Whilst all efforts are made to provide accurate and timely information from the relevant source/documentation, please be aware that the information supplied may not be the most current version. The accuracy of the detail has not been confirmed by the Department and therefore should not be relied upon without first confirming the contents.
Perform non-standard calibrations
Perform non-standard calibrations
Unit of competency
National Code
MSL905001A
MSL905001A
State Code
WA656
WA656
TGA Status
Replaced
Replaced
DTWD Status
Replaced
Replaced
State Implementation and Classification
Approved Date
04/08/2010
Field of Education
019909 - Laboratory Technology
Original Release Date
04/08/2010
Nominal Hours
60
Description
This unit of competency covers the ability to recognise non-conforming calibration work, to research and select the most appropriate test method or calibration procedure for a given measurement request and then conduct the calibration. It also covers the ability to modify and revise existing procedures or substitute alternative instruments and measurement standards, when necessary.
Notes
Elements and Performance Criteria
1. Select the appropriate calibration procedure
- 1.1. Identify non-conforming calibration tasks and requests and analyse their significance
- 1.2. Review the authorised procedure and establish whether it is appropriate for the test, if required
- 1.3. Research an alternative or adapt an existing procedure to satisfy the test specification requirements, if required
- 1.4. Confirm that available resources meet all the requirements of the calibration procedure
- 1.5. Obtain authorisation prior to substituting equipment, changing or deviating from the specified procedure
- 1.6. Document and validate any authorised changes or deviations in accordance with enterprise procedures
2. Prepare items for calibration
- 2.1. Identify hazards and use the appropriate personal protective equipment, safety equipment and procedures
- 2.2. Assemble and set up reference standards and associated equipment prior to testing
- 2.3. Verify performance of reference standards and measuring equipment prior to use and adjust or calibrate as necessary
- 2.4. Identify and minimise potential sources of measurement error
3. Perform calibration
- 3.1. Perform individual tests and document each step in the calibration procedure to ensure repeatability of measurement
- 3.2. Critically analyse readings to confirm they are the result of a valid measurement and record data as required (as-found or before adjustment)
- 3.3. Adjust device under test to bring readings within tolerance and record results (as-left or after adjustment) if required
- 3.4. Analyse resulting test data to detect trends or inconsistencies that would significantly affect the accuracy or validity of test results
- 3.5. Seek appropriate advice when result interpretation is outside authorised scope of approval
4. Document results
- 4.1. Document compliance/non-compliance with requirements of test and/or specifications
- 4.2. Estimate and document uncertainty of measurement in accordance with enterprise procedures, if required
- 4.3. Record the results of each test/calibration accurately, unambiguously and objectively
- 4.4. Ensure confidentiality of enterprise information
5. Finalise calibration
- 5.1. Prepare and issue a final report for the job/item detailing testing carried out, statement of compliance and all other required information
- 5.2. Report any non-compliance and verify next course of action with supervisor
- 5.3. Attach calibration labels, equipment stickers, quality control tags and tamper resistant seals as required in enterprise procedures
- 5.4. Report all changes and deviations that may have a significant influence on the test
- 5.5. Store test equipment/measurement standards and results in accordance with enterprise procedures
RANGE STATEMENT
The range statement relates to the unit of competency as a whole. It allows for different work environments and situations that may affect performance. Bold italicised wording, if used in the performance criteria, is detailed below. Essential operating conditions that may be present with training and assessment (depending on the work situation, needs of the candidate, accessibility of the item, and local industry and regional contexts) may also be included.
