Whilst all efforts are made to provide accurate and timely information from the relevant source/documentation, please be aware that the information supplied may not be the most current version. The accuracy of the detail has not been confirmed by the Department and therefore should not be relied upon without first confirming the contents.
Operate and monitor water quality monitoring systems
Operate and monitor water quality monitoring systems
Unit of competency
National Code
UEPOPS109
UEPOPS109
State Code
ODY67
ODY67
TGA Status
Current
Current
DTWD Status
Approved
Approved
State Implementation and Classification
Approved Date
14/04/2023
Field of Education
030717 - Plant And Machine Operations
Original Release Date
14/04/2023
Nominal Hours
27
Description
This unit involves the skills and knowledge required to operate and monitor water quality monitoring systems in a power generation facility. These systems include all analytical devices used to monitor process chemical conditions. Water quality refers to thechemical,physical,biological and/or radiologicalcharacteristics ofwater. Water quality is a crucial factor for avoiding corrosion and scaling of turbines, boilers and pipes in power generating plant.Competency in this unit requires the ability to plan work, operate water quality monitoring systems plant, test water quality monitoring systems plant, analyse water quality monitoring systems plant faults, monitor and inspect water quality monitoring systems plant, and complete all documentation. Individuals will, in general, work under supervision, in a power generation facility as an operator. Power generation plant operators are trained and authorised to isolate, prepare plant and issue permits to work.No licensing, legislative or certification requirements apply to this unit at the time of publication.
Notes
Elements and Performance Criteria
1 Plan and prepare work
- 1.1 Work health and safety (WHS)/occupational health and safety (OHS) regulations, legislative requirements, codes of practice, manufacturers’ recommendations and specifications, environmental requirements and workplace procedures are identified, applied and monitored
- 1.2 Work requirements are identified from relevant personnel and documentation in accordance with workplace procedures
- 1.3 Documentation to determine water quality monitoring system plant status is assessed and evaluated in accordance with workplace procedures
- 1.4 Water quality monitoring system plant inspection is carried out in accordance with manufacturers' recommendations and specifications, and workplace procedures
- 1.5 Water quality monitoring system plant operational prerequisites are established in accordance with manufacturers' recommendations and specifications, and workplace procedures
- 1.6 Sequence for recommissioning of water quality monitoring system plant is determined in accordance with workplace procedures
2 Operate water quality monitoring system plant
- 2.1 Water quality monitoring system plant is operated in accordance with manufacturers' recommendations and specifications, and workplace procedures
- 2.2 Water quality monitoring system plant is monitored and observed to detect deviations from normal operating conditions in accordance with workplace procedures
- 2.3 Corrective actions are taken to rectify abnormalities in water quality monitoring system plant in accordance with manufacturers' recommendations and specifications, and workplace procedures
3 Test water quality monitoring system plantoperation
- 3.1 Operational tests are performed in accordance with workplace procedures
- 3.2 Water quality monitoring system plant is observed for correct operational response in accordance with workplace procedures
- 3.3 Water quality monitoring system plant is returned to required operational status upon completion of testing in accordance with workplace procedures
4 Analyse water quality monitoring systemplant conditions
- 4.1 Cause of abnormal water quality monitoring system plant conditions are identified by analysing technical and operational information in accordance with workplace procedures
- 4.2 Water quality monitoring system plant integrity and personnel safety is maintained in consultation with relevant personnel and technical and operational documentation in accordance with workplace procedures
5 Monitor and inspect water quality monitoring system plant
- 5.1 Water quality monitoring system plant is monitored and inspected for normal operation and to detect deviations in accordance with workplace procedures
- 5.2 Relevant personnel are notified when defects are detected in accordance with workplace procedures
6 Complete documentation
- 6.1 Water quality monitoring systems plant problems, movements, abnormalities and status are reported in accordance with workplace procedures
- 6.2 Documentation is updated in accordance with workplace procedures
No information
No information
Replaces
| State Code | National Code | Title | Type |
|---|---|---|---|
| OAH03 | UEPOPS325 | Operate and monitor water quality monitoring systems | Unit of competency |
| State Code | National Code | Title | Type |
|---|---|---|---|
| BHQ7 | UEP30122 | Certificate III in ESI Generation | Qualification |
| BIO0 | UEP30322 | Certificate III in ESI Generation | Qualification |
| BHQ2 | UEP40122 | Certificate IV in ESI Generation | Qualification |
| BHP9 | UEP50122 | Diploma of ESI Generation | Qualification |
| BHQ3 | UEP20222 | Certificate II in Remote Area Essential Service | Qualification |