Unit of competency Outline

Date retreived
22/07/2026 2:45 PM AWST

Whilst all efforts are made to provide accurate and timely information from the relevant source/documentation, please be aware that the information supplied may not be the most current version. The accuracy of the detail has not been confirmed by the Department and therefore should not be relied upon without first confirming the contents.

Diagnose and rectify faults in recording and replay equipment

Diagnose and rectify faults in recording and replay equipment

Unit of competency
National Code
UEEEC0025
State Code
OCB90
TGA Status
Current
DTWD Status
Approved
Current Release Number
1.00
Current Release Date
05/10/2020
State Implementation and Classification
Approved Date
12/07/2021
Field of Education
031317 - Electronic Equipment Servicing
Original Release Date
12/07/2021
Nominal Hours
54
Description
This unit involves the skills and knowledge required to diagnose and rectify faults in recording and replay equipment.It includes fault finding and repair of faults in recording and replay equipment. It also includes working safely, applying logical diagnostic methods and replay apparatus components, rectifying faults, safety and functional testing, and completing the necessary service documentation.Permits may be required for some work environments, such as confined spaces, working aloft, near live electrical apparatus and site rehabilitation.No licensing, legislative or certification requirements apply to this unit at the time of publication.
Notes
Elements and Performance Criteria
1 Prepare to diagnose and rectify recording and replay equipment faults
  • 1.1 Work health and safety (WHS)/occupational health and safety (OHS) requirements and workplace procedures for a given work area are identified and applied
  • 1.2 WHS/OHS risk control measures and workplace procedures are followed in preparation for recording and replay equipment work
  • 1.3 Safety hazards which have not previously been identified are risk assessed, documented and risk control measures devised and implemented in consultation with appropriate person/s
  • 1.4 Extent of fault is determined from reports, documentation and from discussions with appropriate person/s
  • 1.5 Appropriate person/s is consulted to ensure the work is coordinated effectively with others involved on the work site
  • 1.6 Tools, equipment and testing devices needed to diagnose faults are obtained in accordance with workplace procedures and checked for correct operation and safety
2 Diagnose and rectify recording and replay equipment faults
  • 2.1 WHS/OHS risk control measures and workplace procedures for carrying out recording and replay equipment work are followed
  • 2.2 Need to test and measure live work is determined in accordance with WHS/OHS requirements and, as required, conducted in accordance with workplace safety procedures
  • 2.3 Circuits/machines/plant are checked and isolated in accordance with WHS/OHS requirements and workplace procedures
  • 2.4 Logical diagnostic methods are applied to diagnose recording and replay apparatus faults using measurements of circuit operating parameters in accordance with recording and replay apparatus operating specifications
  • 2.5 Suspected fault scenarios are tested as being the source of recording and replay apparatus problems in accordance with workplace procedures and relevant industry standards
  • 2.6 Faults in the electronic components of the recording and replay apparatus are rectified to recording and replay apparatus operation and industry standards
  • 2.7 Apparatus are inspected and tested to verify that they operate as intended and to specified requirements
  • 2.8 Unplanned situations are responded to in accordance with workplace procedures, discussions with appropriate person/s and consistent with job specifications and requirements in a manner that minimises risk to personnel and equipment
  • 2.9 Diagnosis and rectification activities are carried out efficiently without waste of materials or damage to apparatus, the surrounding environment or services using sustainable energy practices
3 Complete and report fault diagnosis and rectification activities
  • 3.1 WHS/OHS work completion risk control measures and workplace procedures are followed
  • 3.2 Worksite is made safe in accordance with workplace safety procedures
  • 3.3 Rectification of faults is documented in accordance with workplace procedures
  • 3.4 Appropriate person/s is notified in accordance with workplace procedures that recording and replay apparatus faults have been rectified
No information
No information
Replaces
State Code National Code Title Type
WC602 UEENEEH177A Diagnose and rectify faults in recording and replay equipment Unit of competency