Unit of competency Outline

Date retreived
22/07/2026 9:55 AM AWST

Whilst all efforts are made to provide accurate and timely information from the relevant source/documentation, please be aware that the information supplied may not be the most current version. The accuracy of the detail has not been confirmed by the Department and therefore should not be relied upon without first confirming the contents.

Install portable fire equipment

Install portable fire equipment

Unit of competency
National Code
CPCPFS2012A
State Code
D7436
TGA Status
Replaced
DTWD Status
Replaced
Current Release Number
1.00
Current Release Date
19/05/2011
State Implementation and Classification
Approved Date
10/07/2012
Field of Education
040327 - Plumbing
Original Release Date
10/07/2012
Nominal Hours
12
Description
This unit of competency specifies the outcomes required to install portable fire extinguishers, fire blankets and signage.
Notes
Elements and Performance Criteria
1. Prepare for work.
  • 1.1. Plans and specifications are obtained.
  • 1.2. Safety (OHS) requirements associated with the installation of portable fire equipment, and workplace environmental requirements, are adhered to throughout the work.
  • 1.3. Quality assurance requirements are identified and adhered to in accordance with workplace requirements.
  • 1.4. Tasks are planned and sequenced in conjunction with others involved in or affected by the work.
  • 1.5. Tools and equipment for installing portable fire equipment, including personal protective equipment, are selected and checked for serviceability.
  • 1.6. Work area is prepared to support efficient installation of portable fire equipment.
2. Identify installation requirements.
  • 2.1. Portable fire extinguisher requirements, including extinguishing agents and materials, are identified from job design criteria and specifications.
  • 2.2. Portable fire equipment is ordered and collected in accordance with workplace procedures.
  • 2.3. Portable fire equipment is checked for compliance with standards, docket and order form, and for acceptable condition.
3. Install portable fire equipment.
  • 3.1. Portable fire equipment is installed to authorities' requirements, and plans and specifications.
  • 3.2. Supports, fixings and signage are installed in accordance with plans, specifications and manufacturer instructions.
4. Clean up.
  • 4.1. Work area is cleared, with materials disposed of or recycled in accordance with state or territory statutory and regulatory authority legislation.
  • 4.2. Tools and equipment are cleaned, checked, maintained and stored in accordance with manufacturer recommendations and workplace procedures.
  • 4.3. Information is accessed and documentation completed in accordance with regulatory authorities and workplace requirements.
RANGE STATEMENT
The range statement relates to the unit of competency as a whole. It allows for different work environments and situations that may affect performance. Bold italicised wording, if used in the performance criteria, is detailed below. Essential operating conditions that may be present with training and assessment (depending on the work situation, needs of the candidate, accessibility of the item, and local industry and regional contexts) may also be included.
Safety (OHS) is to be in accordance with commonwealth, state and territory legislation and regulations and may include:
handling of materials
hazard control
protective clothing and equipment prescribed under legislation, regulations and workplace policies and practices
safe operating procedures, including recognising and preventing hazards associated with:
hazardous materials and substances
service lines
surrounding structures and facilities
trip hazards
use of tools and equipment
work site visitors and the public
working at heights
working in proximity to others
use of firefighting equipment
use of first aid equipment
workplace environment and safety.
Environmental requirements cover water quality management and may include:
clean-up protection
waste management.
Quality assurance requirements may include:
Australian standards
Environment Protection Authority (EPA)
internal company quality assurance policy and risk management strategy
International Standards Organisation
site safety plan
workplace operations and procedures.
Tools and equipment may include:
hand and power tools.
Extinguishing agents for portable fire extinguishers include:
carbon dioxide gases
dry chemical and chemical reaction suppression systems
foam.
Materials may include:
portable fire extinguishers
supports and brackets.
Statutory and regulatory authorities include:
state or territory statutory authority
statutory plumbing authority.
Information may include:
charts and hand drawings
diagrams or sketches and graphics
instructions issued by authorised organisational or external personnel
manufacturer specifications and instructions
maps
material safety data sheets (MSDS)
memos
National Fire Protection Association (NFPA) and Factory Mutual Performance based codes of practice
