Whilst all efforts are made to provide accurate and timely information from the relevant source/documentation, please be aware that the information supplied may not be the most current version. The accuracy of the detail has not been confirmed by the Department and therefore should not be relied upon without first confirming the contents.

Assess and improve sedimentation processes

Assess and improve sedimentation processes

Unit of competency
National Code
NWPTRT032
State Code
AVY16
TGA Status
Replaced
DTWD Status
Replaced
Current Release Number
1.00
Current Release Date
07/12/2015
State Implementation and Classification
Approved Date
15/04/2016
Field of Education
030907 - Water And Sanitary Engineering
Original Release Date
15/04/2016
Nominal Hours
60
Description
This unit describes the skills required to evaluate system performance and investigate and report on the optimisation of sedimentation and clarification processes.This unit applies to those working as technical staff with responsibility for optimising sedimentation and clarification processes in water and wastewater treatment plants. This role may be performed as a single operator, or as part of a team with some responsibility for team coordination and supervision, depending on the size of the treatment plant.The skills and knowledge described in this unit must be applied within the legislative, regulatory and policy environment in which they are carried out. Organisational policies and procedures must be consulted and adhered to.Those undertaking this unit would work under indirect supervision, while performing complex tasks, within a familiar context.No licensing, legislative or certification requirements apply to unit at the time of publication.
Notes
Elements and Performance Criteria
1. Assess sedimentation and clarification process performance
  • 1.1 Review existing process performance data.
  • 1.2 Identify the impact of changing incoming water quality on sedimentation and clarification processes in a range of conditions.
  • 1.3 Identify any additional sampling and testing required for valid evaluation of current process performance.
2. Investigate sedimentation and clarification assets
  • 2.1 Review existing fault reports and other plant asset information.
  • 2.2 Investigate the operational status of plant components with reference to manufacturer and plant designer specifications.
  • 2.3 Carry out investigations to identify potential deficiencies.
3. Investigate process optimisation
  • 3.1 Review relevant fault and incident reports and remedial actions taken.
  • 3.2 Investigate potential changes to operational processes to identify possible optimisation strategies.
4. Plan process optimisation
  • 4.1 Determine plant configuration and revised operational processes for process optimisation.
  • 4.2 Plan a trial to test the performance of the determined optimisation options.
  • 4.3 Compile a report making recommendations on optimisation options.
No information
No information
Replaces
State Code National Code Title Type
D4820 NWP408A Investigate and plan the optimisation of sedimentation and clarification processes Unit of competency
Replaced By
State Code National Code Title Type
OCW45 NWPTRT064 Assess and improve sedimentation processes Unit of competency
State Code National Code Title Type
AYX2 NWP40615 Certificate IV in Water Industry Treatment Qualification