Codes of practice
Where reference is made to industry codes of practice, and/or Australian/international standards, it is expected the latest version will be used
Standards, codes, procedures and/or enterprise requirements
Standards, codes, procedures and/or enterprise requirements may include:
Australian and international standards, such as:
AS ISO 17025-2005 General requirements for the competence of testing and calibration laboratories
AS/NZS ISO 9001:2008 Quality management systems - Requirements
AS/NZS ISO 10005:2006 Quality management systems - Guidelines for quality plans
AS/NZS ISO 10012:2004 Quality assurance requirements for measurement equipment
ISO 5725 Accuracy (trueness and precision) of measurement methods and results
ISO/IEC Guide 98-3:2008 Uncertainty of measurement - Part 3 Guide to the expression of uncertainty in measurement (GUM)
Eurachem/CITAC Guide CG4 Quantifying uncertainty in analytical measurement
material safety data sheets (MSDS)
enterprise recording and reporting procedures and standard operating procedures (SOPs)
quality manuals, equipment and operating/technical manuals
test methods and calibration procedures (validated and authorised)
test methods and calibration procedures published by international, national or regional standards, reputable technical organisations, scientific texts or journals and equipment manufacturers
incident and accident/injury reports
schematics, workflows, laboratory layouts and production and laboratory schedules
Non-standard calibrations
Non-standard calibrations involve detecting and dealing with non-conforming work associated with the testing and/or calibrating of equipment, such as:
common test equipment, such as anemometers, balances, barometers, calipers, environmental chambers, hygrometers, manometers, masses, micrometers, pressure equipment, spectrophotometers, tape measures, rules, temperature (digital) indicating systems, thermometers, thermocouples, timing devices, vibration analysis equipment and weighing instruments
electrical reference standards, such as air-lines, analogue meters, attenuators, bridges-manual balance, capacitors, DC voltage references, digital instruments (calibrators, DMMs, electronic transfer standards), inductors, instrument and ratio transformers, instrument transformer test sets, potentiometers, resistors, radio frequency (RF) power meters, RF thermistor mounts and thermal converters, shunts, time interval and frequency standards, transfer standards AC-DC, voltage dividers, volt ratio boxes and watt-hour references
working standards, instruments and testing equipment, such as electromagnetic compatibility (EMC) test equipment, field strength meters, flammability test equipment, gauges/test fingers/test pins, hipot testers, impact hammers, impulse testers, instrument calibrators, network analysers, signal generators and spectrum and harmonic analysers
Hazards
Hazards may include:
electric shock
disturbance or interruption of services
manual handling of heavy equipment boxes
sources of electromagnetic radiation (lasers, RF generators/transmitters)
fluids under pressure
heat sources, such as ovens
Safety procedures
Safety procedures may include:
use of personal protective equipment, such as hearing protection, gloves, safety glasses and coveralls
ensuring access to service shut-off points
handling and storing hazardous materials and equipment in accordance with labels, MSDS, manufacturer's instructions and enterprise procedures and regulations
regular cleaning of equipment and work areas
Communication
Communication may be with:
supervisors and managers (laboratory, quality and customer service)
peers and other laboratory or relevant technical personnel
clients and end users of equipment
external auditors, or accreditation agency for example, National Association of Testing Authorities (NATA)
equipment manufacturers and suppliers of spare parts
Working environment
The working environment will have a controlled environment but could be a:
purpose-built designed facility
mobile facility in the field
Occupational health and safety (OHS) and environmental management requirements
OHS and environmental management requirements:
all operations must comply with enterprise OHS and environmental management requirements, which may be imposed through state/territory or federal legislation - these requirements must not be compromised at any time
all operations assume the potentially hazardous nature of samples and require standard precautions to be applied
where relevant, users should access and apply current industry understanding of infection control issued by the National Health and Medical Research Council (NHMRC) and State and Territory Departments of Health
The range statement relates to the unit of competency as a whole. It allows for different work environments and situations that may affect performance. Bold italicised wording, if used in the performance criteria, is detailed below. Essential operating conditions that may be present with training and assessment (depending on the work situation, needs of the candidate, accessibility of the item, and local industry and regional contexts) may also be included.