organisation work specifications and requirements
regulatory and legislative requirements, particularly those pertaining to:
building codes
OHS and environmental requirements
plumbing regulations
relevant Australian standards
safe work procedures relating to installing portable fire equipment
signage
verbal, written and graphical instructions
work bulletins
work schedules, plans and specifications.
EVIDENCE GUIDE
The evidence guide provides advice on assessment and must be read in conjunction with the performance criteria, required skills and knowledge, range statement and the Assessment Guidelines for the Training Package.
Overview of assessment
This unit of competency could be assessed in the workplace or a close simulation of the workplace environment providing that simulated or project-based assessment techniques fully replicate plumbing and services workplace conditions, materials, activities, responsibilities and procedures.
Critical aspects for assessment and evidence required to demonstrate competency in this unit
A person who demonstrates competency in this unit must be able to provide evidence of:
locating, interpreting and applying relevant information, standards and specifications to install portable fire equipment
applying safety requirements throughout the work sequence, including the use of personal protective clothing and equipment
as a minimum the ability to, given the plans and specifications for an office complex requiring the installation of water, carbon dioxide (CO 2) and dry chemical portable fire extinguishers, fire blankets and signage, install the appliances, ensuring:
correct identification of requirement, location and installation of the extinguishers
correct selection and use of appropriate processes, tools and equipment
completing all work to specification
compliance with regulations, standards and organisational quality procedures and processes
communicating and working effectively and safely with others.
Context of and specific resources for assessment
This competency is to be assessed using standard and authorised work practices, safety requirements and environmental constraints.
Assessment of essential underpinning knowledge will usually be conducted in an off-site context.
Assessment is to comply with relevant regulatory or Australian standards' requirements.
Resource implications for assessment include:
an induction procedure and requirement
realistic tasks or simulated tasks covering the minimum task requirements
relevant specifications and work instructions
tools and equipment appropriate to applying safe work practices
support materials appropriate to activity
workplace instructions relating to safe working practices and addressing hazards and emergencies
material safety data sheets
research resources, including industry related systems information.
Reasonable adjustments for people with disabilities must be made to assessment processes where required. This could include access to modified equipment and other physical resources, and the provision of appropriate assessment support.
Method of assessment
Assessment methods must:
satisfy the endorsed Assessment Guidelines of the Construction, Plumbing and Services Training Package
include direct observation of tasks in real or simulated work conditions, with questioning to confirm the ability to consistently identify and correctly interpret the essential underpinning knowledge required for practical application
reinforce the integration of employability skills with workplace tasks and job roles
confirm that competency is verified and able to be transferred to other circumstances and environments.
Validity and sufficiency of evidence requires that:
competency will need to be demonstrated over a period of time reflecting the scope of the role and the practical requirements of the workplace
where the assessment is part of a structured learning experience the evidence collected must relate to a number of performances assessed at different points in time and separated by further learning and practice, with a decision on competency only taken at the point when the assessor has complete confidence in the person's demonstrated ability and applied knowledge
all assessment that is part of a structured learning experience must include a combination of direct, indirect and supplementary evidence.
Assessment processes and techniques should as far as is practical take into account the language, literacy and numeracy capacity of the candidate in relation to the competency being assessed.
Supplementary evidence of competency may be obtained from relevant authenticated documentation from third parties, such as existing supervisors, team leaders or specialist training staff.
Replaces
State Code National Code Title Type
W9666 CPCPFS2002A Install portable fire equipment Unit of competency
Replaced By
State Code National Code Title Type
WF869 CPCPFS2022A Install portable fire equipment Unit of competency
State Code National Code Title Type
D415 CPC32811 Certificate III in Fire Protection Qualification