Unit of competency Outline

Date retreived
22/07/2026 11:00 PM AWST

Whilst all efforts are made to provide accurate and timely information from the relevant source/documentation, please be aware that the information supplied may not be the most current version. The accuracy of the detail has not been confirmed by the Department and therefore should not be relied upon without first confirming the contents.

Conduct compliance inspection of LV electrical installations with demand exceeding 100 A per phase

Conduct compliance inspection of LV electrical installations with demand exceeding 100 A per phase

Unit of competency
National Code
UEEEL0029
State Code
OBZ07
TGA Status
Current
DTWD Status
Approved
Current Release Number
2.00
Current Release Date
29/11/2024
State Implementation and Classification
Approved Date
12/07/2021
Field of Education
031313 - Electrical Fitting, Electrical Mechanics
Original Release Date
12/07/2021
Nominal Hours
36
Description
This unit involves the skills and knowledge required to conduct compliance inspection of low voltage (LV) electrical installation with demand exceeding 100 ampere (A) per phase.It includes preparing and conduction compliance inspection, and actioning and reporting on findings.The skills and knowledge described in this unit require a licence or permit to practice in the workplace where work is carried out on electrical installations which are designed to operate at voltages greater than 50 volt (V) alternating current (a.c.) or 120 V direct current (d.c.).Competency development activities in this unit are subject to regulations directly related to licensing. Additional and/or other conditions may apply in some jurisdictions subject to regulations related to electrical work. Practice in the workplace and during training is also subject to work health and safety (WHS)/occupational health and safety (OHS) regulations.
Notes
Elements and Performance Criteria
1 Prepare to conduct compliance inspection
  • 1.1 WHS/OHS procedures for a given work area are identified, obtained and applied
  • 1.2 WHS/OHS risk control measures and procedures in preparation for the work are followed
  • 1.3 WHS/OHS hazards not previously identified are noted and risk control measures are implemented in consultation with appropriate person/s
  • 1.4 Installation documentation and relevant industry standards are reviewed and applied
  • 1.5 Appropriate person/s is consulted to ensure the work is coordinated effectively with others
  • 1.6 Tools, equipment and testing devices to verify compliance are obtained and checked for operation and safety in accordance with workplace procedures
2 Conduct compliance inspection
  • 2.1 WHS/OHS risk control measures and workplace procedures for carrying out work are followed
  • 2.2 Need to test and measure live electrical work is determined in accordance with WHS/OHS requirements and workplace procedures
  • 2.3 Circuits/machines/plant are checked and isolated in accordance with WHS/OHS requirements and workplace procedures
  • 2.4 Inspection of the mains and main switchboard is conducted of protection metering earthing circuit arrangements and markings in accordance with relevant industry standards
  • 2.5 Inspection of circuits is conducted for compliance of the installed wiring accessories switchgear/control gear and current-using devices in accordance with relevant industry standards
  • 2.6 Electrical equipment compliance with relevant safety requirements and industry standards is obtained from appropriate person/s
  • 2.7 Inspection is conducted to verify compliance of earthing insulation polarity circuit connections and operation of residual current devices (RCDs) in accordance with relevant industry standards
  • 2.8 Fault-loop impedance is determined as being sufficiently low by testing calculation and compliance with arrangement of the installation in accordance with relevant industry standards
  • 2.9 Unplanned events are responded to in accordance with workplace procedures in a manner that minimises risk to personnel and equipment
3 Act and report on inspection findings
  • 3.1 WHS/OHS work completion risk control measures and procedures are followed
  • 3.2 Non-compliance defects are identified and documented in accordance with relevant industry standards and workplace procedures
  • 3.3 Actions for non-compliance defects within the scope of inspection responsibilities are in accordance with workplace procedures and relevant industry standards
  • 3.4 Inspection report is completed and issued to appropriate person/s in accordance with workplace procedures and relevant industry standards
No information
No information