Codes of practice
Where reference is made to industry codes of practice, and/or Australian/international standards, it is expected the latest version will be used
Standards, codes, procedures and/or enterprise requirements
Standards, codes, procedures and/or enterprise requirements may include:
Australian and international standards, such as:
AS ISO 17025-2005 General requirements for the competence of testing and calibration laboratories
AS/NZS ISO 9001:2008 Quality management systems - Requirements
AS/NZS ISO 10005:2006 Quality management systems - Guidelines for quality plans
AS/NZS ISO 10012:2004 Quality assurance requirements for measurement equipment
ISO 5725 Accuracy (trueness and precision) of measurement methods and results
ISO/IEC Guide 98-3:2008 Uncertainty of measurement - Part 3 Guide to the expression of uncertainty in measurement (GUM)
Eurachem/CITAC Guide CG4 Quantifying uncertainty in analytical measurement
material safety data sheets (MSDS)
enterprise recording and reporting procedures and standard operating procedures (SOPs)
quality manuals, equipment and operating/technical manuals
test methods and calibration procedures (validated and authorised)
test methods and calibration procedures published by international, national or regional standards, reputable technical organisations, scientific texts or journals and equipment manufacturers
incident and accident/injury reports
schematics, workflows, laboratory layouts and production and laboratory schedules
Non-standard calibrations
Non-standard calibrations involve detecting and dealing with non-conforming work associated with the testing and/or calibrating of equipment, such as:
common test equipment, such as anemometers, balances, barometers, calipers, environmental chambers, hygrometers, manometers, masses, micrometers, pressure equipment, spectrophotometers, tape measures, rules, temperature (digital) indicating systems, thermometers, thermocouples, timing devices, vibration analysis equipment and weighing instruments
electrical reference standards, such as air-lines, analogue meters, attenuators, bridges-manual balance, capacitors, DC voltage references, digital instruments (calibrators, DMMs, electronic transfer standards), inductors, instrument and ratio transformers, instrument transformer test sets, potentiometers, resistors, radio frequency (RF) power meters, RF thermistor mounts and thermal converters, shunts, time interval and frequency standards, transfer standards AC-DC, voltage dividers, volt ratio boxes and watt-hour references
working standards, instruments and testing equipment, such as electromagnetic compatibility (EMC) test equipment, field strength meters, flammability test equipment, gauges/test fingers/test pins, hipot testers, impact hammers, impulse testers, instrument calibrators, network analysers, signal generators and spectrum and harmonic analysers
Hazards
Hazards may include:
electric shock
disturbance or interruption of services
manual handling of heavy equipment boxes
sources of electromagnetic radiation (lasers, RF generators/transmitters)
fluids under pressure
heat sources, such as ovens
Safety procedures
Safety procedures may include:
use of personal protective equipment, such as hearing protection, gloves, safety glasses and coveralls
ensuring access to service shut-off points
handling and storing hazardous materials and equipment in accordance with labels, MSDS, manufacturer's instructions and enterprise procedures and regulations
regular cleaning of equipment and work areas
Communication
Communication may be with:
supervisors and managers (laboratory, quality and customer service)
peers and other laboratory or relevant technical personnel
clients and end users of equipment
external auditors, or accreditation agency for example, National Association of Testing Authorities (NATA)
equipment manufacturers and suppliers of spare parts
Working environment
The working environment will have a controlled environment but could be a:
purpose-built designed facility
mobile facility in the field
Occupational health and safety (OHS) and environmental management requirements
OHS and environmental management requirements:
all operations must comply with enterprise OHS and environmental management requirements, which may be imposed through state/territory or federal legislation - these requirements must not be compromised at any time
all operations assume the potentially hazardous nature of samples and require standard precautions to be applied
where relevant, users should access and apply current industry understanding of infection control issued by the National Health and Medical Research Council (NHMRC) and State and Territory Departments of Health
EVIDENCE GUIDE
The Evidence Guide provides advice on assessment and must be read in conjunction with the performance criteria, required skills and knowledge, range statement and the Assessment Guidelines for the Training Package.
Overview of assessment
Critical aspects for assessment and evidence required to demonstrate competency in this unit
Assessors should ensure that candidates can:
identify non-conforming calibration tasks and requests and assess their significance
research current, alternative calibration methods and equipment for a given request
quantify the potential or actual impact of a wide range of test/environmental/equipment influences on data quality
explain complex calibration procedures to clients and clarify requirements and deviations
maintain very close attention to procedures, accuracy and precision of measurement to ensure integrity of test/calibration results
critically examine each calibration step to ensure repeatability and validity of data
prepare test/calibration documentation that is accurate and complies with requirements
operate a wide range of equipment correctly and safely
apply all relevant enterprise procedures to ensure the quality and integrity of the services or data they provide
recognise opportunities for improvements to procedures.
Context of and specific resources for assessment
This unit of competency is to be assessed in the workplace or simulated workplace environment.
This unit of competency may be assessed with:
MSL925001A Analyse data and report results
MSL925002A Analyse measurements and estimate uncertainties.
Resources may include:
specialised calibration/test equipment, reference standards and materials and laboratory facilities
access to a library of calibration methods, procedures and equipment specifications
enterprise quality manual and procedures.
