in accordance with workplace procedures
- 3.2 Fabric filter dust collection plant is returned to required operational status upon completion of testing in accordance with workplace procedures
4 Analyse fabric filter dust collectionplant faults
- 4.1 Causes of abnormal fabric filter dust collection plant operating conditions are identified by analysing technical and operational information in accordance with workplace procedures
- 4.2 Fabric filter dust collection plant integrity and personnel safety is maintained through consultation with relevant personnel and technical and operational documentation in accordance with workplace procedures
5 Monitor and inspect fabric filter dust collectionplant
- 5.1 Fabric filter dust collection plant to be monitored or inspected is physically identified in accordance with workplace procedures
- 5.2 Relevant personnel are notified when defects are detected in accordance with workplace procedures,
6 Complete documentation
- 6.1 Fabric filter dust collection plant problems, movements and status are reported in accordance with workplace procedures
- 6.2 Documentation is updated in accordance with workplace procedures
No information
No information
Replaces
| State Code | National Code | Title | Type |
|---|---|---|---|
| OAH17 | UEPOPS311 | Operate fabric filter dust collection plant | Unit of competency |
| State Code | National Code | Title | Type |
|---|---|---|---|
| BHQ7 | UEP30122 | Certificate III in ESI Generation | Qualification |
| BIO0 | UEP30322 | Certificate III in ESI Generation | Qualification |
| BHQ2 | UEP40122 | Certificate IV in ESI Generation | Qualification |
| BHP9 | UEP50122 | Diploma of ESI Generation | Qualification |