Unit of competency Outline

Date retreived
22/07/2026 3:30 AM AWST

Whilst all efforts are made to provide accurate and timely information from the relevant source/documentation, please be aware that the information supplied may not be the most current version. The accuracy of the detail has not been confirmed by the Department and therefore should not be relied upon without first confirming the contents.

Design dense wavelength division multiplexing installations

Design dense wavelength division multiplexing installations

Unit of competency
National Code
ICTTEN4246A
State Code
WI923
TGA Status
Replaced
DTWD Status
Replaced
Current Release Number
1.00
Current Release Date
07/02/2014
State Implementation and Classification
Approved Date
15/04/2014
Field of Education
031309 - Communications Equipment Installation And Maintenance
Original Release Date
15/04/2014
Nominal Hours
55
Description
This unit describes the performance outcomes, skills and knowledge required to design a dense wavelength division multiplexing (DWDM) system in optical networks.
Notes
Elements and Performance Criteria
1. Obtain access to work site safely and with authority from site owner
  • 1.1 Obtain and review DWDM installation brief
  • 1.2 Determine site access requirements
  • 1.3 Notify parties if necessary to arrange access to site to discuss DWDM installation requirements
  • 1.4 Assess site-specific safety requirements and enterprise work health and safety (WHS) processes and procedures
2. Prepare to install design DWDM units
  • 2.1 Survey location for DWDM installation and scope the installation parameters
  • 2.2 Identify suitable location for DWDM equipment racks
  • 2.3 Determine number and location of shelves and cards in the racks
  • 2.4 Determine capacity of the optical distribution frames (ODFs), patching and network management system (NMS) connections for the installation
  • 2.5 Determine power feed options
3. Design DWDM units and associated cabling
  • 3.1 Design DWDM racks, including locations and layout
  • 3.2 Examine standards, practices and requirements for designing DWDM systems
  • 3.3 Design DWDM shelf and card positions from customer and manufacturer documents
  • 3.4 Design supporting patch panel and jumpering schemes
  • 3.5 Include appropriate ancillary equipment and connections in design specifications
  • 3.6 Prepare detailed design drawings for racks, shelves and cards from manufacturer and carrier documents
  • 3.7 Prepare detailed design drawings for patching, jumpering and power feeds from manufacturer and carrier documents
4. Review design for compliance with standards and legislation
  • 4.1 Confirm that DWDM installation design meets the brief
  • 4.2 Review installation design to ensure compliance with requirements of federal, state and local regulations, relevant legislation, codes and standards
The range statement relates to the unit of competency as a whole. It allows for different work environments and situations that may affect performance. Bold italicised wording, if used in the performance criteria, is detailed below. Essential operating conditions that may be present with training and assessment (depending on the work situation, needs of the candidate, accessibility of the item, and local industry and regional contexts) may also be included.

Site may include:
optical add drop multiplexer (OADM) site
terminal site.
Equipment racks may include:
19 inch type
23 inch type
535 mm (ETSI rack) type.
Power feed options may include:
battery options
earthing requirements
primary power sources
rectifier and transformer requirements
separations form other services.
Patch panels may include:
rack mounted
wall mounted.
Ancillary equipment and connections may include:
air filter
alarm connections
C/L band splitter tray
cooling fan assembly
coupler tray
craft terminal
data communications connections
equaliser tray
ethernet hub
fibre management trays
optical attenuators
optical fibre patch cords
optical multiplexer
optical service channel tray
telemetry connections
variable optical attenuators.
Legislation may include:
AS Communications Cabling Manual (CCM) Volume 1
AS/NZS - relevant codes
Australian building codes and regulations
cabling security codes and regulations
Comms Alliance (CA) standards and codes
relevant international standards where they are enforced
technical standards AS/ACIF S008:2006 and AS/ACIF S009:2006
Telecommunications Act and code of practice
WHS Acts and relevant codes and standards.
The evidence guide provides advice on assessment and must be read in conjunction with the performance criteria, required skills and knowledge, range statement and the Assessment Guidelines for the Training Package.

Overview of assessment

Critical aspects for assessment and evidence required to demonstrate competency in this unit
Evidence of the ability to:

design a DWDM installation and associated cabling according to installation brief and installation site conditions
design DWDM system power and ground connections
complete and confirm installation design report.
Context of and specific resources for assessment
Assessment must ensure:

suitable site for DWDM equipment installation
access to tools and equipment required for installation
a range of optical fibres to suit the installation.
Method of assessment
A range of assessment methods should be used to assess practical skills and knowledge. The following examples are appropriate for this unit:

direct observation of the candidate preparing designs for DWDM systems
review of DWDM designs prepared by the candidate
oral or written questioning of the candidate to assess knowledge of DWDM design practices.
Guidance information for assessment
Holistic assessment with other units relevant to the industry sector, workplace and job role is recommended, for example:

ICTBWN3088B Install optical fibre splitters in fibre distribution hubs
ICTTEN3056A Install telecommunications network equipment.

Aboriginal people and other people from a non-English speaking background may have second language issues.

Access must be provided to appropriate learning and assessment support when required.
Assessment processes and techniques must be culturally appropriate, and appropriate to the oral communication skill level, and language and literacy capacity of the candidate and the work being performed.

In all cases where practical assessment is used it will be combined with targeted questioning to assess required knowledge. Questioning techniques should not require language, literacy and numeracy skills beyond those required in this unit of competency.

Where applicable, physical resources should include equipment modified for people with special needs.
Replaced By
State Code National Code Title Type
AWD20 ICTTEN431 Design a dense wavelength division multiplexing system Unit of competency
State Code National Code Title Type
J821 ICT40713 Certificate IV in Telecommunications Network Design Qualification