Method of assessment
The following assessment methods are suggested:
review of calibration results, uncertainty calculations and documentation completed by the candidate
feedback from supervisors and/or customers regarding quality of calibration services provided by the candidate
observation of the candidate conducting non-standard calibrations
oral or written questioning to check underpinning knowledge of non-standard calibration procedures.
In all cases, practical assessment should be supported by questions to assess underpinning knowledge and those aspects of competency which are difficult to assess directly.
Where applicable, reasonable adjustment must be made to work environments and training situations to accommodate ethnicity, age, gender, demographics and disability.
Access must be provided to appropriate learning and/or assessment support when required.
The language, literacy and numeracy demands of assessment should not be greater than those required to undertake the unit of competency in a work like environment.
This competency in practice
Industry representatives have provided the case studies below to illustrate the practical application of this unit of competency and to show its relevance in a workplace setting.
Background
Calibration technicians/specialists have the skills and knowledge to operate, maintain and calibrate a wide variety of complex test equipment and measuring instruments with limited guidance. They must remain abreast of technical and equipment advances, interpret complex technical information accurately and liaise with clients to clarify their needs. They must demonstrate high levels of initiative and concentration when performing technically demanding measurements, providing solutions for non-conforming work and when adjusting or repairing complex instruments. The calibration specialist's workload can be routine and repetitive. A perpetual back-log of work and the constant need to reduce turn-around-time to meet client demands coupled with enterprise productivity goals can induce stress and mental fatigue if not carefully managed. However, it is essential that personnel are able to perform tests and associated work tasks without undue pressure that might influence technical judgement if 'integrity of measurement' is to be retained.
Calibration (1)
A client has delivered a new model vibration transducer to the laboratory and would like a full test report on the item. A calibration technician assesses the job. They conclude that because the item is new to the industry, the laboratory will probably not have a documented calibration procedure. A quick ring around the company's other laboratories confirms that a procedure has not been written yet. They analyse the item's technical specifications and realise that although a generic procedure will suffice for most of the tests, it will have to be modified.
The technician reports these concerns to the supervisor who confirms that the client wants to know if the item meets the manufacturer's specifications. Approval is given to the technician to modify a previous procedure. The revised procedure is shown to the supervisor who checks each step and confirms the test is technically justified and all uncertainties have been calculated and documented.
The technician sets up the reference standards, confirms they are fully operational and within specification and begin the test. Each stage of the test is carefully monitored to ensure the data is correct and valid. On completion, another technician conducts the test and the data is compared. The supervisor is confident the test and data are valid and a report is generated, including a method validation summary for the laboratory's records.
Calibration (2)
A calibration technician is scheduled to calibrate a client's signal generator in accordance with the manufacturer's procedure. The technician reads the procedure and assembles all the required reference standards but notices the laboratory's reference frequency counter is not available because it has been sent away for calibration. The technician needs to substitute another instrument and so scans the other workbenches. They decide on a particular model and refer to the instrument's technical specifications to confirm that it has all the required ranges and is accurate enough. Convinced this item will do the job, the technician seeks and gains approval from the supervisor. There is no need to consult with the customer because the substitution will have no negative influence on the results. The technician completes the calibration in accordance with the procedure. In the final report, they document the details of the replacement equipment used in the test to ensure the repeatability of measurements and to comply with statutory regulations.
The Evidence Guide provides advice on assessment and must be read in conjunction with the performance criteria, required skills and knowledge, range statement and the Assessment Guidelines for the Training Package.
Overview of assessment
Critical aspects for assessment and evidence required to demonstrate competency in this unit
Assessors should ensure that candidates can:
identify non-conforming calibration tasks and requests and assess their significance
research current, alternative calibration methods and equipment for a given request
quantify the potential or actual impact of a wide range of test/environmental/equipment influences on data quality
explain complex calibration procedures to clients and clarify requirements and deviations
maintain very close attention to procedures, accuracy and precision of measurement to ensure integrity of test/calibration results
critically examine each calibration step to ensure repeatability and validity of data
prepare test/calibration documentation that is accurate and complies with requirements
operate a wide range of equipment correctly and safely
apply all relevant enterprise procedures to ensure the quality and integrity of the services or data they provide
recognise opportunities for improvements to procedures.
Context of and specific resources for assessment
This unit of competency is to be assessed in the workplace or simulated workplace environment.
This unit of competency may be assessed with:
MSL925001A Analyse data and report results
MSL925002A Analyse measurements and estimate uncertainties.
Resources may include:
specialised calibration/test equipment, reference standards and materials and laboratory facilities
access to a library of calibration methods, procedures and equipment specifications
enterprise quality manual and procedures.
Method of assessment
The following assessment methods are suggested:
review of calibration results, uncertainty calculations and documentation completed by the candidate
feedback from supervisors and/or customers regarding quality of calibration services provided by the candidate
observation of the candidate conducting non-standard calibrations
oral or written questioning to check underpinning knowledge of non-standard calibration procedures.
In all cases, practical assessment should be supported by questions to assess underpinning knowledge and those aspects of competency which are difficult to assess directly.
Where applicable, reasonable adjustment must be made to work environments and training situations to accommodate ethnicity, age, gender, demographics and disability.
Access must be provided to appropriate learning and/or assessment support when required.
The language, literacy and numeracy demands of assessment should not be greater than those required to undertake the unit of competency in a work like environment.
This competency in practice
Industry representatives have provided the case studies below to illustrate the practical application of this unit of competency and to show its relevance in a workplace setting.
Background
Calibration technicians/specialists have the skills and knowledge to operate, maintain and calibrate a wide variety of complex test equipment and measuring instruments with limited guidance. They must remain abreast of technical and equipment advances, interpret complex technical information accurately and liaise with clients to clarify their needs. They must demonstrate high levels of initiative and concentration when performing technically demanding measurements, providing solutions for non-conforming work and when adjusting or repairing complex instruments. The calibration specialist's workload can be routine and repetitive. A perpetual back-log of work and the constant need to reduce turn-around-time to meet client demands coupled with enterprise productivity goals can induce stress and mental fatigue if not carefully managed. However, it is essential that personnel are able to perform tests and associated work tasks without undue pressure that might influence technical judgement if 'integrity of measurement' is to be retained.
Calibration (1)
A client has delivered a new model vibration transducer to the laboratory and would like a full test report on the item. A calibration technician assesses the job. They conclude that because the item is new to the industry, the laboratory will probably not have a documented calibration procedure. A quick ring around the company's other laboratories confirms that a procedure has not been written yet. They analyse the item's technical specifications and realise that although a generic procedure will suffice for most of the tests, it will have to be modified.
The technician reports these concerns to the supervisor who confirms that the client wants to know if the item meets the manufacturer's specifications. Approval is given to the technician to modify a previous procedure. The revised procedure is shown to the supervisor who checks each step and confirms the test is technically justified and all uncertainties have been calculated and documented.
The technician sets up the reference standards, confirms they are fully operational and within specification and begin the test. Each stage of the test is carefully monitored to ensure the data is correct and valid. On completion, another technician conducts the test and the data is compared. The supervisor is confident the test and data are valid and a report is generated, including a method validation summary for the laboratory's records.
Calibration (2)
A calibration technician is scheduled to calibrate a client's signal generator in accordance with the manufacturer's procedure. The technician reads the procedure and assembles all the required reference standards but notices the laboratory's reference frequency counter is not available because it has been sent away for calibration. The technician needs to substitute another instrument and so scans the other workbenches. They decide on a particular model and refer to the instrument's technical specifications to confirm that it has all the required ranges and is accurate enough. Convinced this item will do the job, the technician seeks and gains approval from the supervisor. There is no need to consult with the customer because the substitution will have no negative influence on the results. The technician completes the calibration in accordance with the procedure. In the final report, they document the details of the replacement equipment used in the test to ensure the repeatability of measurements and to comply with statutory regulations.
Replaces
| State Code | National Code | Title | Type |
|---|---|---|---|
| C7676 | PMLCAL500A | Perform non-standard calibrations | Unit of competency |
Replaced By
| State Code | National Code | Title | Type |
|---|---|---|---|
| AWO73 | MSL905001 | Perform non-standard calibrations | Unit of competency |
| State Code | National Code | Title | Type |
|---|---|---|---|
| W738 | MSL60109 | Advanced Diploma of Laboratory Operations | Qualification |
| W736 | MSL40109 | Certificate IV in Laboratory Techniques | Qualification |
| W737 | MSL50109 | Diploma of Laboratory Technology | Qualification |